Literature DB >> 22087411

A short-term clinical study of marginal bone level change around microthreaded and platform-switched implants.

Hee-Jung Yun1, Jung-Chul Park, Jeong-Ho Yun, Ui-Won Jung, Chang-Sung Kim, Seong-Ho Choi, Kyoo-Sung Cho.   

Abstract

PURPOSE: The marginal bone levels around implants following restoration are used as a reference for evaluating implant success and survival. Two design concepts that can reduce crestal bone resorption are the microthread and platform-switching concepts. The aims of this study were to analyze the placement of microthreaded and platform-switched implants and their short-term survival rate, as well as the level of bone around the implants.
METHODS: The subjects of this study were 27 patients (79 implants) undergoing treatment with microthreaded and platform-switched implants between October 2008 and July 2009 in the Dental Hospital of Yonsei University Department of Periodontology. The patients received follow-up care more than 6 months after the final setting of the prosthesis, at which time periapical radiographs were taken. The marginal bone level was measured from the reference point to the lowest observed point of contact between the marginal bone and the fixture. Comparisons were made between radiographs taken at the time of fixture installation and those taken at the follow-up visit.
RESULTS: During the study period (average of 11.8 months after fixture installation and 7.4 months after the prosthesis delivery), the short-term survival rate of microthreaded and platform-switched implants was 100% and the marginal bone loss around implants was 0.16±0.08 mm, the latter of which is lower than the previously reported values.
CONCLUSIONS: This short-term clinical study has demonstrated the successful survival rates of a microthread and platform-switched implant system, and that this system is associated with reduced marginal bone loss.

Entities:  

Keywords:  Alveolar bone loss; Dental implants

Year:  2011        PMID: 22087411      PMCID: PMC3213231          DOI: 10.5051/jpis.2011.41.5.211

Source DB:  PubMed          Journal:  J Periodontal Implant Sci        ISSN: 2093-2278            Impact factor:   2.614


  32 in total

1.  Some clinical factors related to rate of resorption of residual ridges. 1962.

Authors:  D A Atwood
Journal:  J Prosthet Dent       Date:  2001-08       Impact factor: 3.426

2.  Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels.

Authors:  Richard J Lazzara; Stephan S Porter
Journal:  Int J Periodontics Restorative Dent       Date:  2006-02       Impact factor: 1.840

3.  Influence of the tooth- and implant-side marginal bone level on the interproximal papilla dimension in a single implant with a microthread, conical seal, and platform-switched design.

Authors:  Hee-Jun Kwon; Dong-Won Lee; Kwang-Ho Park; Chong-Kwan Kim; Ik-Sang Moon
Journal:  J Periodontol       Date:  2009-09       Impact factor: 6.993

4.  Evaluation of postsurgical crestal bone levels adjacent to non-submerged dental implants.

Authors:  U Brägger; U Häfeli; B Huber; C H Hämmerle; N P Lang
Journal:  Clin Oral Implants Res       Date:  1998-08       Impact factor: 5.977

5.  Osseointegrated implants in edentulous jaws: a 2-year longitudinal study.

Authors:  J Ahlqvist; K Borg; J Gunne; H Nilson; M Olsson; P Astrand
Journal:  Int J Oral Maxillofac Implants       Date:  1990       Impact factor: 2.804

6.  Tissue characteristics at microthreaded implants: an experimental study in dogs.

Authors:  Ingemar Abrahamsson; Tord Berglundh
Journal:  Clin Implant Dent Relat Res       Date:  2006       Impact factor: 3.932

7.  Intra-osseous anchorage of dental prostheses. I. Experimental studies.

Authors:  P I Brånemark; R Adell; U Breine; B O Hansson; J Lindström; A Ohlsson
Journal:  Scand J Plast Reconstr Surg       Date:  1969

Review 8.  The long-term efficacy of currently used dental implants: a review and proposed criteria of success.

Authors:  T Albrektsson; G Zarb; P Worthington; A R Eriksson
Journal:  Int J Oral Maxillofac Implants       Date:  1986       Impact factor: 2.804

9.  Tissue integration of non-submerged implants. 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants.

Authors:  D Buser; H P Weber; N P Lang
Journal:  Clin Oral Implants Res       Date:  1990-12       Impact factor: 5.977

10.  Different types of inflammatory reactions in peri-implant soft tissues.

Authors:  I Ericsson; L G Persson; T Berglundh; C P Marinello; J Lindhe; B Klinge
Journal:  J Clin Periodontol       Date:  1995-03       Impact factor: 8.728

View more
  5 in total

1.  The influence of thread geometry on implant osseointegration under immediate loading: a literature review.

Authors:  Hyo-Sook Ryu; Cheol Namgung; Jong-Ho Lee; Young-Jun Lim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

2.  Analysis of micromovements and peri-implant stresses and strains around ultra-short implants - A three-dimensional finite-element method study.

Authors:  Nida Sumra; Shrikar Desai; Rohit Kulshrestha; Khusbhu Mishra; Raahat Vikram Singh; Prachi Gaonkar
Journal:  J Indian Soc Periodontol       Date:  2021-07-01

3.  Novel expandable short dental implants in situations with reduced vertical bone height-technical note and first results.

Authors:  Waldemar Reich; Ramona Schweyen; Christian Heinzelmann; Jeremias Hey; Bilal Al-Nawas; Alexander Walter Eckert
Journal:  Int J Implant Dent       Date:  2017-10-30

4.  Clinical Performance of Short Expandable Dental Implants for Oral Rehabilitation in Highly Atrophic Alveolar Bone: 3-year Results of a Prospective Single-Center Cohort Study.

Authors:  Waldemar Reich; Ramona Schweyen; Jeremias Hey; Sven Otto; Alexander Walter Eckert
Journal:  Medicina (Kaunas)       Date:  2020-07-03       Impact factor: 2.430

5.  Current results and trends in platform switching.

Authors:  Hadi Salimi; Omid Savabi; Farahnaz Nejatidanesh
Journal:  Dent Res J (Isfahan)       Date:  2011-12
  5 in total