Prevention of bacterial leakage into and from prefabricated screw-retained crowns on implants in vitro.

C E Besimo1, J S Guindy, D Lewetag, J Meyer.   

Abstract

Previous in vitro studies have shown that a mean gap of less than 4 microns between prefabricated crowns and implants of the Ha-Ti implant system is not a barrier to infiltration by Staphylococcus aureus. These studies confirmed earlier in vivo work showing that a multitude of oral microorganisms could colonize and infiltrate these gaps. In the present investigation, 30 Ha-Ti implant-crown assemblies were tested for bacterial leakage after the gaps were sealed with the chlorhexidine-containing varnish Cervitec. S. aureus leakage into the totally submerged test specimens was detected in 1 of 5 samples incubated for 4 weeks, while no leakage was detected in specimens incubated for 3, 5, 6, 7, and 8 weeks. When the sealed test specimens were partially submerged (that is, excluding the screw hole of the crown) and incubated for 3 to 11 weeks, none of the internal surfaces of the 30 test specimens manifested contamination. The clinical relevance of gap sealing in maintaining inflammation-free marginal mucosa and in achieving clinically successful treatment of peri-implantitis has yet to be determined.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10531737

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  10 in total

1.  Molecular leakage at implant-abutment connection--in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration.

Authors:  Sönke Harder; Birka Dimaczek; Yaha Açil; Hendrik Terheyden; Sandra Freitag-Wolf; Matthias Kern
Journal:  Clin Oral Investig       Date:  2009-07-23       Impact factor: 3.573

2.  Microgap and microleakage of a hybrid connection platform-switched implant system in the absence or presence of a silicone-based sealing agent.

Authors:  Pedro Ferrás Fernandes; Liliana Grenho; Maria Helena Fernandes; João Carlos Sampaio-Fernandes; Pedro Sousa Gomes
Journal:  Odontology       Date:  2021-08-27       Impact factor: 2.634

3.  Micro-leakage at the implant-abutment interface with different tightening torques in vitro.

Authors:  João Paulo da Silva-Neto; Marcel Santana Prudente; Thiago de Almeida Prado Naves Carneiro; Mauro Antônio de Arruda Nóbilo; Mario Paulo Amante Penatti; Flávio Domingues das Neves
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

4.  Development of a new quantitative gas permeability method for dental implant-abutment connection tightness assessment.

Authors:  Jacques-Henri Torres; Michael Mechali; Olivier Romieu; Paul Tramini; Sylvie Callas; Frédéric Jg Cuisinier; Bernard Levallois
Journal:  Biomed Eng Online       Date:  2011-04-14       Impact factor: 2.819

5.  Leakage evaluation of original and compatible implant-abutment connections: In vitro study using Rhodamine B.

Authors:  Antoine Berberi; George Tehini; Khaldoun Rifai; Farah Bou Nasser Eddine; Bassam Badran; Haidar Akl
Journal:  J Dent Biomech       Date:  2014-08-11

6.  Bone-level implants placed in the anterior maxilla: an open-label, single-arm observational study.

Authors:  EnFeng Gao; Wei-Hong Hei; Jong-Chul Park; KangMi Pang; Sun Kyung Kim; Bongju Kim; Soung-Min Kim; Jong-Ho Lee
Journal:  J Periodontal Implant Sci       Date:  2017-10-30       Impact factor: 2.614

7.  The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study.

Authors:  Mehrak Amjadi; Azadeh Khajavi; Navid Youssefi; Negar Barjini; Zahra Kazemi
Journal:  J Indian Prosthodont Soc       Date:  2021 Oct-Dec

8.  In Vitro Bacterial Leakage at the Implant-Abutment Connection of Two Dental Implant Systems with Internal Connection.

Authors:  Azadeh Khajavi; Shabnam Mohseni; Amir Peymani; Mehrak Amjadi
Journal:  Front Dent       Date:  2020-12-08

9.  Antibacterial Peptide-Based Gel for Prevention of Medical Implanted-Device Infection.

Authors:  Mihaela Mateescu; Sébastien Baixe; Tony Garnier; Loic Jierry; Vincent Ball; Youssef Haikel; Marie Hélène Metz-Boutigue; Michel Nardin; Pierre Schaaf; Olivier Etienne; Philippe Lavalle
Journal:  PLoS One       Date:  2015-12-14       Impact factor: 3.240

10.  Effects of Aging Torque Controllers on Screw Tightening Force and Bacterial Micro-Leakage on the Implant-Abutment Complex.

Authors:  Yousef Jiries; Tamar Brosh; Shlomo Matalon; Vladimir Perlis; Zeev Ormianer
Journal:  Materials (Basel)       Date:  2022-01-14       Impact factor: 3.623

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.