Literature DB >> 10530846

Poor eight-year survival of cemented zirconia-polyethylene total hip replacements.

J Allain1, S Le Mouel, D Goutallier, M C Voisin.   

Abstract

Between January 1988 and January 1991 we performed 100 consecutive cemented total hip replacements using a zirconia head, a titanium alloy stem and a polyethylene cup. We reviewed 78 of these hips in 61 patients in detail at a mean of 5.8 years (1 to 9). Aseptic loosening was seen in 11 hips (14%). Eight needed revision. In total, 37 cups (47.5%) showed radiolucent lines, all at the cement-bone interface, with 18 (23%) involving all the interface. Of the 78 femoral implants, 17 (21.7%) showed radiolucent lines, and two, which had a complete line of more than 1 mm thick, definite endocortical osteolyses. There was also an abnormally high incidence of osteolysis of more than 2 mm at the calcar. Survivorship analysis showed that only 63% were in situ at eight years. These worrying results led us to abandon the use of zirconia heads, since at the same hospital, using the same femoral stem, cement and polyethylene cup, but with alumina femoral heads, the survival rate was 93% at nine years. We discuss the possible reasons for the poor performance of zirconia ceramic.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10530846     DOI: 10.1302/0301-620x.81b5.9454

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  9 in total

Review 1.  Manufacturers affect clinical results of THA with zirconia heads: a systematic review.

Authors:  Hiroyuki Yoshitomi; Satoru Shikata; Hiromu Ito; Takeo Nakayama; Takashi Nakamura
Journal:  Clin Orthop Relat Res       Date:  2009-01-31       Impact factor: 4.176

2.  Similar wear in total hip arthroplasties with metallic or zirconia femoral heads.

Authors:  Randy M Cohn; Alejandro González Della Valle; Margaret Peterson; Charles N Cornell
Journal:  HSS J       Date:  2008-07-15

3.  Charnley-Kerboull total hip arthroplasty combining zirconia on polyethylene. A minimum eight-year follow-up prospective study.

Authors:  Jean Langlois; Samer El Hage; Faouzi Madi; Jean-Pierre Courpied; Marcel Kerboull; Moussa Hamadouche
Journal:  Int Orthop       Date:  2013-01-31       Impact factor: 3.075

4.  Clinical comparison of polyethylene wear with zirconia or cobalt-chromium femoral heads.

Authors:  Maiken Stilling; Kjeld Anton Nielsen; Kjeld Søballe; Ole Rahbek
Journal:  Clin Orthop Relat Res       Date:  2009-03-27       Impact factor: 4.176

5.  High 10-year survival rate with an anatomic cementless stem (SPS).

Authors:  Elhadi Sariali; Alexandre Mouttet; Philippe Mordasini; Yves Catonné
Journal:  Clin Orthop Relat Res       Date:  2012-03-09       Impact factor: 4.176

Review 6.  Recent updates for biomaterials used in total hip arthroplasty.

Authors:  Chang Yong Hu; Taek-Rim Yoon
Journal:  Biomater Res       Date:  2018-12-05

7.  No Difference in Conventional Polyethylene Wear Between Yttria-stabilized Zirconia and Cobalt-chromium-molybdenum Femoral Heads at 10 Years.

Authors:  Todd A Morrison; Rebecca D Moore; Jia Meng; Clare M Rimnac; Matthew J Kraay
Journal:  HSS J       Date:  2017-10-13

8.  Two-piece zirconia implants supporting all-ceramic crowns: a prospective clinical study.

Authors:  Norbert Cionca; Nada Müller; Andrea Mombelli
Journal:  Clin Oral Implants Res       Date:  2014-03-26       Impact factor: 5.977

9.  Are PEEK-on-Ceramic Bearings an Option for Total Disc Arthroplasty? An In Vitro Tribology Study.

Authors:  Ryan Siskey; Lauren Ciccarelli; Melissa K C Lui; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2016-11       Impact factor: 4.176

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.