Literature DB >> 10525517

Stent implantation for aortic coarctation and recoarctation.

A G Magee1, G Brzezinska-Rajszys, S A Qureshi, E Rosenthal, M Zubrzycka, J Ksiazyk, M Tynan.   

Abstract

OBJECTIVE: To determine the early results of balloon expandable stent implantation for aortic coarctation or recoarctation.
DESIGN: Prospective observational study.
SETTING: Two paediatric cardiology tertiary referral centres. PATIENTS: 17 patients, median age 17 years (range 4.4 to 45) and median weight 61 kg (17 to 92). Six had native aortic coarctation and 11 had aortic recoarctation; 14 had upper limb systolic hypertension. Of those with recoarctation, eight had had at least one previous balloon dilatation attempt and two of these patients also had further surgical interventions. INTERVENTION: Balloon expandable Palmaz iliac stent implantation. MAIN OUTCOME MEASURES: Systolic pressures gradients, minimum aortic diameter, upper limb blood pressures, and incidence of aneurysm formation.
RESULTS: 18 stents were implanted during 18 procedures in the 17 patients. Mean peak systolic pressure gradient fell from 26 mm Hg (95% confidence interval (CI), 21 to 31 mm Hg) before to 5 mm Hg (2 to 8 mm Hg) after stent implantation (p < 0.001), and mean minimum aortic diameter increased from 7 mm (95% CI, 6 to 8 mm) before to 11.3 mm (10 to 12.6 mm) after implantation (p < 0.001). Complications occurred in five patients (bleeding in two, stent migration in two, and aneurysm formation in one). Two patients remained borderline hypertensive and eight were receiving antihypertensive treatment at most recent assessment.
CONCLUSIONS: Stent implantation for aortic recoarctation and native coarctation gives good immediate results. Careful follow up is necessary to evaluate complications and the long term effect on blood pressure.

Entities:  

Mesh:

Year:  1999        PMID: 10525517      PMCID: PMC1760772          DOI: 10.1136/hrt.82.5.600

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  32 in total

1.  Perioperative complications in combined aortic valve replacement and extraanatomic ascending-descending bypass.

Authors:  K Pethig; T Wahlers; S Tager; H G Borst
Journal:  Ann Thorac Surg       Date:  1996-06       Impact factor: 4.330

2.  Implantation of balloon-expandable stents for coarctation of the aorta: implantation data and short-term results.

Authors:  Z R Bulbul; E Bruckheimer; J C Love; J T Fahey; W E Hellenbrand
Journal:  Cathet Cardiovasc Diagn       Date:  1996-09

3.  Acute results of balloon angioplasty of native coarctation versus recurrent aortic obstruction are equivalent. Valvuloplasty and Angioplasty of Congenital Anomalies (VACA) Registry Investigators.

Authors:  B W McCrindle; T K Jones; W R Morrow; D J Hagler; T R Lloyd; S Nouri; L A Latson
Journal:  J Am Coll Cardiol       Date:  1996-12       Impact factor: 24.094

4.  Dilatation mechanism of balloon angioplasty in children: assessment by angiography and intravascular ultrasound.

Authors:  T Ino; M Kishiro; M Okubo; K Akimoto; K Nishimoto; K Yabuta; S Kawasaki; Y Hosoda
Journal:  Cardiovasc Intervent Radiol       Date:  1998 Mar-Apr       Impact factor: 2.740

5.  Intravascular ultrasound assessment of regional aortic wall stiffness, distensibility, and compliance in patients with coarctation of the aorta.

Authors:  J Xu; T Shiota; R Omoto; X Zhou; S Kyo; M Ishii; M J Rice; D J Sahn
Journal:  Am Heart J       Date:  1997-07       Impact factor: 4.749

6.  Stent redilation in canine models of congenital heart disease: pulmonary artery stenosis and coarctation of the aorta.

Authors:  A M Mendelsohn; P C Dorostkar; C P Moorehead; F M Lupinetti; P I Reynolds; A Ludomirsky; T R Lloyd; K Heidelberger; R H Beekman
Journal:  Cathet Cardiovasc Diagn       Date:  1996-08

7.  Late development of dissecting aneurysm following balloon angioplasty of native aortic coarctation.

Authors:  U Aydogan; A Dindar; L Gurgan; T Cantez
Journal:  Cathet Cardiovasc Diagn       Date:  1995-11

8.  Five- to nine-year follow-up results of balloon angioplasty of native aortic coarctation in infants and children.

Authors:  P S Rao; O Galal; P A Smith; A D Wilson
Journal:  J Am Coll Cardiol       Date:  1996-02       Impact factor: 24.094

9.  Balloon-expandable intracoronary stents in the adult dog.

Authors:  R A Schatz; J C Palmaz; F O Tio; F Garcia; O Garcia; S R Reuter
Journal:  Circulation       Date:  1987-08       Impact factor: 29.690

10.  Balloon dilatation of excised aortic coarctations.

Authors:  J E Lock; W R Castaneda-Zuniga; J L Bass; J E Foker; K Amplatz; R W Anderson
Journal:  Radiology       Date:  1982-06       Impact factor: 11.105

View more
  25 in total

1.  Three new applications of stent technology in a single patient.

Authors:  C J McMahon; H G El-Said; C E Mullins
Journal:  Tex Heart Inst J       Date:  2001

2.  A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits.

Authors:  M Peuster; P Wohlsein; M Brügmann; M Ehlerding; K Seidler; C Fink; H Brauer; A Fischer; G Hausdorf
Journal:  Heart       Date:  2001-11       Impact factor: 5.994

3.  Endovascular stenting for aortic (re)coarctation in adults.

Authors:  E Moltzer; J W Roos-Hesselink; S C Yap; J A A E Cuypers; A J J C Bogers; P P T de Jaegere; M Witsenburg
Journal:  Neth Heart J       Date:  2010-09       Impact factor: 2.380

4.  Middle Aortic Syndrome: Imaging and Endovascular Treatment.

Authors:  Menfil A Orellana-Barrios; Alvaro Rosales; Ayman Karkoutly; Gary E Meyerrose
Journal:  Tex Heart Inst J       Date:  2015-12-01

5.  The adult patient with native coarctation of the aorta: balloon angioplasty or primary stenting?

Authors:  C Zabal; F Attie; M Rosas; A Buendía-Hernández; J A García-Montes
Journal:  Heart       Date:  2003-01       Impact factor: 5.994

6.  Endovascular stents in the management of coarctation of the aorta in the adolescent and adult: one year follow up.

Authors:  D A Harrison; P R McLaughlin; C Lazzam; M Connelly; L N Benson
Journal:  Heart       Date:  2001-05       Impact factor: 5.994

7.  Effect of endovascular stenting of aortic coarctation on biventricular function in adults.

Authors:  Yat-Yin Lam; Mehmet G Kaya; Wei Li; Vaikom S Mahadevan; Arif A Khan; Michael Y Henein; Michael Mullen
Journal:  Heart       Date:  2007-06-17       Impact factor: 5.994

8.  The efficacy and safety of stent redilatation in congenital heart disease.

Authors:  C Duke; E Rosenthal; S A Qureshi
Journal:  Heart       Date:  2003-08       Impact factor: 5.994

9.  The role of stents in the treatment of congenital heart disease: Current status and future perspectives.

Authors:  Bjoern Peters; Peter Ewert; Felix Berger
Journal:  Ann Pediatr Cardiol       Date:  2009-01

10.  Use of covered stents to treat coarctation of the aorta.

Authors:  Shakeel Ahmed Qureshi
Journal:  Korean Circ J       Date:  2009-07-28       Impact factor: 3.243

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.