Literature DB >> 12860870

The efficacy and safety of stent redilatation in congenital heart disease.

C Duke1, E Rosenthal, S A Qureshi.   

Abstract

OBJECTIVES: To assess the extent of neointimal proliferation and the safety and efficacy of stent redilatation in patients with stents implanted for aortic coarctation or branch pulmonary artery stenosis.
DESIGN: Retrospective observational study.
SETTING: Tertiary referral centre. PATIENTS AND
INTERVENTIONS: Of 60 patients with Palmaz stents, 12 with coarctation and 12 with branch pulmonary artery stenosis (with 21 stented sites) underwent recatheterisation and stent redilatation.
RESULTS: Neointimal thickening > 1 mm was detected in six of the 12 coarctation stents and at nine of the 21 stented sites in branch pulmonary arteries (five of which had been overdilated at implantation). Eight of the coarctation stents were electively underdilated at implantation. Coarctation stent redilatation increased median (range) lumen diameter from 9.2 (6.3-11.1) mm to 11.7 (9.8-14.1) mm (p = 0.002), decreased gradient from 10.5 (0-20) mm Hg to 0.5 (0-15) mm Hg (p = 0.008), and increased the ratio of stent diameter to descending aorta diameter from 0.66 (0.38-1.02) to 0.85 (0.52-1.2) (p = 0.008). Pulmonary artery stent redilatation increased lumen diameter from 6.9 (3.8-13.5) mm to 8.8 (4.8-14.1) mm (p < 0.001), decreased gradient from 24 (2-62) mm Hg to 12 (0-29) mm Hg (p < 0.001), and increased the ratio of stent diameter to diameter of distal pulmonary artery from 0.66 (0.44-1.5) to 0.86 (0.48-1.88) (p = 0.001). Dilatation of one peripheral pulmonary artery stent resulted in rupture of the vessel distal to the stent.
CONCLUSIONS: Neointimal proliferation is precipitated by overdilating stents at implantation. Redilatation using balloons matched to distal vessel diameter increases stent lumen size, but may not optimise vessel diameter. Redilatation is effective whether the indication for redilatation is a resistant stenosis at implantation, underexpansion at implantation, neointimal proliferation, or relative stenosis caused by growth.

Entities:  

Mesh:

Year:  2003        PMID: 12860870      PMCID: PMC1767765          DOI: 10.1136/heart.89.8.905

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  22 in total

1.  Long-term follow-up of stents implanted to relieve peripheral pulmonary arterial stenosis: hemodynamic findings and results of lung perfusion scanning.

Authors:  I Spadoni; S Giusti; P Bertolaccini; A Maneschi; G Kraft; M Carminati
Journal:  Cardiol Young       Date:  1999-11       Impact factor: 1.093

2.  Early results and medium-term follow-up of stent implantation for mild residual or recurrent aortic coarctation.

Authors:  A C Marshall; S B Perry; J F Keane; J E Lock
Journal:  Am Heart J       Date:  2000-06       Impact factor: 4.749

3.  Implantation of balloon-expandable stents for coarctation of the aorta: implantation data and short-term results.

Authors:  Z R Bulbul; E Bruckheimer; J C Love; J T Fahey; W E Hellenbrand
Journal:  Cathet Cardiovasc Diagn       Date:  1996-09

4.  Endovascular stents for coarctation of the aorta: initial results and intermediate-term follow-up.

Authors:  M A Hamdan; S Maheshwari; J T Fahey; W E Hellenbrand
Journal:  J Am Coll Cardiol       Date:  2001-11-01       Impact factor: 24.094

5.  Redilation of endovascular stents in congenital heart disease: factors implicated in the development of restenosis and neointimal proliferation.

Authors:  C J McMahon; H G El-Said; R G Grifka; J K Fraley; M R Nihill; C E Mullins
Journal:  J Am Coll Cardiol       Date:  2001-08       Impact factor: 24.094

6.  Stent implantation for aortic coarctation and recoarctation.

Authors:  A G Magee; G Brzezinska-Rajszys; S A Qureshi; E Rosenthal; M Zubrzycka; J Ksiazyk; M Tynan
Journal:  Heart       Date:  1999-11       Impact factor: 5.994

7.  Immediate and follow-up findings after stent treatment for severe coarctation of aorta.

Authors:  J Suárez de Lezo; M Pan; M Romero; A Medina; J Segura; M Lafuente; D Pavlovic; E Hernández; F Melián; J Espada
Journal:  Am J Cardiol       Date:  1999-02-01       Impact factor: 2.778

8.  Intravascular stents in congenital heart disease: short- and long-term results from a large single-center experience.

Authors:  K M Shaffer; C E Mullins; R G Grifka; M P O'Laughlin; W McMahon; F F Ing; M R Nihill
Journal:  J Am Coll Cardiol       Date:  1998-03-01       Impact factor: 24.094

9.  Stent treatment for coarctation of the aorta: intermediate term follow up and technical considerations.

Authors:  B D Thanopoulos; L Hadjinikolaou; G N Konstadopoulou; G S Tsaousis; F Triposkiadis; P Spirou
Journal:  Heart       Date:  2000-07       Impact factor: 5.994

10.  Stent redilation in canine models of congenital heart disease: pulmonary artery stenosis and coarctation of the aorta.

Authors:  A M Mendelsohn; P C Dorostkar; C P Moorehead; F M Lupinetti; P I Reynolds; A Ludomirsky; T R Lloyd; K Heidelberger; R H Beekman
Journal:  Cathet Cardiovasc Diagn       Date:  1996-08
View more
  22 in total

1.  Bronchial compression following pulmonary artery stenting in single ventricle lesions: how to prevent, and how to decompress.

Authors:  J Grohmann; B Stiller; E Neumann; A Jakob; T Fleck; G Pache; M Siepe; R Höhn
Journal:  Clin Res Cardiol       Date:  2015-09-28       Impact factor: 5.460

2.  Transient sirolimus serum levels after implantation of a sirolimus eluting stent in an infant.

Authors:  Frank-Thomas Riede; Peter Schneider; Ingo Dähnert
Journal:  Clin Res Cardiol       Date:  2007-04-26       Impact factor: 5.460

3.  Stent-graft deployment for aortic rupture after stenting for aortic recoarctation.

Authors:  Juan Alcibar; Natividad Peña; Ramón Inguanzo; M Jesús Arriola; Koldobika Garcia; Ibon Eguia; Iñigo Sainz; José I Barrenetxea
Journal:  Tex Heart Inst J       Date:  2007

4.  Ultra-high-pressure balloon angioplasty for treatment of resistant stenoses within or adjacent to previously implanted pulmonary arterial stents.

Authors:  Jessica Maglione; Lisa Bergersen; James E Lock; Doff B McElhinney
Journal:  Circ Cardiovasc Interv       Date:  2008-12-15       Impact factor: 6.546

5.  Characterization and in vivo evaluation of a bio-corrodible nitrided iron stent.

Authors:  Qimao Feng; Deyuan Zhang; Chaohua Xin; Xiangdong Liu; Wenjiao Lin; Wanqian Zhang; Sun Chen; Kun Sun
Journal:  J Mater Sci Mater Med       Date:  2012-11-27       Impact factor: 3.896

6.  Coarctation of the aorta: management, indications for intervention, and advances in care.

Authors:  Mohammed Haris Umer Usman; Pablo Rengifo-Moreno; Sean F Janzer; Ignacio Inglessis-Azuaje; Christian Witzke-Sanz
Journal:  Curr Treat Options Cardiovasc Med       Date:  2014-10

Review 7.  Coarctation of the aorta.

Authors:  P Syamasundar Rao
Journal:  Curr Cardiol Rep       Date:  2005-11       Impact factor: 2.931

8.  Medium and long-term outcomes after bilateral pulmonary artery stenting in children and adults with congenital heart disease.

Authors:  Ismael Gonzalez; Damien Kenny; Shari Slyder; Ziyad M Hijazi
Journal:  Pediatr Cardiol       Date:  2012-07-28       Impact factor: 1.655

9.  Catheterisation laboratory is the place for rehabilitating the pulmonary arteries.

Authors:  Bhava Rj Kannan; Shakeel A Qureshi
Journal:  Ann Pediatr Cardiol       Date:  2008-07

10.  The role of stents in the treatment of congenital heart disease: Current status and future perspectives.

Authors:  Bjoern Peters; Peter Ewert; Felix Berger
Journal:  Ann Pediatr Cardiol       Date:  2009-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.