Literature DB >> 9266788

Intravascular ultrasound assessment of regional aortic wall stiffness, distensibility, and compliance in patients with coarctation of the aorta.

J Xu1, T Shiota, R Omoto, X Zhou, S Kyo, M Ishii, M J Rice, D J Sahn.   

Abstract

BACKGROUND: Impaired aortic pulsatility has been demonstrated by angiography in children and in studies of experimental animals with coarctation of the aorta.
OBJECTIVES: The purpose of this study was to assess regional aortic stiffness, distensibility, and compliance before and after balloon dilation in patients with coarctation of the aorta. METHODS AND
RESULTS: Intravascular ultrasound examination was performed in 13 pediatric patients with the diagnosis of coarctation of the aorta to yield aortic diameter. Area transverse sections at both systolic and diastolic period were measured at three aortic levels: the proximal, distal, and coarctation segments. Balloon dilation was also performed in eight of 13 patients. By using pressures measured in the same areas, an aortic stiffness index (beta) was calculated as In(Ps/Pd)/(Ds-Dd), where In is natural logarithm, Ps is systolic pressure, Pd is diastolic pressure, Ds is systolic diameter, and Dd is diastolic diameter. Aortic distensibility and an estimation of aortic compliance were also calculated. The beta stiffness index of the coarctation and the proximal segments of the aorta were significantly greater than that of the distal segment of the aorta (p < 0.01). The aortic wall stiffness beta index did not acutely change after successful balloon dilation, but the distensibility and compliance of distal aorta were nonetheless significantly decreased after balloon dilation (p < 0.01, p < 0.05) as a function of changes of pulsatility of flow.
CONCLUSIONS: Abnormal proximal aortic stiffness may be a strong contributing factor that promotes the genesis of hypertension in patients with coarctation even after successful repair or balloon angioplasty.

Entities:  

Mesh:

Year:  1997        PMID: 9266788     DOI: 10.1016/s0002-8703(97)70111-x

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  19 in total

1.  Low Peak dP/dt in the Descending Aorta in Patients After Successful Aortic Arch Repair.

Authors:  Masahiro Shiraishi; Tomoaki Murakami; Atsuhito Takeda
Journal:  Pediatr Cardiol       Date:  2017-11-27       Impact factor: 1.655

2.  Serum concentration of procollagen type III amino-terminal peptide is increased in patients with successfully repaired coarctation of the aorta with left ventricular hypertrophy.

Authors:  Hirokuni Yamazawa; Tomoaki Murakami; Atsuhito Takeda; Kouta Takei; Takuo Furukawa; Hiromichi Nakajima
Journal:  Pediatr Cardiol       Date:  2014-10-14       Impact factor: 1.655

3.  Intravascular Ultrasound Characterization of a Tissue-Engineered Vascular Graft in an Ovine Model.

Authors:  Victoria K Pepper; Elizabeth S Clark; Cameron A Best; Ekene A Onwuka; Tadahisa Sugiura; Eric D Heuer; Lilamarie E Moko; Shinka Miyamoto; Hideki Miyachi; Darren P Berman; Sharon L Cheatham; Joanne L Chisolm; Toshiharu Shinoka; Christopher K Breuer; John P Cheatham
Journal:  J Cardiovasc Transl Res       Date:  2017-01-17       Impact factor: 4.132

4.  Stent implantation for aortic coarctation and recoarctation.

Authors:  A G Magee; G Brzezinska-Rajszys; S A Qureshi; E Rosenthal; M Zubrzycka; J Ksiazyk; M Tynan
Journal:  Heart       Date:  1999-11       Impact factor: 5.994

5.  Quantification of aortic stiffness using magnetic resonance elastography: Measurement reproducibility, pulse wave velocity comparison, changes over cardiac cycle, and relationship with age.

Authors:  William E Kenyhercz; Brian Raterman; Venkata Sita Priyanka Illapani; Joshua Dowell; Xiaokui Mo; Richard D White; Arunark Kolipaka
Journal:  Magn Reson Med       Date:  2015-06-12       Impact factor: 4.668

6.  In-vivo assessment of the morphology and hemodynamic functions of the BioValsalva™ composite valve-conduit graft using cardiac magnetic resonance imaging and computational modelling technology.

Authors:  Emaddin Kidher; Zhuo Cheng; Omar A Jarral; Declan P O'Regan; Xiao Yun Xu; Thanos Athanasiou
Journal:  J Cardiothorac Surg       Date:  2014-12-09       Impact factor: 1.637

7.  The role of aortic compliance in determination of coarctation severity: Lumped parameter modeling, in vitro study and clinical evaluation.

Authors:  Zahra Keshavarz-Motamed; Elazer R Edelman; Payam K Motamed; Julio Garcia; Nagib Dahdah; Lyes Kadem
Journal:  J Biomech       Date:  2015-10-26       Impact factor: 2.712

8.  Impaired poststenotic aortic pulsatility after hemodynamically ideal coarctation repair in children.

Authors:  J-P Pfammatter; P Berdat; T Carrel
Journal:  Pediatr Cardiol       Date:  2004-05-12       Impact factor: 1.655

9.  Elimination of Transcoarctation Pressure Gradients Has No Impact on Left Ventricular Function or Aortic Shear Stress After Intervention in Patients With Mild Coarctation.

Authors:  Zahra Keshavarz-Motamed; Farhad Rikhtegar Nezami; Ramon A Partida; Kenta Nakamura; Pedro Vinícius Staziaki; Eyal Ben-Assa; Brian Ghoshhajra; Ami B Bhatt; Elazer R Edelman
Journal:  JACC Cardiovasc Interv       Date:  2016-09-26       Impact factor: 11.195

10.  Impaired cardiac and vascular motion in patients with Takayasu's arteritis: A velocity vector imaging-based study.

Authors:  Selen Yurdakul; Fatma Alibaz-Öner; Haner Direskeneli; Saide Aytekin
Journal:  Eur J Rheumatol       Date:  2017-10-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.