Literature DB >> 8853159

Stent redilation in canine models of congenital heart disease: pulmonary artery stenosis and coarctation of the aorta.

A M Mendelsohn1, P C Dorostkar, C P Moorehead, F M Lupinetti, P I Reynolds, A Ludomirsky, T R Lloyd, K Heidelberger, R H Beekman.   

Abstract

In a canine puppy model, pulmonary artery stenosis was created by banding the left pulmonary artery to 30-40% of its original diameter. Animals underwent right heart catheterization and angiography 1-2 mo later, and Palmaz P308 stents were implanted. Stent redilation was performed 3-5 mo later. One mo postredilation, the animals were restudied and sacrificed. Coarctations of the aorta were created by transverse aortic incision and longitudinal repair. P308 stent implantation was performed 2-3 mo later. Stent redilation was performed after 6-10 mo, and the animals were restudied and sacrificed 1-2 mo later. Stent implantation was performed in 6 puppies with pulmonary artery stenosis, as 2 animals developed postoperative pulmonary arterial hypoplasia, precluding stenting. The stenosis diameter increased from 4.8 +/- 0.5 mm to 7.4 +/- 0.6 mm (mean +/- SE) following stenting (P = 0.005), and increased further to 9.2 +/- 0.7 mm following redilation (P < 0.001). There were no significant vessel tears or ruptures. Coarctation stenting was performed in 8 animals. The coarctation was dilated from 5.8 +/- 0.9 mm to 9.8 +/- 0.6 mm (P < 0.001), and to 13.5 +/- 0.5 mm at redilation (P = 0.002). Redilation could not be performed in 1 animal. Aortic rupture and death occurred in 2 of 7 animals at redilation. Stent implantation and redilation in experimental pulmonary artery stenosis appears safe and effective. Though stent implantation for coarctation of the aorta appears safe, there was a 28% aortic rupture rate at stent redilation in this model.

Entities:  

Mesh:

Year:  1996        PMID: 8853159     DOI: 10.1002/(SICI)1097-0304(199608)38:4<430::AID-CCD24>3.0.CO;2-H

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  4 in total

1.  Stent implantation for aortic coarctation and recoarctation.

Authors:  A G Magee; G Brzezinska-Rajszys; S A Qureshi; E Rosenthal; M Zubrzycka; J Ksiazyk; M Tynan
Journal:  Heart       Date:  1999-11       Impact factor: 5.994

2.  The efficacy and safety of stent redilatation in congenital heart disease.

Authors:  C Duke; E Rosenthal; S A Qureshi
Journal:  Heart       Date:  2003-08       Impact factor: 5.994

3.  Cost-effectiveness of coarctation repair strategies: endovascular stenting versus surgery.

Authors:  J C George; D Shim; J C Bucuvalas; E Immerman; P B Manning; J M Pearl; R H Beekman
Journal:  Pediatr Cardiol       Date:  2003-07-29       Impact factor: 1.655

4.  Balloon expandable stents for coarctation of the aorta: review of current status and technical considerations.

Authors:  Mr Ebeid
Journal:  Images Paediatr Cardiol       Date:  2003-04
  4 in total