Literature DB >> 10505503

Posterior lumbar interbody fusion with cages: an independent review of 71 cases.

S Agazzi1, A Reverdin, D May.   

Abstract

OBJECT: The authors conducted a retrospective study to provide an independent evaluation of posterior lumbar interbody fusion (PLIF) in which impacted carbon cages were used. Interbody cages have been developed to replace tricortical interbody grafts in anterior and PLIF procedures. Superior fusion rates and clinical outcomes have been claimed by the developers.
METHODS: In a retrospective study, the authors evaluated 71 consecutive patients in whom surgery was performed between 1995 and 1997. The median follow-up period was 28 months. Clinical outcome was assessed using the Prolo scale. Fusion results were interpreted by an independent radiologist. The fusion rate was 90%. Overall, 67% of the patients were satisfied with their outcome and would undergo the same operation again. Based on the results of the Prolo scale, however, in only 39% of the patients were excellent or good results achieved. Forty-six percent of the work-eligible patients resumed their working activity. Clinical outcome and return-to-work status were significantly associated with socioeconomic factors such as preoperative employment (p = 0.03), compensation issues (p = 0.001), and length of preoperative sick leave (p = 0.01). Radiographically demonstrated fusion was not statistically related to clinical outcome (p = 0.2).
CONCLUSIONS: This is one of the largest independent series in which PLIF with cages has been evaluated. The results show that the procedure is safe and effective with a 90% fusion rate and a 66% overall satisfaction rate, which compare favorably with those of traditional fixation techniques but fail to match the higher results claimed by the innovators of the cage techniques. The authors' experience confirms the reports of others that many patients continue to experience incapacitating back pain despite successful fusion and neurological recovery.

Entities:  

Mesh:

Year:  1999        PMID: 10505503     DOI: 10.3171/spi.1999.91.2.0186

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  34 in total

1.  The importance of the endplate for interbody cages in the lumbar spine.

Authors:  Anne Polikeit; Stephen J Ferguson; Lutz P Nolte; Tracy E Orr
Journal:  Eur Spine J       Date:  2003-05-29       Impact factor: 3.134

2.  Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: finite element analysis.

Authors:  Anne Polikeit; Stephen J Ferguson; Lutz P Nolte; Tracy E Orr
Journal:  Eur Spine J       Date:  2002-12-19       Impact factor: 3.134

Review 3.  [Interbody metal implants ("cages") for lumbar fusion].

Authors:  G Freiherr von Salis-Soglio; R Scholz; K Seller
Journal:  Orthopade       Date:  2005-10       Impact factor: 1.087

4.  Adjacent segment instability after treatment with a Graf ligament at minimum 8 years' followup.

Authors:  Yongsoo Choi; Kisoo Kim; Kwangyoung So
Journal:  Clin Orthop Relat Res       Date:  2009-05-19       Impact factor: 4.176

5.  The influence of cage positioning and cage type on cage migration and fusion rates in patients with monosegmental posterior lumbar interbody fusion and posterior fixation.

Authors:  Alexander Abbushi; Mario Cabraja; Ulrich-Wilhelm Thomale; Christian Woiciechowsky; Stefan Nikolaus Kroppenstedt
Journal:  Eur Spine J       Date:  2009-05-28       Impact factor: 3.134

6.  Lumbar interbody fusion: a parametric investigation of a novel cage design with and without posterior instrumentation.

Authors:  Fabio Galbusera; Hendrik Schmidt; Hans-Joachim Wilke
Journal:  Eur Spine J       Date:  2011-09-15       Impact factor: 3.134

7.  Evaluation of the 96/4 PLDLLA polymer resorbable lumbar interbody cage in a long term animal model.

Authors:  Jean Y Lazennec; Abdallah Madi; Marc A Rousseau; Bernard Roger; Gérard Saillant
Journal:  Eur Spine J       Date:  2006-05-31       Impact factor: 3.134

8.  Volumetric change in interbody bone graft after posterior lumbar interbody fusion (PLIF): a prospective study.

Authors:  Zenya Ito; Shiro Imagama; Tokumi Kanemura; Kotaro Satake; Kei Ando; Kazuyoshi Kobayashi; Ryuichi Shinjo; Hideki Yagi; Tetsuro Hida; Kenyu Ito; Yoshimoto Ishikawa; Mikito Tsushima; Akiyuki Matsumoto; Hany El Zahlawy; Hidetoshi Yamaguchi; Yukihiro Matsuyama; Naoki Ishiguro
Journal:  Eur Spine J       Date:  2014-06-19       Impact factor: 3.134

9.  Effect of employment status on length of hospital stay, 30-day readmission and patient reported outcomes after spine surgery.

Authors:  Owoicho Adogwa; Aladine A Elsamadicy; Jared Fialkoff; Ankit I Mehta; Raul A Vasquez; Joseph Cheng; Isaac O Karikari; Carlos A Bagley
Journal:  J Spine Surg       Date:  2017-03

10.  Percutaneous posterior-lateral lumbar interbody fusion for degenerative disc disease using a B-Twin expandable spinal spacer.

Authors:  Lizu Xiao; Donglin Xiong; Qiang Zhang; Jin Jian; Husan Zheng; Yuhui Luo; Juanli Dai; Deren Zhang
Journal:  Eur Spine J       Date:  2009-09-26       Impact factor: 3.134

View more