Literature DB >> 10483943

Stented segment length as an independent predictor of restenosis.

Y Kobayashi1, J De Gregorio, N Kobayashi, T Akiyama, B Reimers, L Finci, C Di Mario, A Colombo.   

Abstract

OBJECTIVES: We sought to evaluate the relation between stented segment length and restenosis.
BACKGROUND: Multiple or long coronary stents are now being implanted in long lesions or in tandem lesions. A longer stented segment might result in a higher probability of restenosis. However, there is little information available on the relation between stented segment length and restenosis.
METHODS: Between April 1995 and December 1996, 725 patients with 1,090 lesions underwent stenting. Lesions were divided into three groups according to the length of the stented segment: 1) group I (n = 565): stented segment length < or =20 mm; 2) group II (n = 278): stented segment length >20 but < or =35 mm; and 3) group III (n = 247): stented segment length >35 mm.
RESULTS: There was no significant difference in the incidence of subacute stent thrombosis among the three groups (0.4% in group I, 0.4% in group II, 1.2% in group III; p = NS). The minimal lumen diameter (MLD) after stenting was greater in group I than in group III (3.04 +/- 0.60 mm in group I, 3.01 +/- 0.54 mm in group II, 2.91 +/- 0.58 mm in group III; p < 0.05). At follow up, a smaller MLD was observed in group III as compared with group I and group II (2.04 +/- 0.93 mm in group I, 1.92 +/- 1.00 mm in group II, 1.47 +/- 0.97 mm in group III; p < 0.01). The restenosis rates were 23.9% in group I, 34.6% in group II and 47.2% in group III (p < 0.01). Using multivariate analysis, the longer stented segment, the angiographic reference vessel diameter and the percent diameter stenosis after stenting were independent predictors of restenosis.
CONCLUSIONS: The present study shows that a longer stented segment is an independent predictor of restenosis without an influence on the risk of subacute thrombosis.

Entities:  

Mesh:

Year:  1999        PMID: 10483943     DOI: 10.1016/s0735-1097(99)00303-4

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  34 in total

Review 1.  Stent thrombosis: historical perspectives and current trends.

Authors:  D E Cutlip
Journal:  J Thromb Thrombolysis       Date:  2000-08       Impact factor: 2.300

2.  Drug eluting stents: maximising benefit and minimising cost.

Authors:  J Gunn; A C Morton; C Wales; C M H Newman; D C Crossman; D C Cumberland
Journal:  Heart       Date:  2003-02       Impact factor: 5.994

3.  Cobalt-chromium stents in long lesions of large vessels: clinical and angiographic results.

Authors:  Iñigo Lozano; Carlos Cuellas; Pablo Avanzas; Armando Pérez de Prado; Concepción Suárez; Juan Rondan; Daehyun Lee; Jesus M de la Hera; Felipe Fernández; César Morís
Journal:  Tex Heart Inst J       Date:  2011

4.  [Patients with coronary artery stents: when and how should operations be carried out?].

Authors:  W Rottbauer; H A Katus
Journal:  Chirurg       Date:  2009-06       Impact factor: 0.955

5.  Calibration-free device sizing using an inverse geometry x-ray system.

Authors:  Michael T Tomkowiak; Michael A Speidel; Amish N Raval; Michael S Van Lysel
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

6.  Utility of myocardial fractional flow reserve for prediction of restenosis following sirolimus-eluting stent implantation.

Authors:  Hideshi Ishii; Toru Kataoka; Yoshiki Kobayashi; Takara Tsumori; Hiroaki Takeshita; Ryo Matsumoto; Nobuyuki Shirai; Hiroki Nishioka; Takao Hasegawa; Shinji Nakata; Yoshihisa Shimada; Shoichi Ehara; Takashi Muro; Minoru Yoshiyama
Journal:  Heart Vessels       Date:  2011-01-08       Impact factor: 2.037

7.  Impact of bifurcation dual stenting on endothelial shear stress.

Authors:  Henry Y Chen; Bon-Kwon Koo; Ghassan S Kassab
Journal:  J Appl Physiol (1985)       Date:  2015-07-16

8.  Nine-Months Clinical Outcome of Biodegradable Polymer Coated Sirolimus-eluting Stent System: A Multi-Centre "Real-World" Experience.

Authors:  Raghava Sarma; Jayesh Prajapati; Asif Raheem; Kamlesh Thakkar; Shivani Kothari; Ashok Thakkar
Journal:  J Clin Diagn Res       Date:  2015-08-01

Review 9.  Restenosis after PCI. Part 1: pathophysiology and risk factors.

Authors:  J Wouter Jukema; Jeffrey J W Verschuren; Tarek A N Ahmed; Paul H A Quax
Journal:  Nat Rev Cardiol       Date:  2011-09-13       Impact factor: 32.419

10.  Calibration-Free Coronary Artery Measurements for Interventional Device Sizing using Inverse Geometry X-ray Fluoroscopy: In Vivo Validation.

Authors:  Michael T Tomkowiak; Amish N Raval; Michael S Van Lysel; Tobias Funk; Michael A Speidel
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.