Impact of bifurcation dual stenting on endothelial shear stress.

Henry Y Chen1, Bon-Kwon Koo2, Ghassan S Kassab3.   

Abstract

Despite advances in percutaneous coronary interventions and the introduction of drug eluding stents, in-stent restenosis and stent thrombosis remain a clinically significant problem for bifurcations. The aim of this study is to determine the effect of dual bifurcation stenting on hemodynamic parameters known to influence restenosis and thrombosis. We hypothesized that double stenting, especially with a longer side branch (SB) stent, likely has a negative effect on wall shear stress (WSS), WSS gradient (WSSG), and oscillatory shear index (OSI). To test this hypothesis, we developed computational models of dual stents at bifurcations and non-Newtonian blood simulations. The models were then interfaced, meshed, and solved in a validated finite-element package. Longer and shorter stents at the SB and provisional stenting were compared. It was found that stents placed in the SB at a bifurcation lowered WSS, but elevated WSSG and OSI. Dual stenting with longer SB stent had the most adverse impact on SB endothelial WSS, WSSG, and OSI, with low WSS region up to 50% more than the case with shorter SB stent. The simulations also demonstrated flow disturbances resulting from SB stent struts protruding into the main flow field near the carina, which may have implications on stent thrombosis. The simulations predict a negative hemodynamic role for SB stenting, which is exaggerated with a longer stent, consistent with clinical trial findings that dual-stenting is comparable or inferior to provisional stenting.
Copyright © 2015 the American Physiological Society.

Entities:  

Keywords:  adverse events; bifurcation dual stenting; endothelial shear stress; provisional stenting; target-vessel revascularization

Mesh:

Year:  2015        PMID: 26183473      PMCID: PMC4687863          DOI: 10.1152/japplphysiol.00082.2015

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  30 in total

1.  Numerical analysis of flow through a severely stenotic carotid artery bifurcation.

Authors:  J S Stroud; S A Berger; D Saloner
Journal:  J Biomech Eng       Date:  2002-02       Impact factor: 2.097

2.  Intravascular ultrasound-guided percutaneous transluminal coronary angioplasty with provisional spot stenting for treatment of long coronary lesions.

Authors:  A Colombo; J De Gregorio; I Moussa; Y Kobayashi; E Karvouni; C Di Mario; R Albiero; L Finci; J Moses
Journal:  J Am Coll Cardiol       Date:  2001-11-01       Impact factor: 24.094

3.  Nitric oxide is significantly reduced in ex vivo porcine arteries during reverse flow because of increased superoxide production.

Authors:  X Lu; G S Kassab
Journal:  J Physiol       Date:  2004-10-07       Impact factor: 5.182

Review 4.  Shear stress biology of the endothelium.

Authors:  Peter F Davies; Jos A Spaan; Robert Krams
Journal:  Ann Biomed Eng       Date:  2005-12       Impact factor: 3.934

5.  Effects of stent sizing on endothelial and vessel wall stress: potential mechanisms for in-stent restenosis.

Authors:  Henry Y Chen; James Hermiller; Anjan K Sinha; Michael Sturek; Luoding Zhu; Ghassan S Kassab
Journal:  J Appl Physiol (1985)       Date:  2009-03-19

6.  Mis-sizing of stent promotes intimal hyperplasia: impact of endothelial shear and intramural stress.

Authors:  Henry Y Chen; Anjan K Sinha; Jenny S Choy; Hai Zheng; Michael Sturek; Brian Bigelow; Deepak L Bhatt; Ghassan S Kassab
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-09-16       Impact factor: 4.733

7.  Impact of main branch stenting on endothelial shear stress: role of side branch diameter, angle and lesion.

Authors:  Henry Y Chen; Issam D Moussa; Charles Davidson; Ghassan S Kassab
Journal:  J R Soc Interface       Date:  2011-11-23       Impact factor: 4.118

8.  Effects of hematocrit and plasma proteins on human blood rheology at low shear rates.

Authors:  S Chien; S Usami; H M Taylor; J L Lundberg; M I Gregersen
Journal:  J Appl Physiol       Date:  1966-01       Impact factor: 3.531

9.  Relationship between neointimal thickness and shear stress after Wallstent implantation in human coronary arteries.

Authors:  J J Wentzel; R Krams; J C Schuurbiers; J A Oomen; J Kloet; W J van Der Giessen; P W Serruys; C J Slager
Journal:  Circulation       Date:  2001-04-03       Impact factor: 29.690

10.  Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis.

Authors:  Stéphane Cook; Elena Ladich; Gaku Nakazawa; Parham Eshtehardi; Michel Neidhart; Rolf Vogel; Mario Togni; Peter Wenaweser; Michael Billinger; Christian Seiler; Steffen Gay; Bernhard Meier; Werner J Pichler; Peter Jüni; Renu Virmani; Stephan Windecker
Journal:  Circulation       Date:  2009-07-20       Impact factor: 29.690

View more
  4 in total

1.  The impact of IVUS guidance in treating complex lesions; are all "complex" lesions the same?

Authors:  Kayode O Kuku; Alexandre H Kajita; Hector M Garcia-Garcia
Journal:  Cardiovasc Diagn Ther       Date:  2017-12

Review 2.  Microstructure-based biomechanics of coronary arteries in health and disease.

Authors:  Huan Chen; Ghassan S Kassab
Journal:  J Biomech       Date:  2016-03-20       Impact factor: 2.712

3.  Intermediate analysis of magnesium alloy covered stent for a lateral aneurysm model in the rabbit common carotid artery.

Authors:  Hong-Kai Cui; Fen-Bao Li; Ying-Chang Guo; Yong-Li Zhao; Rui-Fang Yan; Wu Wang; Yong-Dong Li; Yong-Li Wang; Guang-Yin Yuan
Journal:  Eur Radiol       Date:  2017-01-26       Impact factor: 5.315

4.  Biomechanical impact of provisional stenting and balloon dilatation on coronary bifurcation: clinical implications.

Authors:  Henry Y Chen; Khalid Al-Saadon; Yves Louvard; Ghassan S Kassab
Journal:  J Appl Physiol (1985)       Date:  2017-04-27
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.