Literature DB >> 10472522

Dynamic obstruction, an unusual complication after aortic valve replacement with a stentless porcine valve.

R P van Roosmalen1, L H Baur, J Braun, D E Atsma, M G Hazekamp, E E van der Wall, H A Huysmans.   

Abstract

In the early nineties, the stentless porcine aortic bioprosthesis has been reintroduced successfully. Because of the limited experience, knowledge of clinical complications is limited. Therefore, we describe an unusual complication of dynamic obstruction after aortic valve replacement with a stentless porcine valve in a 70 year old man 18 months after implantation. We discuss the complications of stentless aortic prostheses known so far, describe operative techniques used and their characteristic two dimensional echocardiographic images.

Entities:  

Mesh:

Year:  1999        PMID: 10472522     DOI: 10.1023/a:1006189321277

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  25 in total

1.  In vitro evaluation of a stentless porcine aortic bioprosthesis. A preliminary study.

Authors:  H W Sung; C J Kingsbury; L J Quintero; K E Myers; T N Le; A P Yoganathan; R C Quijano
Journal:  ASAIO Trans       Date:  1991 Jul-Sep

2.  Hemodynamic benefits of the Toronto Stentless Valve.

Authors:  D F Del Rizzo; B S Goldman; G T Christakis; T E David
Journal:  J Thorac Cardiovasc Surg       Date:  1996-12       Impact factor: 5.209

3.  Technique for complete subcoronary implantation of the Medtronic Freestyle porcine bioprosthesis.

Authors:  A H Krause
Journal:  Ann Thorac Surg       Date:  1997-11       Impact factor: 4.330

4.  Aortic valve replacement with allograft/autograft: subcoronary versus intraluminal cylinder or root.

Authors:  J E Rubay; D Raphael; T Sluysmans; J L Vanoverschelde; A Robert; J C Schoevaerdts; B Marchandise; R A Dion
Journal:  Ann Thorac Surg       Date:  1995-08       Impact factor: 4.330

5.  The Toronto SPV bioprosthesis: one-year results in 100 patients.

Authors:  F W Mohr; T Walther; M Baryalei; V Falk; R Autschbach; A Scheidt; H Dalichau
Journal:  Ann Thorac Surg       Date:  1995-07       Impact factor: 4.330

6.  Calcification of porcine valves: a successful new method of antimineralization.

Authors:  J P Gott; L M Dorsey; J L Jay; G K Jett; F J Schoen; J M Girardot; R A Guyton
Journal:  Ann Thorac Surg       Date:  1992-02       Impact factor: 4.330

7.  The value of the stentless biovalve prosthesis. An experimental study.

Authors:  M G Hazekamp; Y A Goffin; H A Huysmans
Journal:  Eur J Cardiothorac Surg       Date:  1993       Impact factor: 4.191

8.  Aortic valve replacement with a stentless porcine aortic valve. A six-year experience.

Authors:  T E David; C M Feindel; J Bos; Z Sun; H E Scully; H Rakowski
Journal:  J Thorac Cardiovasc Surg       Date:  1994-12       Impact factor: 5.209

9.  Stentless porcine aortic root: valve of choice for the elderly patient with small aortic root?

Authors:  C F Sintek; A D Fletcher; S Khonsari
Journal:  J Thorac Cardiovasc Surg       Date:  1995-05       Impact factor: 5.209

10.  Death and other time-related events after valve replacement.

Authors:  E H Blackstone; J W Kirklin
Journal:  Circulation       Date:  1985-10       Impact factor: 29.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.