Literature DB >> 7983872

Aortic valve replacement with a stentless porcine aortic valve. A six-year experience.

T E David1, C M Feindel, J Bos, Z Sun, H E Scully, H Rakowski.   

Abstract

A stentless porcine aortic valve was used for aortic valve replacement in 123 patients from 1987 to 1993. The mean age of 86 men and 37 women was 61 +/- 12 years. Most patients had aortic stenosis; one-third had coronary artery disease and six had mitral valve disease. The stentless valve was secured in the subcoronary position by the same technique used for a freehand aortic valve homograft. The size of valve was based largely on the diameter of the sinotubular junction of the aortic root. The mean valve size was 26.5 mm (range 19 to 29 mm) and 87% were 25 mm or larger. Two operative deaths occurred, one the result of myocardial infarction and the other the result of infective endocarditis. Patients have been followed up from 3 to 77 months, mean 22 months. Three late deaths, none related to the valve, have occurred. The actuarial survival at 6 years was 91% +/- 4%. Four transient cerebral ischemic events have occurred, but two patients had extracranial cerebrovascular disease. One patient had endocarditis late in the postoperative period and required reoperation. All patients had Doppler echocardiographic studies before discharge from the hospital, 3 to 6 months later and annually. Only 15 patients have aortic insufficiency, trivial in 6 and mild in 9. The peak and mean systolic gradients decreased significantly during the first 3 to 6 months after implantation (p < 0.001), and the effective valve areas increased significantly during this time interval (p < 0.001). This improvement in valve hemodynamics is believed to be due to remodeling of the aortic root and regression of left ventricular hypertrophy. The results of aortic valve replacement with this stentless bioprosthesis have been excellent and justify its continued use in older patients.

Entities:  

Mesh:

Year:  1994        PMID: 7983872

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  6 in total

1.  One-dimensional experimental mechanical characterisation of porcine aortic root wall.

Authors:  C Ferraresi; A M Bertetto; L Mazza; D Maffiodo; W Franco
Journal:  Med Biol Eng Comput       Date:  1999-03       Impact factor: 2.602

2.  Dynamic obstruction, an unusual complication after aortic valve replacement with a stentless porcine valve.

Authors:  R P van Roosmalen; L H Baur; J Braun; D E Atsma; M G Hazekamp; E E van der Wall; H A Huysmans
Journal:  Int J Card Imaging       Date:  1999-06

3.  The use of a stentless porcine bioprosthesis to repair an ascending aortic aneurysm in combination with aortic valve regurgitation.

Authors:  B Akpinar; I Sanisoğlu; C Konuralp; H Akay; M Güden; B Sönmez
Journal:  Tex Heart Inst J       Date:  1999

4.  Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography.

Authors:  Giovanni Minardi; Carla Manzara; Vittorio Creazzo; Daniele Maselli; Giovanni Casali; Giovanni Pulignano; Francesco Musumeci
Journal:  J Cardiothorac Surg       Date:  2006-09-19       Impact factor: 1.637

Review 5.  Prosthesis-patient mismatch - what cardiac anesthesiologists need to know?

Authors:  Kathirvel Subramaniam; Soheyla Nazarnia
Journal:  Ann Card Anaesth       Date:  2017 Apr-Jun

6.  Aortic valve replacement in elderly with small aortic root and low body surface area; the Perceval S valve and its impact in effective orifice area.

Authors:  Panagiotis Dedeilias; Nikolaos G Baikoussis; Efstathia Prappa; Dimitrios Asvestas; Michalis Argiriou; Christos Charitos
Journal:  J Cardiothorac Surg       Date:  2016-04-11       Impact factor: 1.637

  6 in total