Evaluation of a real-time blood glucose monitor in children with diabetic ketoacidosis.

J A Coss-Bu1, L S Jefferson, S Stone-McCord, C N Ou, C Watrin, R Sachdeva, K C Copeland.   

Abstract

Use of a real-time bedside glucose monitor was analyzed during the course of management of diabetic ketoacidosis (DKA) in children. Simultaneous determinations of blood glucose were obtained, using three methods: bedside glucose meter (One Touch II), laboratory glucose analyzer (YSI 2300 STAT), and a real-time bedside glucose monitor (VIA 1-01G Blood Chemistry monitor). Study patients included seventeen patients < 18 years of age admitted to a Pediatric Intensive Care Unit, with blood samples obtained during treatment of DKA by continuous insulin infusion. Four patients did not complete the study. Three experienced temporary technical problems with the monitor, and four required repeat IV placement. Duration of monitor use ranged between 6 and 47 h (mean 24 +/- 4 h). Blood glucose values ranged between 2.6 and 22.5 mmol/l. Overall correlation of blood glucose values were as follows: 0.965, 0.965, 0.973, VIA 1-01G vs. One Touch II, VIA 1-01G vs. YSI 2300 STAT, and One Touch II vs. YSI 2300 STAT, respectively (all P-values < 0.0001). This real-time bedside glucose monitor is accurate at glucose values < 13.8 mmol/l, and reliable for rapid, repetitive analyses. Results indicate that blood glucose values obtained using this real-time monitor are comparable to those using standard methods of measurement, and that this device is clinically applicable for use in management of children with DKA.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10462140     DOI: 10.1016/s0168-8227(99)00033-9

Source DB:  PubMed          Journal:  Diabetes Res Clin Pract        ISSN: 0168-8227            Impact factor:   5.602


  6 in total

1.  Evaluation of point-of-care blood glucose measurements in patients with diabetic ketoacidosis or hyperglycemic hyperosmolar syndrome admitted to a critical care unit.

Authors:  Dawn E Corl; Tom S Yin; Michelle E Mills; Tina L Spencer; Lucy Greenfield; Erin Beauchemin; Jessica Cochran; Louise D Suhr; Rachel E Thompson; Brent E Wisse
Journal:  J Diabetes Sci Technol       Date:  2013-09-01

2.  Clinical Use of Continuous Glucose Monitoring in Pediatrics.

Authors:  Rayhan A Lal; David M Maahs
Journal:  Diabetes Technol Ther       Date:  2017-05       Impact factor: 6.118

Review 3.  Vascular Glucose Sensor Symposium: Continuous Glucose Monitoring Systems (CGMS) for Hospitalized and Ambulatory Patients at Risk for Hyperglycemia, Hypoglycemia, and Glycemic Variability.

Authors:  Jeffrey I Joseph; Marc C Torjman; Paul J Strasma
Journal:  J Diabetes Sci Technol       Date:  2015-06-15

4.  Estimating plasma glucose with the FreeStyle Libre Pro continuous glucose monitor during oral glucose tolerance tests in youth without diabetes.

Authors:  Nejla Ghane; Miranda M Broadney; Elisabeth K Davis; Robert W Trenschel; Shavonne M Collins; Sheila M Brady; Jack A Yanovski
Journal:  Pediatr Diabetes       Date:  2019-08-29       Impact factor: 4.866

5.  Glucose monitoring in acute care: technologies on the horizon.

Authors:  Marc C Torjman; Niti Dalal; Michael E Goldberg
Journal:  J Diabetes Sci Technol       Date:  2008-03

6.  Evaluation of the VIA Blood Chemistry Monitor for Glucose in Healthy and Diabetic Volunteers.

Authors:  Arjunan Ganesh; Brian Hipszer; Navdeep Loomba; Barbara Simon; Marc C Torjman; Jeffrey Joseph
Journal:  J Diabetes Sci Technol       Date:  2008-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.