Literature DB >> 10460132

An improved method for measuring tibiofemoral contact areas in total knee arthroplasty: a comparison of K-scan sensor and Fuji film.

M L Harris1, P Morberg, W J Bruce, W R Walsh.   

Abstract

A computerised, real time, thin-film pressure transducer method is used to measure tibiofemoral contact area in total knee arthroplasty (TKA) devices that is easier and more reliable and reproducible as compared to the Fuji pressure-sensitive film technique. Many authors have suggested that contact areas and pressures within TKA devices can be a predictor of wear and failure of the ultra-high molecular weight polyethylene (UHMWPE) tibial insert. In this study, two contact area measurement techniques (Fuji pressure-sensitive Film and K-scan sensor system) were compared using a custom TKA testing jig designed for freedom of movement so that in any loading configuration the component found and seated in its own "home" position. The K-scan system was used to measure contact areas of one TKA design at several angles from 0 to 110 degrees flexion with loads equating to 4, 4.5, and 5 times body weight. For comparison, four ranges of Fuji film were used to measure areas at the same flexion angles but at 5 times body weight only. Contact areas measured with the Fuji films were 11-36% (p < 0.05) lower than those measured by the K-scan sensor.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10460132     DOI: 10.1016/s0021-9290(99)00072-x

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  24 in total

1.  MRI-based modeling for radiocarpal joint mechanics: validation criteria and results for four specimen-specific models.

Authors:  Kenneth J Fischer; Joshua E Johnson; Alexander J Waller; Terence E McIff; E Bruce Toby; Mehmet Bilgen
Journal:  J Biomech Eng       Date:  2011-10       Impact factor: 2.097

2.  Measuring the pressure pattern of the joint surface in the uninjured knee.

Authors:  Richard K Kdolsky; Basil Al Arabid; Martin Fuchs; Rudolf Schabus; Vilmos Vécsei
Journal:  Wien Klin Wochenschr       Date:  2004-03-31       Impact factor: 1.704

3.  Sensate scaffolds can reliably detect joint loading.

Authors:  C L Bliss; J A Szivek; B C Tellis; D S Margolis; A B Schnepp; J T Ruth
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2007-04       Impact factor: 3.368

4.  The influence of pre-tensioning of meniscal transplants on the tibiofemoral contact area.

Authors:  G von Lewinski; C Hurschler; C Allmann; C J Wirth
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-11-22       Impact factor: 4.342

5.  Effects of initial graft tension on the tibiofemoral compressive forces and joint position after anterior cruciate ligament reconstruction.

Authors:  Mark F Brady; Michael P Bradley; Braden C Fleming; Paul D Fadale; Michael J Hulstyn; Rahul Banerjee
Journal:  Am J Sports Med       Date:  2007-01-11       Impact factor: 6.202

6.  Dynamic measurement of patellofemoral kinematics and contact pressure after lateral retinacular release: an in vitro study.

Authors:  Sven Ostermeier; Marc Holst; Christof Hurschler; Henning Windhagen; Christina Stukenborg-Colsman
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-01-16       Impact factor: 4.342

7.  Tibiofemoral contact areas and pressures in six high flexion knees.

Authors:  Kei Shiramizu; Frank Vizesi; Warwick Bruce; Sebastian Herrmann; William R Walsh
Journal:  Int Orthop       Date:  2007-11-22       Impact factor: 3.075

8.  Intra-articular compressive stress of the elbow joint in extension: an experimental study using Fuji films.

Authors:  C Chantelot; G Wavreille; C Dos Remedios; B Landejerit; C Fontaine; H Hildebrand
Journal:  Surg Radiol Anat       Date:  2008-01-29       Impact factor: 1.246

9.  Posterior stabilized TKA reduce patellofemoral contact pressure compared with cruciate retaining TKA in vitro.

Authors:  Christoph Becher; Thomas J Heyse; Nadine Kron; Sven Ostermeier; Christof Hurschler; Markus D Schofer; Susanne Fuchs-Winkelmann; Carsten O Tibesku
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-03-21       Impact factor: 4.342

10.  Ia-FEMesh: anatomic FE models--a check of mesh accuracy and validity.

Authors:  Nicole A Devries; Kiran H Shivanna; Srinivas C Tadepalli; Vincent A Magnotta; Nicole M Grosland
Journal:  Iowa Orthop J       Date:  2009
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.