Literature DB >> 16941586

Sensate scaffolds can reliably detect joint loading.

C L Bliss1, J A Szivek, B C Tellis, D S Margolis, A B Schnepp, J T Ruth.   

Abstract

Treatment of cartilage defects is essential to the prevention of osteoarthritis. Scaffold-based cartilage tissue engineering shows promise as a viable technique to treat focal defects. Added functionality can be achieved by incorporating strain gauges into scaffolds, thereby providing a real-time diagnostic measurement of joint loading. Strain-gauged scaffolds were placed into the medial femoral condyles of 14 adult canine knees and benchtop tested. Loads between 75 and 130 N were applied to the stifle joints at 30 degrees, 50 degrees, and 70 degrees of flexion. Strain-gauged scaffolds were able to reliably assess joint loading at all applied flexion angles and loads. Pressure sensitive films were used to determine joint surface pressures during loading and to assess the effect of scaffold placement on joint pressures. A comparison of peak pressures in control knees and joints with implanted scaffolds, as well as a comparison of pressures before and after scaffold placement, showed that strain-gauged scaffold implantation did not significantly alter joint pressures. Future studies could possibly use strain-gauged scaffolds to clinically establish normal joint loads and to determine loads that are damaging to both healthy and tissue-engineered cartilage. Strain-gauged scaffolds may significantly aid the development of a functional engineered cartilage tissue substitute as well as provide insight into the native environment of cartilage. (c) 2006 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 16941586      PMCID: PMC2396224          DOI: 10.1002/jbm.b.30632

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  66 in total

Review 1.  From lab bench to market: critical issues in tissue engineering.

Authors:  Gail K Naughton
Journal:  Ann N Y Acad Sci       Date:  2002-06       Impact factor: 5.691

2.  Prediction of growth factor effects on engineered cartilage composition using deterministic and stochastic modeling.

Authors:  Asit K Saha; Jagannath Mazumdar; Sean S Kohles
Journal:  Ann Biomed Eng       Date:  2004-06       Impact factor: 3.934

Review 3.  Functional tissue engineering parameters toward designing repair and replacement strategies.

Authors:  David L Butler; Jason T Shearn; Natalia Juncosa; Matthew R Dressler; Shawn A Hunter
Journal:  Clin Orthop Relat Res       Date:  2004-10       Impact factor: 4.176

4.  Mechanical changes in the knee after meniscectomy.

Authors:  W R Krause; M H Pope; R J Johnson; D G Wilder
Journal:  J Bone Joint Surg Am       Date:  1976-07       Impact factor: 5.284

5.  The effect of medial meniscectomy and coronal plane angulation on in vitro load transmission in the canine stifle joint.

Authors:  A P Newman; D R Anderson; A U Daniels; K W Jee
Journal:  J Orthop Res       Date:  1989       Impact factor: 3.494

6.  Late degenerative changes after meniscectomy. Factors affecting the knee after operation.

Authors:  P R Allen; R A Denham; A V Swan
Journal:  J Bone Joint Surg Br       Date:  1984-11

7.  Missing osteoconductive effect of a resorbable PEO/PBT copolymer in human bone defects: a clinically relevant pilot study with contrary results to previous animal studies.

Authors:  M Roessler; A Wilke; P Griss; H Kienapfel
Journal:  J Biomed Mater Res       Date:  2000

8.  Effects of osteochondral defect size on cartilage contact stress.

Authors:  T D Brown; D F Pope; J E Hale; J A Buckwalter; R A Brand
Journal:  J Orthop Res       Date:  1991-07       Impact factor: 3.494

9.  In vivo mesenchymal cell recruitment by a scaffold loaded with transforming growth factor beta1 and the potential for in situ chondrogenesis.

Authors:  Q Huang; J C H Goh; D W Hutmacher; E H Lee
Journal:  Tissue Eng       Date:  2002-07

10.  Autologous osteochondral mosaicplasty. Surgical technique.

Authors:  László Hangody; Gábor K Ráthonyi; Zsófia Duska; Gábor Vásárhelyi; Péter Füles; László Módis
Journal:  J Bone Joint Surg Am       Date:  2004-03       Impact factor: 5.284

View more
  3 in total

1.  A novel biomimetic polymer scaffold design enhances bone ingrowth.

Authors:  Chris P Geffre; David S Margolis; John T Ruth; Donald W DeYoung; Brandi C Tellis; John A Szivek
Journal:  J Biomed Mater Res A       Date:  2009-12       Impact factor: 4.396

2.  Sensate scaffolds coupled to telemetry can monitor in vivo loading from within a joint over extended periods of time.

Authors:  Chris P Geffre; Cody L Bliss; John A Szivek; Donald W Deyoung; John T Ruth; David S Margolis
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2008-01       Impact factor: 3.368

Review 3.  Implantable sensor technology: measuring bone and joint biomechanics of daily life in vivo.

Authors:  Darryl D D'Lima; Benjamin J Fregly; Clifford W Colwell
Journal:  Arthritis Res Ther       Date:  2013-01-31       Impact factor: 5.156

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.