Literature DB >> 10458176

Follow-up of the original cohort with the Ahmed glaucoma valve implant.

F Topouzis1, A L Coleman, N Choplin, M M Bethlem, R Hill, F Yu, W C Panek, M R Wilson.   

Abstract

PURPOSE: To study the long-term results of the Ahmed glaucoma valve implant in patients with complicated glaucoma in whom short-term results have been reported.
METHODS: In this multicenter study, we analyzed the long-term outcome of a cohort of 60 eyes from 60 patients in whom the Ahmed glaucoma valve was implanted. Failure was characterized by at least one of the following: intraocular pressure greater than 21 mm Hg at both of the last two visits less than 6 mm Hg at both of the last two visits, loss of light perception, additional glaucoma surgery, devastating complications, and removal or replacement of the Ahmed glaucoma valve implant. Devastating complications included chronic hypotony, retinal detachment, malignant glaucoma, endophthalmitis, and phthisis bulbi; we also report results that add corneal complications (corneal decompensation or edema, corneal graft failure) as defining a devastating complication.
RESULTS: The mean follow-up time for the 60 eyes was 30.5 months (range, 2.1 to 63.5). When corneal complications were included in the definition of failure, 26 eyes (43%) were considered failures. Cumulative probabilities of success at 1, 2, 3, and 4 years were 76%, 68%, 54%, and 45%, respectively. When corneal complications were excluded from the definition of failure, 13 eyes (21.5%) were considered failures. Cumulative probabilities of success at 1, 2, 3, and 4 years were 87%, 82%, 76%, and 76%, respectively. Most of the failures after 12 months of postoperative follow-up were because of corneal complications.
CONCLUSIONS: The long-term performance of the Ahmed glaucoma valve implant is comparable to other drainage devices. More than 12 months after the implantation of the Ahmed glaucoma valve implant, the most frequent adverse outcome was corneal decompensation or corneal graft failure. These corneal problems may be secondary to the type of eyes that have drainage devices or to the drainage device itself. Further investigation is needed to identify the reasons that corneal problems follow drainage device implantation.

Entities:  

Mesh:

Year:  1999        PMID: 10458176     DOI: 10.1016/s0002-9394(99)00080-x

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  63 in total

1.  Building a safer trabeculectomy.

Authors:  S Lin
Journal:  Br J Ophthalmol       Date:  2006-01       Impact factor: 4.638

2.  Baerveldt glaucoma implant insertion in the posterior chamber sulcus.

Authors:  Celso Tello; Edgar M Espana; Ricardo Mora; Syril Dorairaj; Jeffrey M Liebmann; Robert Ritch
Journal:  Br J Ophthalmol       Date:  2007-02-14       Impact factor: 4.638

Review 3.  Aqueous shunts for glaucoma.

Authors:  D S Minckler; S S Vedula; T J Li; M C Mathew; R S Ayyala; B A Francis
Journal:  Cochrane Database Syst Rev       Date:  2006-04-19

4.  Surgical outcomes of patients with iridocorneal endothelial syndrome: a case series.

Authors:  Serhat Imamoglu; Mehmet S Sevim; Hatice Elvin Yıldız; Ece Turan Vural; Handan Bardak; Yavuz Bardak
Journal:  Int Ophthalmol       Date:  2016-08-06       Impact factor: 2.031

5.  Serial intracameral visualization of the Ahmed glaucoma valve tube by anterior segment optical coherence tomography.

Authors:  H-Y Lopilly Park; K I Jung; C K Park
Journal:  Eye (Lond)       Date:  2012-06-29       Impact factor: 3.775

6.  Dellen-like keratopathy associated with glaucoma drainage devices.

Authors:  Carlton Robert Fenzl; Majid Moshirfar; Adam John Gess; Valliammai Muthappan; Jason Goldsmith
Journal:  World J Clin Cases       Date:  2014-01-16       Impact factor: 1.337

7.  Ahmed glaucoma valve implant: experience in East Africa.

Authors:  D O Kiage; D Gradin; S Gichuhi; K F Damji
Journal:  Middle East Afr J Ophthalmol       Date:  2009-07

8.  Efficacy and safety of the pars plana clip in the Ahmed valve device inserted via the pars plana in patients with refractory glaucoma.

Authors:  Manuel Diaz-Llopis; David Salom; Salvador García-Delpech; Patricia Udaondo; Jose Maria Millan; J Fernando Arevalo
Journal:  Clin Ophthalmol       Date:  2010-05-06

9.  Evaluation of Ahmed glaucoma valve implantation through a needle-generated scleral tunnel in Mexican children with glaucoma.

Authors:  Oscar Albis-Donado; Félix Gil-Carrasco; Rafael Romero-Quijada; Ravi Thomas
Journal:  Indian J Ophthalmol       Date:  2010 Sep-Oct       Impact factor: 1.848

10.  The efficacy of Ahmed glaucoma valve drainage devices in cases of adult refractory glaucoma in Indian eyes.

Authors:  Jitendra K S Parihar; Devendra P Vats; Rakesh Maggon; Vijay Mathur; Anirudh Singh; Sanjay K Mishra
Journal:  Indian J Ophthalmol       Date:  2009 Sep-Oct       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.