| Literature DB >> 27495952 |
Serhat Imamoglu1, Mehmet S Sevim2, Hatice Elvin Yıldız2, Ece Turan Vural2, Handan Bardak2, Yavuz Bardak2.
Abstract
The purpose of this study is to report the intermediate-term surgical outcomes of patients with iridocorneal endothelial syndrome-related glaucoma. The medical records of four patients (five eyes) surgery (Ahmed glaucoma valve implantation surgery and EX-PRESS mini shunt) were retrospectively reviewed. Median follow-up after glaucoma surgery was 24 (15-36) months. The preoperative intraocular pressure was significantly reduced from a median of 33 (22.5-36) mmHg on a median of 4 (4-5) glaucoma medications to a median of 12 (10.5-14.5) mmHg on a median of 2 (0-2) medications at last follow-up after surgery (p = 0.043 for IOP and p = 0.042 for glaucoma medications). Median preoperative visual acuity [0.016 (0.008-0.1)] did not change significantly when compared to median visual acuity at last follow-up [0.016 (0.004-0.5)] (p = 0.59). Intraocular pressure control in patients with iridocorneal endothelial syndrome is challenging and may require multiple operations and revisions. Some modifications during glaucoma drainage implant surgery and use of EX-PRESS mini shunt in certain cases could offer an advantage in these patients.Entities:
Keywords: EX-PRESS mini shunt; Glaucoma; Iridocorneal endothelial syndrome
Mesh:
Year: 2016 PMID: 27495952 DOI: 10.1007/s10792-016-0317-1
Source DB: PubMed Journal: Int Ophthalmol ISSN: 0165-5701 Impact factor: 2.031