PURPOSE: To evaluate the efficacy and safety of the pars plana clip (PPC) in the Ahmed valve tube inserted via the pars plana in patients with secondary refractory glaucomas.Entities:
Keywords: Ahmed valve; pars plana clip; pars plana vitrectomy; refractory glaucoma
Year: 2010 PMID: 20463912 PMCID: PMC2866572 DOI: 10.2147/opth.s10005
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Figure 1Once the vitrectomy had been performed the Ahmed’s FP7 valve (New World Medical, Ranch Cucamoga, CA, USA) was purged with saline serum and sutured 15 mm from the corneal limbus with 5.0 nylon in either of the two superior quadrants.
Figure 4A patch of bovine pericardium Tutopatch (Tutogen Medical) was sutured over the pars plana clip with 8.0 nylon, and everything was then covered with the conjunctiva.
Summary of results
| 1 | Neovascular | R | 72 | 40 mmHg | 24 mmHg | Transitory hypotony |
| 2 | Neovascular | L | 64 | 35 mmHg | 20 mmHg | Transitory hypertension |
| 3 | Keratoplasty | L | 59 | 26 mmHg | 14 mmHg | Transitory hypotony |
| 4 | Traumatism | L | 44 | 30 mmHg | 12 mmHg | |
| 5 | Neovascular | R | 70 | 38 mmHg | 18 mmHg | |
| 6 | Uveitis | R | 36 | 24 mmHg | 12 mmHg | Transitory hypotony |
| 7 | Uveitis | L | 54 | 34 mmHg | 13 mmHg | Transitory hypertension |
| 8 | Keratoplasty | R | 62 | 32 mmHg | 15 mmHg | |
| 9 | Traumatism | L | 49 | 32 mmHg | 14 mmHg | |
| 10 | Uveitis | R | 34 | 29 mmHg | 18 mmHg |