Literature DB >> 10437976

Reliability of EMG spectral parameters in repeated measurements of back muscle fatigue.

B Elfving1, G Németh, I Arvidsson, M Lamontagne.   

Abstract

The change in median frequency of the power spectrum of the electromyographic (EMG) signal may be used as a measure of muscle fatigue. The reliability of the median frequency parameters was investigated for EMG-recording sites at L1 and L5 right and left on the erector spinae. The reliability of subjective fatigue ratings of the back muscles (Borg CR-10 scale) and of maximal trunk extension torque (MVC) was also investigated. Eleven subjects with healthy backs performed a 45-s isometric trunk extension at 80% of MVC twice a day, on three different days. Two-factor analysis of variance was made to obtain the different variances from which the standard error of measurement (SEM) and the intra class correlation coefficient (ICC) were calculated. The SEM within-day was somewhat lower than that between-days. Both were about the same at all four electrode sites. The 95% confidence interval for the studied variables was for the initial median frequency +/- 10 Hz, for the slope +/- 0.4-0.5%/s, for the MVC +/- 36 Nm and for the Borg ratings +/- 1.6. We conclude that, with the presently used method, changes or differences within these limits should be regarded as normal variability. The slope may be of limited value because of its large variability. Whether the low intraclass correlation coefficient for the EMG parameters in the presently studied test group implies a low potential in discriminating subjects with back pain can not be decisively concluded.

Entities:  

Mesh:

Year:  1999        PMID: 10437976     DOI: 10.1016/s1050-6411(98)00049-2

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  8 in total

1.  Influence of exercise intensity and joint angle on endurance time prediction of sustained submaximal isometric knee extensions.

Authors:  Sébastien Boyas; Arnaud Guével
Journal:  Eur J Appl Physiol       Date:  2010-12-03       Impact factor: 3.078

2.  The use of non-amplitude components of the myoelectric signal in identifying differences in function between the low back injured and controls.

Authors:  Gregory J Lehman
Journal:  J Can Chiropr Assoc       Date:  2004-09

3.  Muscle thickness changes during abdominal hollowing: an assessment of between-day measurement error in controls and patients with chronic low back pain.

Authors:  Anne F Mannion; Natascha Pulkovski; Deborah Gubler; Mark Gorelick; David O'Riordan; Thanasis Loupas; Peter Schenk; Hans Gerber; Haiko Sprott
Journal:  Eur Spine J       Date:  2008-01-15       Impact factor: 3.134

4.  Strength and fatigability of the dominant and nondominant hip abductors.

Authors:  Cale Jacobs; Timothy L Uhl; Matt Seeley; Wes Sterling; Larry Goodrich
Journal:  J Athl Train       Date:  2005 Jul-Sep       Impact factor: 2.860

5.  The potential use of spectral electromyographic fatigue as a screening and outcome monitoring tool of sarcopenic back muscle alterations.

Authors:  Thomas Kienbacher; Richard Habenicht; Christian Starek; Patrick Mair; Markus Wolf; Birgit Paul; Sara Riegler; Josef Kollmitzer; Gerold Ebenbichler
Journal:  J Neuroeng Rehabil       Date:  2014-07-02       Impact factor: 4.262

6.  Convergent Validity of Ratings of Perceived Exertion During Resistance Exercise in Healthy Participants: A Systematic Review and Meta-Analysis.

Authors:  John W D Lea; Jamie M O'Driscoll; Sabina Hulbert; James Scales; Jonathan D Wiles
Journal:  Sports Med Open       Date:  2022-01-08

7.  RELIABILITY AND VALIDITY OF THE HIP ABDUCTOR ISOMETRIC ENDURANCE TEST: A NEW METHOD TO ASSESS THE ENDURANCE OF THE HIP ABDUCTORS.

Authors:  Joachim Van Cant; Christine Detrembleur; Philippe Mahaudens; Véronique Feipel
Journal:  Int J Sports Phys Ther       Date:  2020-04

8.  A reliability of electromyographic normalization methods for the infraspinatus muscle in healthy subjects.

Authors:  Sung-Min Ha; Heon-Seock Cynn; Oh-Yun Kwon; Kyue-Nam Park; Gyoung-Mo Kim
Journal:  J Hum Kinet       Date:  2013-03-28       Impact factor: 2.193

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.