| Literature DB >> 23717356 |
Sung-Min Ha1, Heon-Seock Cynn, Oh-Yun Kwon, Kyue-Nam Park, Gyoung-Mo Kim.
Abstract
The purpose of this study was to examine the test-retest reliability of normalization methods for the infraspinatus muscle in a group of healthy subjects. Twelve healthy subjects (male=8, female=4) performed the maximal voluntary isometric contraction (MVIC) with examiner`s resistance, MVIC with a digital tension-meter (MVIC-DT), and sub-MVIC methods. Surface electromyography (EMG) signals were recorded from the infraspinatus muscles according to normalization methods. Reliability was analyzed using the intra-class coefficient (ICC), standard error of measurement (SEM), and minimal detectable difference (MDD). The results of the present study demonstrated that the sub-MVIC method has excellent test-retest reliability (ICC=0.92) with a relatively small SEM (5.9 mV) and MDD95 (16.4 mV), compared to MVIC-DT (ICC=0.73; SEM=11.2 mV; MDD95: 31 mV) and MVIC-E (ICC=0.5; SEM=15.7 mV; MDD95: 43.6 mV). These findings provide evidence that sub-MVIC is more appropriate for comparing the EMG activity for the infraspinatus muscle as a normalization method. If MVIC for normalization is needed, MVIC-DT is more appropriate than MVIC-E.Entities:
Keywords: electromyography; infraspinatus muscle; normalization; reliability
Year: 2013 PMID: 23717356 PMCID: PMC3661896 DOI: 10.2478/hukin-2013-0007
Source DB: PubMed Journal: J Hum Kinet ISSN: 1640-5544 Impact factor: 2.193
Characteristics of the subjects (N=12)
| 170.7 ± 7.3 | 174.9 ± 4.5 | 162.3 ± 2.1 | 0.00 | |
| 68.5 ± 15.5 | 76.6 ± 12.2 | 52.3 ± 1.7 | 0.03 | |
| 26.0 ± 4.5 | 29.0 ± 3.1 | 21.3 ± 0.5 | 0.01 |
Figure 1Testing Position: A: MVIC-E (maximal voluntary isometric contraction with examiner’s resistance); B: MVIC-DT (maximal voluntary isometric contraction with digital tension-meter); C: Sub-MVIC (sub-maximal voluntary isometric contraction)).
Test-retest ICC scores, SEM, and MDD95 among three methods.
| MVIC-E | MVIC-DT | Sub-MVIC | |
|---|---|---|---|
| ICC | 0.42 | 0.73 | 0.98 |
| SEM | 14.5 mV | 6.3 mV | 1.3 mV |
| MDD95 | 40.3 mV | 17.3 mV | 3.5 mV |
ICC = intraclass correlation coefficient; MDD = minimal detectable difference; SEM = standard error of measurement; MVIC-E = maximal voluntary isometric contraction with examiner`s resistance; MVIC-DT = maximal voluntary isometric contraction with digital tension-meter; Sub-MVIC = sub-maximal voluntary isometric contraction.
The force data using a digital tension meter.
| MVIC-DT | Sub-MVIC | |||
|---|---|---|---|---|
|
| ||||
| 1st trial | 2nd trial | 1st trial | 2nd trial | |
| Force (kg) | 56±14.9 | 54.1±15.4 | 32.4±8.2 | 32.3±8.5 |
MVIC-DT = maximal voluntary isometric contraction with digital tension-meter; Sub-MVIC = sub-maximal voluntary isometric contraction.