Literature DB >> 10398976

Automatic vessel segmentation using active contours in cine phase contrast flow measurements.

S Kozerke1, R Botnar, S Oyre, M B Scheidegger, E M Pedersen, P Boesiger.   

Abstract

The segmentation of images obtained by cine magnetic resonance (MR) phase contrast velocity mapping using manual or semi-automated methods is a time consuming and observer-dependent process that still hampers the use of flow quantification in a clinical setting. A fully automatic segmentation method based on active contour model algorithms for defining vessel boundaries has been developed. For segmentation, the phase image, in addition to the magnitude image, is used to address image distortions frequently seen in the magnitude image of disturbed flow fields. A modified definition for the active contour model is introduced to reduce the influence of missing or spurious edge information of the vessel wall. The method was evaluated on flow phantom data and on in vivo images acquired in the ascending aorta of humans. Phantom experiments resulted in an error of 0.8% in assessing the luminal area of a flow phantom equipped with an artificial heart valve. Blinded evaluation of the volume flow rates from automatic vs. manual segmentation of gradient echo (FFE) phase contrast images obtained in vivo resulted in a mean difference of -0.9 +/- 3%. The mean difference from automatic vs. manual segmentation of images acquired with a hybrid phase contrast sequence (TFEPI) within a single breath-hold was -0.9 +/- 6%.

Entities:  

Mesh:

Year:  1999        PMID: 10398976     DOI: 10.1002/(sici)1522-2586(199907)10:1<41::aid-jmri6>3.0.co;2-j

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  14 in total

1.  Methods for generating high-resolution structural models from electron microscope tomography data.

Authors:  David B Ress; Mark L Harlow; Robert M Marshall; Uel J McMahan
Journal:  Structure       Date:  2004-10       Impact factor: 5.006

2.  Three-dimensional reconstruction of cranial defect using active contour model and image registration.

Authors:  Yuan-Lin Liao; Chia-Feng Lu; Yung-Nien Sun; Chieh-Tsai Wu; Jiann-Der Lee; Shih-Tseng Lee; Yu-Te Wu
Journal:  Med Biol Eng Comput       Date:  2010-12-03       Impact factor: 2.602

3.  Semiautomatic analysis of phase contrast magnetic resonance imaging of cerebrospinal fluid flow through the aqueduct of Sylvius.

Authors:  Yudy Natalia Flórez; David Moratal; Juana Forner; Luis Martí-Bonmatí; Estanislao Arana; Ulises Guajardo-Hernández; José Millet-Roig
Journal:  MAGMA       Date:  2006-05-09       Impact factor: 2.310

4.  Fully automated tool to identify the aorta and compute flow using phase-contrast MRI: validation and application in a large population based study.

Authors:  Akshay Goel; Roderick McColl; Kevin S King; Anthony Whittemore; Ronald M Peshock
Journal:  J Magn Reson Imaging       Date:  2013-09-30       Impact factor: 4.813

5.  [The use of cross-sectional imaging modalities in the diagnosis of valvular heart disease].

Authors:  M Gutberlet; H Abdul-Khaliq; H Stobbe; M Fröhlich; B Spors; F Knollmann; P Lange; R Hetzer; R Felix
Journal:  Z Kardiol       Date:  2001-12

6.  Pseudo continuous arterial spin labeling quantification in anemic subjects with hyperemic cerebral blood flow.

Authors:  Adam Bush; Yaqiong Chai; So Young Choi; Lena Vaclavu; Scott Holland; Aart Nederveen; Thomas Coates; John Wood
Journal:  Magn Reson Imaging       Date:  2017-12-09       Impact factor: 2.546

7.  Reproducibility and accuracy of automated measurement for dynamic arterial lumen area by cardiovascular magnetic resonance.

Authors:  Clare E Jackson; Cheerag C Shirodaria; Justin M S Lee; Jane M Francis; Robin P Choudhury; Keith M Channon; J Alison Noble; Stefan Neubauer; Matthew D Robson
Journal:  Int J Cardiovasc Imaging       Date:  2009-09-25       Impact factor: 2.357

8.  Cyclic motion encoding for enhanced MR visualization of slip interfaces.

Authors:  Yogesh K Mariappan; Kevin J Glaser; Armando Manduca; Richard L Ehman
Journal:  J Magn Reson Imaging       Date:  2009-10       Impact factor: 4.813

9.  Blood flow distribution in a large series of patients having the Fontan operation: a cardiac magnetic resonance velocity mapping study.

Authors:  Kevin K Whitehead; Kartik S Sundareswaran; W James Parks; Matthew A Harris; Ajit P Yoganathan; Mark A Fogel
Journal:  J Thorac Cardiovasc Surg       Date:  2009-04-25       Impact factor: 5.209

10.  Optimum fuzzy filters for phase-contrast magnetic resonance imaging segmentation.

Authors:  Kartik S Sundareswaran; David H Frakes; Mark A Fogel; Dennis D Soerensen; John N Oshinski; Ajit P Yoganathan
Journal:  J Magn Reson Imaging       Date:  2009-01       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.