Literature DB >> 16779563

Semiautomatic analysis of phase contrast magnetic resonance imaging of cerebrospinal fluid flow through the aqueduct of Sylvius.

Yudy Natalia Flórez1, David Moratal, Juana Forner, Luis Martí-Bonmatí, Estanislao Arana, Ulises Guajardo-Hernández, José Millet-Roig.   

Abstract

OBJECTIVE: Quantification of the cerebrospinal fluid (CSF) flow through the aqueduct of Sylvius by means of magnetic resonance imaging (MRI) is subject to interobserver variability due to the region of interest (ROI) selection. Our objective is to develop a semiautomatic measurement method to achieve reproducible quantitative analysis of CSF flow rate and stroke volume.
MATERIAL AND METHODS: MR examinations were performed using a 1.5 T scanner with a phase contrast sequence (velocity encoding [V(enc)] of 20 cm/s, FOV = 160, 3 mm slice thickness, image matrix size = 256x256, TR = 53 ms, TE = 11 ms, NSA = 2, flip angle = 15 degrees and 23 frames per cardiac cycle with peripheral retrospective pulse gating). Our method was developed using MATLAB R7. Errors introduced by background offset and possible aliased pixels were automatically detected and corrected if necessary in order to calculate the flow parameters that characterize CSF dynamics. The semiautomatic seed method reproducibility was evaluated and compared with the radius method by two observers analysing 21 healthy subjects.
RESULTS: The measurements using the semiautomatic seed method reduced the interobservers variability (intra-class correlation [ICC] = 1.0 for stroke volume and for volumetric flow rate) versus the radius method (ICC = 0.46 for stroke volume and 0.65 for flow rate). Normal stroke volume (39.19 +/- 20.13 microl/cycle), flow rate (3.81 +/- 2.81 ml/min), maximal mean systolic velocity (5.27 +/- 1.3 cm/s) and maximal mean diastolic velocity (4.20 +/- 1.4 cm/s) were calculated with the half moon and aliasing corrected seed method.
CONCLUSIONS: Semiautomatic measurements (seed method with half moon background and aliasing correction) allow a generalization of the calculus of flow parameters with great consistency and independency of the operator.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16779563     DOI: 10.1007/s10334-006-0030-6

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  28 in total

1.  PUBS: pulsatility-based segmentation of lumens conducting non-steady flow.

Authors:  Noam Alperin; Sang Hoon Lee
Journal:  Magn Reson Med       Date:  2003-05       Impact factor: 4.668

2.  Intracranial fluid dynamics in normal and hydrocephalic states: systems analysis with phase-contrast magnetic resonance imaging.

Authors:  Giovanni de Marco; Ilana Idy-Peretti; Anne Didon-Poncelet; Olivier Baledent; Fannie Onen; Marie Cécile Henry Feugeas
Journal:  J Comput Assist Tomogr       Date:  2004 Mar-Apr       Impact factor: 1.826

3.  Measurement of cerebrospinal fluid flow at the cerebral aqueduct by use of phase-contrast magnetic resonance imaging: technique validation and utility in diagnosing idiopathic normal pressure hydrocephalus.

Authors:  Patrick H Luetmer; John Huston; Jonathan A Friedman; Geoffrey R Dixon; Ronald C Petersen; Clifford R Jack; Robyn L McClelland; Michael J Ebersold
Journal:  Neurosurgery       Date:  2002-03       Impact factor: 4.654

4.  Quantitative assessment of cerebrospinal fluid hydrodynamics using a phase-contrast cine MR image in hydrocephalus.

Authors:  D S Kim; J U Choi; R Huh; P H Yun; D I Kim
Journal:  Childs Nerv Syst       Date:  1999-09       Impact factor: 1.475

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

Review 6.  Flow quantification and analysis methods.

Authors:  N J Pelc
Journal:  Magn Reson Imaging Clin N Am       Date:  1995-08       Impact factor: 2.266

7.  Analysis of cerebrospinal fluid flow waveforms with gated phase-contrast MR velocity measurements.

Authors:  R A Bhadelia; A R Bogdan; S M Wolpert
Journal:  AJNR Am J Neuroradiol       Date:  1995-02       Impact factor: 3.825

8.  The intraclass correlation coefficient as a measure of reliability.

Authors:  J J Bartko
Journal:  Psychol Rep       Date:  1966-08

9.  Cerebrospinal fluid dynamics and relation with blood flow: a magnetic resonance study with semiautomated cerebrospinal fluid segmentation.

Authors:  O Balédent; M C Henry-Feugeas; I Idy-Peretti
Journal:  Invest Radiol       Date:  2001-07       Impact factor: 6.016

10.  Supratentorial cerebrospinal fluid production rate in healthy adults: quantification with two-dimensional cine phase-contrast MR imaging with high temporal and spatial resolution.

Authors:  Teng-Yi Huang; Hsiao-Wen Chung; Ming-Yen Chen; Lung-Hui Giiang; Shy-Chyi Chin; Chang-Shin Lee; Cheng-Yu Chen; Yi-Jui Liu
Journal:  Radiology       Date:  2004-11       Impact factor: 11.105

View more
  3 in total

1.  Inspiration is the major regulator of human CSF flow.

Authors:  Steffi Dreha-Kulaczewski; Arun A Joseph; Klaus-Dietmar Merboldt; Hans-Christoph Ludwig; Jutta Gärtner; Jens Frahm
Journal:  J Neurosci       Date:  2015-02-11       Impact factor: 6.167

Review 2.  Guide to preclinical models used to study the pathophysiology of idiopathic intracranial hypertension.

Authors:  Zerin Alimajstorovic; Connar S J Westgate; Rigmor H Jensen; Sajedeh Eftekhari; James Mitchell; Vivek Vijay; Senali Y Seneviratne; Susan P Mollan; Alexandra J Sinclair
Journal:  Eye (Lond)       Date:  2020-01-02       Impact factor: 3.775

3.  Assessing test-retest reliability of phase contrast MRI for measuring cerebrospinal fluid and cerebral blood flow dynamics.

Authors:  Ashwin R Sakhare; Giuseppe Barisano; Judy Pa
Journal:  Magn Reson Med       Date:  2019-04-25       Impact factor: 3.737

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.