Literature DB >> 10396835

Technique of distortion correction in endoscopic images using a polynomial expansion.

K V Asari1, S Kumar, D Radhakrishnan.   

Abstract

A new technique to correct non-linear distortion of endoscopic images based on L2-norm approximation is proposed. A mathematical model is defined that maps the endoscopic images from the distorted image plane onto an undistorted image plane. A set of model parameters is defined, consisting of the image distortion centre, corrected centre and expansion polynomial coefficients representing radial distortion correction. A new method to find the image distortion centre based on a curvature criterion is also developed. The expansion coefficients are estimated on the basis of the degree of straightness of the grid lines in an image of a test grid consisting of dots in a rectangular pattern. The corrected image centre is computed by ensuring that the distances between neighbouring test dots of different grid lines in the corrected image are the same. The quantitative data providing the results and errors of the expansion characteristics are presented. The performance of the proposed distortion correction algorithm is validated with grid patterns of different orientations. The algorithm is also applied to typical endoscopic images, and the results are presented. The high-speed response of the proposed technique is a key step towards on-line camera calibration.

Mesh:

Year:  1999        PMID: 10396835     DOI: 10.1007/bf02513259

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  3 in total

1.  A new method for distortion correction of electronic endoscope images.

Authors:  H Haneishi; Y Yagihashi; Y Miyake
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

2.  Correction of distortion in endoscope images.

Authors:  W E Smith; N Vakil; S A Maislin
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

3.  Video endoscopy testbox.

Authors:  L C Phin; K J Maxted; W Richardson; J Macleod
Journal:  Med Biol Eng Comput       Date:  1996-11       Impact factor: 2.602

  3 in total
  5 in total

1.  Real-time automatic extraction of lumen region and boundary from endoscopic images.

Authors:  S Kumar; K V Asari; D Radhakrishnan
Journal:  Med Biol Eng Comput       Date:  1999-09       Impact factor: 2.602

2.  Arthroscopic image distortion-part I: the effect of lens and viewing angles in a 2-dimensional in vitro model.

Authors:  Yuichi Hoshino; Benjamin B Rothrauff; Daniel Hensler; Freddie H Fu; Volker Musahl
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-24       Impact factor: 4.342

3.  Arthroscopic image distortion-part II: the effect of lens angle and portal location in a 3D knee model.

Authors:  Yuichi Hoshino; Benjamin B Rothrauff; Daniel Hensler; Freddie H Fu; Volker Musahl
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-24       Impact factor: 4.342

4.  Measurements of knee morphometrics using MRI and arthroscopy: a comparative study between ACL-injured and non-injured subjects.

Authors:  Sharon H A Vrooijink; Femke Wolters; Carola F Van Eck; Freddie H Fu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-07       Impact factor: 4.342

5.  Light intensity distribution in images from rigid endoscopes used in minimal access sinus surgery.

Authors:  Eric W Abel; Nikolaos Fotiadis; Paul S White
Journal:  Laryngoscope Investig Otolaryngol       Date:  2021-11-23
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.