Parallel conductance determination in cardiac volumetry using dilution manoeuvres: theoretical analysis and practical implications.

M C Herrera1, J M Olivera, M E Valentinuzzi.   

Abstract

Left ventricular volume calibration based on the conductance catheter depends on the correct determination of the parallel conductance (Gp). Baan's saline manoeuvre procedure leads to Gp by finding the end-systolic (Ges) and end-diastolic (Ged) conductances, for each beat of the dilution curve rising limb. After plotting such values in an xy-system, their linear regression is back-projected to intersect the identity line, so yielding an estimated Gp. The objective is to theoretically analyse all possible lines, Ges = aGed + b (Baan's line) and, based on experimental results, to establish their limitations. This was attained by calculating the regression lines using, first Ged = f1(Ges) and thereafter, Ges = f2(Ged), which led to two values, Gp2 and Gp1, for the parallel conductance. The morphology of the saline curve was also modified to assess its effect on the extrapolation. Multiple dilutions were recorded in eight experimental dogs injecting different concentrations. Each curve was classified according to the maximum change (VAR) reached by the total average conductance. Over 138 manoeuvres, 276 regressions were processed yielding correlations higher than 0.65. Of this total, 92.4% gave positive parallel conductances. The rest produced negative values and, thus, were neglected. If the two (Ged, Ges) statistical relationships were ideal, they should yield Gp = Gp1 = Gp2; however, there were differences which, when Gp1 was studied against Gp2, led to: Gp1 = 0.97 Gp2 + 0.055, with r = 0.9476, and n = 85. The remaining 53 were discarded because either some Gp values were negative, or the correlation of Ges which Ged (or vice versa) was < 0.85, and/or VAR < 15%; the two latter conditions were found necessary for reliable calibration. Baan's line high correlation is not a unique condition to ensure the accuracy and precision of Gp determination because the slope a depends on VAR and, thus, different intersections with the identity line may be obtained. Its recommended that manoeuvres be used with at least eight data points, with VAR > 15% and, finally, with (Ges, Ged) correlation better than 0.85. Theoretical analysis of Baan's line offers a reference frame, which contains only a limited number of practical possibilities.

Entities:  

Mesh:

Year:  1999        PMID: 10396820     DOI: 10.1007/bf02513284

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  19 in total

1.  Accuracy of the conductance catheter for measurement of ventricular volumes seen clinically: effects of electric field homogeneity and parallel conductance.

Authors:  C C Wu; T C Skalak; T R Schwenk; C M Mahler; A Anne; P W Finnerty; H L Haber; R M Weikle; M D Feldman
Journal:  IEEE Trans Biomed Eng       Date:  1997-04       Impact factor: 4.538

2.  Does volume catheter parallel conductance vary during a cardiac cycle?

Authors:  E B Lankford; D A Kass; W L Maughan; A A Shoukas
Journal:  Am J Physiol       Date:  1990-06

3.  Validation of the saline-dilution method for measuring cardiac output by simultaneous measurement with a perivascular electromagnetic flowprobe.

Authors:  W D Voorhees; J D Bourland; M L Lamp; J C Mullikin; L A Geddes
Journal:  Med Instrum       Date:  1985 Jan-Feb

4.  Cardiac output using an electrically calibrated flow-through conductivity cell.

Authors:  L A Geddes; E Peery; R Steinberg
Journal:  J Appl Physiol       Date:  1974-12       Impact factor: 3.531

5.  Conductance catheter measurement of left ventricular volume: evidence for nonlinearity within cardiac cycle.

Authors:  R S Szwarc; D Laurent; P R Allegrini; H A Ball
Journal:  Am J Physiol       Date:  1995-04

6.  Volume profiles obtained by a conductimetric method.

Authors:  M C Herrera; M E Valentinuzzi; J M Olivera
Journal:  J Biomed Eng       Date:  1993-07

7.  Right-side cardiac output determined with a newly developed catheter-tip resistivity probe using saline indicator.

Authors:  D S Grubbs; L A Geddes
Journal:  Jpn Heart J       Date:  1984-01

8.  Computation of the input impedances of a catheter for cardiac volumetry.

Authors:  G Mur; J Baan
Journal:  IEEE Trans Biomed Eng       Date:  1984-06       Impact factor: 4.538

9.  Left ventricular parallel conductance during cardiac cycle in children with congenital heart disease.

Authors:  P A White; R R Chaturvedi; D Shore; C Lincoln; R S Szwarc; A J Bishop; P J Oldershaw; A N Redington
Journal:  Am J Physiol       Date:  1997-07

10.  Extrinsic factors influencing left ventricular conductance in situ.

Authors:  M M Amirhamzeh; C X Jia; H M Spotnitz
Journal:  Circulation       Date:  1994-11       Impact factor: 29.690

View more
  1 in total

1.  Measurement of peak esophageal luminal cross-sectional area utilizing nadir intraluminal impedance.

Authors:  A Zifan; M Ledgerwood-Lee; R K Mittal
Journal:  Neurogastroenterol Motil       Date:  2015-04-30       Impact factor: 3.598

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.