Literature DB >> 9249503

Left ventricular parallel conductance during cardiac cycle in children with congenital heart disease.

P A White1, R R Chaturvedi, D Shore, C Lincoln, R S Szwarc, A J Bishop, P J Oldershaw, A N Redington.   

Abstract

This study examines the accuracy of the conductance catheter technique and, in particular, parallel conductance [expressed as offset volume (Vc)] changes during the cardiac cycle in the human left ventricle. Two groups of patients were assessed: group 1, with an open atrial septal defect, and group 2, with an interventricular communication. In a subgroup, pre- and postoperative data were compared to assess the possible impact of shunting or anatomic considerations on our measurements. Vc is normally obtained by a saline-dilution technique previously described by Baan et al. [Vc(Baan); J. Baan, E. T. Van der velde, H. G. Debruin, G. J. Smeenk, J. Koops, A. D. Van Dijk, D. Temmerman, P. J. Senden, and B. Buis. Circulation 70: 812-823, 1984]. This does not take into account potential changes during the cardiac cycle. Four cardiac cycles were taken from the hypertonic saline washin and were divided into six equal isochrones between the maximum and minimum first derivatives of left ventricular pressure (dP/dtmax and dP/dtmin, respectively). The apparent ventricular volume was regressed against stroke volume for the corresponding cardiac cycle. The volume at the gamma-intercept corresponds to the Vc at each time interval [Vc(t)]. In group 1, there was a variation in Vc(t) during systole, but the temporal changes were quite small, on the order of 4.28% (SD = 5.18%) of total corrected end-diastolic volume (mean maximal variation of 2.60 ml). Furthermore, the value of Vc obtained at dP/dtmax was not significantly different from that obtained at dP/dtmin. For group 2 as a whole, mean Vc(Baan) did not change significantly with ventricular septal defect closure (preoperative, 8.85 +/- 11.1 ml; postoperative, 9.82 +/- 11.84 ml). Group 2 children also exhibited a systolic cyclical variation in Vc(t) similar to group 1. Finally, Vc(t) as a percentage of end-diastolic volume was no different when group 1 and group 2 were compared. We conclude that in the left ventricle, even in the presence of a left-to-right shunt, there is a small but insignificant difference in parallel conductance during ventricular ejection. The magnitude of this cyclical change does not preclude ventricular volume measurement in congenital heart disease by the conductance catheter technique.

Entities:  

Mesh:

Year:  1997        PMID: 9249503     DOI: 10.1152/ajpheart.1997.273.1.H295

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  3 in total

1.  Parallel conductance determination in cardiac volumetry using dilution manoeuvres: theoretical analysis and practical implications.

Authors:  M C Herrera; J M Olivera; M E Valentinuzzi
Journal:  Med Biol Eng Comput       Date:  1999-03       Impact factor: 2.602

2.  Inhibition of nitric oxide synthesis improves left ventricular contractility in neonatal pigs late after cardiopulmonary bypass.

Authors:  R R Chaturvedi; V E Hjortdal; E V Stenbog; H B Ravn; P White; T D Christensen; A B Thomsen; J Pedersen; K E Sorensen; A N Redington
Journal:  Heart       Date:  1999-12       Impact factor: 5.994

3.  Acute effects of vasoactive medications in patients with parallel circulation awaiting hybrid or Norwood procedure.

Authors:  Emily Hendon; Jennifer Kane; Gina M Golem; Amanda McBroom; Saul Flores; Joshua Wong; Enrique G Villarreal; Rohit S Loomba
Journal:  Ann Pediatr Cardiol       Date:  2022-06-14
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.