Literature DB >> 10371457

Resolution enhancement in single-shot imaging using simultaneous acquisition of spatial harmonics (SMASH).

M A Griswold1, P M Jakob, Q Chen, J W Goldfarb, W J Manning, R R Edelman, D K Sodickson.   

Abstract

Spatial resolution in single-shot imaging is limited by signal attenuation due to relaxation of transverse magnetization. This effect can be reduced by minimizing acquisition times through the use of short interecho spacings. However, the minimum interecho spacing is constrained by limits on gradient switching rates, radiofrequency (RF) power deposition and RF pulse length. Recently, simultaneous acquisition of spatial harmonics (SMASH) has been introduced as a method to acquire magnetic resonance images at increased speeds using a reduced number of phase-encoding gradient steps by extracting spatial information contained in an RF coil array. In this study, it is shown that SMASH can be used to reduce the effects of relaxation, resulting in single-shot images with increased spatial resolution without increasing imaging time. After a brief theoretical discussion, two strategies to reduce signal attenuation and increase spatial resolution in single-shot imaging are introduced and their performance is evaluated in phantom studies. In vivo single-shot echoplanar imaging (EPI), BURST, and half-Fourier single-shot turbo spin-echo (HASTE) images are then presented demonstrating the practical implementation of these resolution enhancement strategies. Images acquired with SMASH show increased spatial resolution and improved image quality when compared with images obtained with the conventional acquisitions. The general principles presented for imaging with SMASH can also be applied to other partially parallel imaging techniques.

Mesh:

Year:  1999        PMID: 10371457     DOI: 10.1002/(sici)1522-2594(199906)41:6<1236::aid-mrm21>3.0.co;2-t

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  32 in total

1.  SMASH imaging with an eight element multiplexed RF coil array.

Authors:  J A Bankson; M A Griswold; S M Wright; D K Sodickson
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

2.  [Feasibilities and limitations of high field parallel MRI].

Authors:  R M Heidemann; M A Griswold; M Müller; F Breuer; M Blaimer; B Kiefer; M Schmitt; P M Jakob
Journal:  Radiologe       Date:  2004-01       Impact factor: 0.635

3.  Comparison of three multichannel transmit/receive radiofrequency coil configurations for anatomic and functional cardiac MRI at 7.0T: implications for clinical imaging.

Authors:  Lukas Winter; Peter Kellman; Wolfgang Renz; Andreas Gräßl; Fabian Hezel; Christof Thalhammer; Florian von Knobelsdorff-Brenkenhoff; Valeriy Tkachenko; Jeanette Schulz-Menger; Thoralf Niendorf
Journal:  Eur Radiol       Date:  2012-06-01       Impact factor: 5.315

4.  HYPR TOF: time-resolved contrast-enhanced intracranial MR angiography using time-of-flight as the spatial constraint.

Authors:  Yijing Wu; Steven R Kecskemeti; Kevin Johnson; Kang Wang; Howard Rowley; Oliver Wieben; Charles Mistretta; Patrick Turski
Journal:  J Magn Reson Imaging       Date:  2011-02-01       Impact factor: 4.813

5.  Intrinsic signal amplification in the application of 2D SENSE parallel imaging to 3D contrast-enhanced elliptical centric MRA and MRV.

Authors:  Stephen J Riederer; Houchun Harry Hu; David G Kruger; Clifton R Haider; Norbert G Campeau; John Huston
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

6.  The impact of EPI voxel size on SNR and BOLD sensitivity in the anterior medio-temporal lobe: a comparative group study of deactivation of the Default Mode.

Authors:  Simon D Robinson; Jürgen Pripfl; Herbert Bauer; Ewald Moser
Journal:  MAGMA       Date:  2008-07-26       Impact factor: 2.310

Review 7.  A brief review of parallel magnetic resonance imaging.

Authors:  Robin M Heidemann; Ozkan Ozsarlak; Paul M Parizel; Johan Michiels; Berthold Kiefer; Vladimir Jellus; Mathias Müller; Felix Breuer; Martin Blaimer; Mark A Griswold; Peter M Jakob
Journal:  Eur Radiol       Date:  2003-08-27       Impact factor: 5.315

8.  View angle tilting echo planar imaging for distortion correction.

Authors:  Sinyeob Ahn; Xiaoping P Hu
Journal:  Magn Reson Med       Date:  2011-12-28       Impact factor: 4.668

9.  Neuroimaging brainstem circuitry supporting cardiovagal response to pain: a combined heart rate variability/ultrahigh-field (7 T) functional magnetic resonance imaging study.

Authors:  Roberta Sclocco; Florian Beissner; Gaelle Desbordes; Jonathan R Polimeni; Lawrence L Wald; Norman W Kettner; Jieun Kim; Ronald G Garcia; Ville Renvall; Anna M Bianchi; Sergio Cerutti; Vitaly Napadow; Riccardo Barbieri
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2016-05-13       Impact factor: 4.226

10.  Ultrafast bold fMRI using single-shot spin-echo echo planar imaging.

Authors:  Saïd Boujraf; Paul Summers; Faouzi Belahsen; Klaas Prüssmann; Spyros Kollias
Journal:  J Med Phys       Date:  2009-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.