Literature DB >> 10332849

A novel fast split-echo multi-shot diffusion-weighted MRI method using navigator echoes.

C F Williams1, T W Redpath, D G Norris.   

Abstract

Difficulties in obtaining diffusion-weighted images of acceptable quality using conventional hardware and in a reasonable time have hindered the clinical application of diffusion-weighted magnetic resonance imaging (DWI). Diffusion-weighted fast spin-echo (FSE) sequences offer the possibility of fast DWI on standard hardware without the susceptibility problems associated with echoplanar imaging. However, motion in the presence of diffusion-sensitizing gradients can prevent fulfilment of the Meiboom Gill phase condition, leading to destructive interference between echo components and consequent signal losses. A recently proposed single-shot FSE sequence employed split-echo acquisition to address this problem. However, in a segmented FSE sequence, phase errors differ between successive echo trains, causing "ghosting" in the diffusion-weighted images that are not eliminated by split-echo acquistion alone. A DWI technique is presented that combines split-echo acquisition with navigator echo phase correction in a segmented FSE sequence. It is shown to be suitable for diffusion measurements in vivo using standard hardware.

Mesh:

Year:  1999        PMID: 10332849     DOI: 10.1002/(sici)1522-2594(199904)41:4<734::aid-mrm12>3.0.co;2-3

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Structure tensor informed fibre tractography at 3T.

Authors:  Kwok-Shing Chan; David G Norris; José P Marques
Journal:  Hum Brain Mapp       Date:  2018-07-21       Impact factor: 5.038

2.  Murine diffusion imaging using snapshot interleaved EPI acquisition at 7T.

Authors:  David N Guilfoyle; Scott Gerum; Jan Hrabe
Journal:  J Neurosci Methods       Date:  2011-04-30       Impact factor: 2.390

Review 3.  Diffusion tensor imaging and beyond.

Authors:  Jacques-Donald Tournier; Susumu Mori; Alexander Leemans
Journal:  Magn Reson Med       Date:  2011-04-05       Impact factor: 4.668

4.  Volumetric and multispectral DWI near metallic implants using a non-linear phase Carr-Purcell-Meiboom-Gill diffusion preparation.

Authors:  Philip K Lee; Daehyun Yoon; Jesse K Sandberg; Shreyas S Vasanawala; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2022-01-11       Impact factor: 4.668

Review 5.  Diffusion-weighted breast MRI: Clinical applications and emerging techniques.

Authors:  Savannah C Partridge; Noam Nissan; Habib Rahbar; Averi E Kitsch; Eric E Sigmund
Journal:  J Magn Reson Imaging       Date:  2016-09-30       Impact factor: 4.813

6.  Diffusion-weighted Renal MRI at 9.4 Tesla Using RARE to Improve Anatomical Integrity.

Authors:  Joāo Dos Santos Periquito; Katharina Paul; Till Huelnhagen; Min-Chi Ku; Yiyi Ji; Kathleen Cantow; Thomas Gladytz; Dirk Grosenick; Bert Flemming; Erdmann Seeliger; Sonia Waiczies; Thoralf Niendorf; Andreas Pohlmann
Journal:  Sci Rep       Date:  2019-12-23       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.