Literature DB >> 21557967

Murine diffusion imaging using snapshot interleaved EPI acquisition at 7T.

David N Guilfoyle1, Scott Gerum, Jan Hrabe.   

Abstract

Diffusion tensor imaging (DTI) is a powerful magnetic resonance imaging tool for quantitative assessment of white matter micro structure. The majority of DTI methods employ Echo Planar Imaging (EPI) because it is insensitive to motion. However, EPI suffers from distortions and signal losses induced by inhomogeneities in magnetic field susceptibility. This is particularly accentuated in murine imaging at very high magnetic fields. The purpose of this study is to demonstrate that a Snapshot Interleaved EPI acquisition block combined with a stimulated echo module for diffusion sensitization can be successfully used to obtain high quality DTI of a mouse brain at 7T. This technique preserves the EPI speed but reduces its susceptibility artifacts and signal losses. Signal to noise ratio is also reduced but remains higher than in the DTI acquisitions based on a fast low angle shot technique. In vivo results using this new approach are presented along with a full description of the methodology. Published by Elsevier B.V.

Entities:  

Mesh:

Year:  2011        PMID: 21557967      PMCID: PMC3112266          DOI: 10.1016/j.jneumeth.2011.04.011

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  22 in total

1.  Half-Fourier single-shot STEAM MRI.

Authors:  Jürgen Finsterbusch; Jens Frahm
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

2.  A novel fast split-echo multi-shot diffusion-weighted MRI method using navigator echoes.

Authors:  C F Williams; T W Redpath; D G Norris
Journal:  Magn Reson Med       Date:  1999-04       Impact factor: 4.668

3.  2D multislice and 3D MRI sequences are often equally sensitive.

Authors:  G Johnson; Y Z Wadghiri; D H Turnbull
Journal:  Magn Reson Med       Date:  1999-04       Impact factor: 4.668

4.  Quantitative measurements of proton spin-lattice (T1) and spin-spin (T2) relaxation times in the mouse brain at 7.0 T.

Authors:  David N Guilfoyle; Victor V Dyakin; Jacqueline O'Shea; Gaby S Pell; Joseph A Helpern
Journal:  Magn Reson Med       Date:  2003-03       Impact factor: 4.668

5.  Diffusion tensor imaging in fixed brain tissue at 7.0 T.

Authors:  David N Guilfoyle; Joseph A Helpern; Kelvin O Lim
Journal:  NMR Biomed       Date:  2003-04       Impact factor: 4.044

6.  Towards better MR characterization of neural tissues using directional diffusion kurtosis analysis.

Authors:  Edward S Hui; Matthew M Cheung; Liqun Qi; Ed X Wu
Journal:  Neuroimage       Date:  2008-04-30       Impact factor: 6.556

7.  The effect of bulk susceptibility on murine snapshot imaging at 7.0 T: a comparison of snapshot imaging techniques.

Authors:  S M Grieve; A M Blamire; P Styles
Journal:  Magn Reson Med       Date:  2000-05       Impact factor: 4.668

8.  MR diffusion tensor spectroscopy and imaging.

Authors:  P J Basser; J Mattiello; D LeBihan
Journal:  Biophys J       Date:  1994-01       Impact factor: 4.033

9.  Estimation of the effective self-diffusion tensor from the NMR spin echo.

Authors:  P J Basser; J Mattiello; D LeBihan
Journal:  J Magn Reson B       Date:  1994-03

10.  The spatial mapping of translational diffusion coefficients by the NMR imaging technique.

Authors:  D G Taylor; M C Bushell
Journal:  Phys Med Biol       Date:  1985-04       Impact factor: 3.609

View more
  3 in total

Review 1.  Translating glutamate: from pathophysiology to treatment.

Authors:  Daniel C Javitt; Darryle Schoepp; Peter W Kalivas; Nora D Volkow; Carlos Zarate; Kalpana Merchant; Mark F Bear; Daniel Umbricht; Mihaly Hajos; William Z Potter; Chi-Ming Lee
Journal:  Sci Transl Med       Date:  2011-09-28       Impact factor: 17.956

2.  Free-breathing 3D diffusion MRI for high-resolution hepatic metastasis characterization in small animals.

Authors:  Emeline J Ribot; Aurélien J Trotier; Charles R Castets; Benjamin Dallaudière; Eric Thiaudière; Jean-Michel Franconi; Sylvain Miraux
Journal:  Clin Exp Metastasis       Date:  2015-11-05       Impact factor: 5.150

3.  Fast diffusion tensor magnetic resonance imaging of the mouse brain at ultrahigh-field: aiming at cohort studies.

Authors:  Hans-Peter Müller; Ina Vernikouskaya; Albert C Ludolph; Jan Kassubek; Volker Rasche
Journal:  PLoS One       Date:  2012-12-28       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.