Literature DB >> 10331775

Fast 3D cardiac cine MR imaging.

M T Alley1, S Napel, Y Amano, D S Paik, R Y Shifrin, A Shimakawa, N J Pelc, R J Herfkens.   

Abstract

We describe a technique for three-dimensional cine MR imaging. By using short repetition times (TR) and interleaved slice encoding, volumetric cine data can be acquired throughout the cardiac cycle with a temporal resolution of approximately 80 msec. A T1-shortening agent is used to produce contrast between blood and myocardium. A comparison between the acquisition times of this and several other two-dimensional techniques is presented.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10331775     DOI: 10.1002/(sici)1522-2586(199905)9:5<751::aid-jmri21>3.0.co;2-7

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  11 in total

Review 1.  Review of new techniques in echocardiography and magnetic resonance imaging as applied to patients with congenital heart disease.

Authors:  D J Sahn; G W Vick
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

2.  Improved functional cardiac MR imaging using the intravascular contrast agent CLARISCAN.

Authors:  I Paetsch; H Thiele; B Schnackenburg; A Bornstedt; A Müller-York; J Schwab; E Fleck; E Nagel
Journal:  Int J Cardiovasc Imaging       Date:  2003-08       Impact factor: 2.357

3.  3D breath-held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI.

Authors:  Dana C Peters; Daniel B Ennis; Pratik Rohatgi; Mushabbar A Syed; Elliot R McVeigh; Andrew E Arai
Journal:  J Magn Reson Imaging       Date:  2004-09       Impact factor: 4.813

4.  Volumetric assessment of myocardial viability in rats using 3D double contrast enhanced T1 and T2-weighted MRI.

Authors:  C Chapon; F Franconi; L Lemaire; L Marescaux; P Legras; B Denizot; J-J Le Jeune
Journal:  MAGMA       Date:  2005-12-15       Impact factor: 2.310

5.  Compressed sensing reconstruction for whole-heart imaging with 3D radial trajectories: a graphics processing unit implementation.

Authors:  Seunghoon Nam; Mehmet Akçakaya; Tamer Basha; Christian Stehning; Warren J Manning; Vahid Tarokh; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-03-05       Impact factor: 4.668

6.  Improved cardiovascular flow quantification with time-resolved volumetric phase-contrast MRI.

Authors:  Albert Hsiao; Marcus T Alley; Payam Massaband; Robert J Herfkens; Frandics P Chan; Shreyas S Vasanawala
Journal:  Pediatr Radiol       Date:  2011-01-11

7.  Rapid pediatric cardiac assessment of flow and ventricular volume with compressed sensing parallel imaging volumetric cine phase-contrast MRI.

Authors:  Albert Hsiao; Michael Lustig; Marcus T Alley; Mark Murphy; Frandics P Chan; Robert J Herfkens; Shreyas S Vasanawala
Journal:  AJR Am J Roentgenol       Date:  2012-03       Impact factor: 3.959

8.  2D free-breathing dual navigator-gated cardiac function validated against the 2D breath-hold acquisition.

Authors:  Dana C Peters; Reza Nezafat; Holger Eggers; Christian Stehning; Warren J Manning
Journal:  J Magn Reson Imaging       Date:  2008-09       Impact factor: 4.813

9.  Venous and arterial flow quantification are equally accurate and precise with parallel imaging compressed sensing 4D phase contrast MRI.

Authors:  Umar Tariq; Albert Hsiao; Marcus Alley; Tao Zhang; Michael Lustig; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2012-11-21       Impact factor: 4.813

10.  Single-Breathhold Four-Dimensional Assessment of Left Ventricular Morphological and Functional Parameters by Magnetic Resonance Imaging Using the VAST Technique.

Authors:  Carlos Eduardo Rochitte; Clerio F Azevedo; Miguel A Rosário; Maria H R Siqueira; Victor Monsão; Manoj Saranathan; Thomas K Foo; Roberto Kalil Filho; Giovanni G Cerri; José A F Ramires
Journal:  Open Cardiovasc Med J       Date:  2011-03-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.