Literature DB >> 14598903

Improved functional cardiac MR imaging using the intravascular contrast agent CLARISCAN.

I Paetsch1, H Thiele, B Schnackenburg, A Bornstedt, A Müller-York, J Schwab, E Fleck, E Nagel.   

Abstract

PURPOSE: Using segmented k-space turbo gradient echo MR techniques (TGE) contrast between blood and myocardium is often reduced in long axis views due to reduced in plane spin-refreshment, particularly in patients with low ejection fraction. The application of an intravascular contrast agent (CA) may improve endocardial border delineation.
MATERIALS AND METHODS: In 15 patients cardiac cine loops in two long axis and two short axis views were acquired during breath hold using a TGE sequence without and with increasing doses of CA (0.75, 2.0, 5.0 mg Fe/kg). Two independent observers evaluated left ventricular function (LVEF, modified Simpson's rule) and assigned a visual score (range: 0 = 'not visualized' to 6 = 'excellent visualization') for endocardial border delineation. Signal- and contrast-to-noise ratios (SNR; CNR) were determined.
RESULTS: Endocardial border delineation score for TGE was 1.7 +/- 0.6 and 3.9 +/- 0.6**, 4.4 +/- 0.5**, 4.6 +/- 0.4** for 0.75, 2.0, 5.0 mg Fe/kg of CA, respectively (**p < 0.01 vs. TGE). SNR of blood increased significantly with any dose of CA with a mild drop of myocardial SNR resulting in a significant increase of CNR blood/myocardium. The maximum effect with 2.0 mg Fe/kg was a >2-fold CNR increase. Inter- and intraobserver variability assessed according to the method of Bland-Altmann was reduced at 2.0 mg Fe/kg for determination of LVEF and reached statistical significance for LVEF <50%.
CONCLUSION: Intravascular CA increased CNR between blood and myocardium by a factor >2 and significantly improved the determination of cardiac volumes. The benefit in accuracy was most for patients with left ventricular ejection fraction <50%.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14598903     DOI: 10.1023/a:1025432415983

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  24 in total

Review 1.  Quantification of global and regional ventricular function in cardiac magnetic resonance imaging.

Authors:  R J van der Geest; B P Lelieveldt; J H Reiber
Journal:  Top Magn Reson Imaging       Date:  2000-12

2.  MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study.

Authors:  J Barkhausen; S G Ruehm; M Goyen; T Buck; G Laub; J F Debatin
Journal:  Radiology       Date:  2001-04       Impact factor: 11.105

3.  Use of an intravascular T1 contrast agent to improve MR cine myocardial-blood pool definition in man.

Authors:  A E Stillman; N Wilke; M Jerosch-Herold
Journal:  J Magn Reson Imaging       Date:  1997 Jul-Aug       Impact factor: 4.813

4.  Ejection fraction determination by MR imaging: comparison with left ventricular angiography.

Authors:  E J Stratemeier; R Thompson; T J Brady; S W Miller; S Saini; G L Wismer; R D Okada; R E Dinsmore
Journal:  Radiology       Date:  1986-03       Impact factor: 11.105

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Automated myocardial edge detection from breath-hold cine-MR images: evaluation of left ventricular volumes and mass.

Authors:  C Baldy; P Douek; P Croisille; I E Magnin; D Revel; M Amiel
Journal:  Magn Reson Imaging       Date:  1994       Impact factor: 2.546

7.  Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance.

Authors:  N G Bellenger; L C Davies; J M Francis; A J Coats; D J Pennell
Journal:  J Cardiovasc Magn Reson       Date:  2000       Impact factor: 5.364

8.  [Influence of image quality on the diagnostic accuracy of dobutamine stress magnetic resonance imaging in comparison with dobutamine stress echocardiography for the noninvasive detection of myocardial ischemia].

Authors:  E Nagel; H B Lehmkuhl; C Klein; U Schneider; E Frantz; A Ellmer; W Bocksch; S Dreysse; E Fleck
Journal:  Z Kardiol       Date:  1999-09

9.  Noninvasive diagnosis of ischemia-induced wall motion abnormalities with the use of high-dose dobutamine stress MRI: comparison with dobutamine stress echocardiography.

Authors:  E Nagel; H B Lehmkuhl; W Bocksch; C Klein; U Vogel; E Frantz; A Ellmer; S Dreysse; E Fleck
Journal:  Circulation       Date:  1999-02-16       Impact factor: 29.690

10.  Improved cine MR imaging of left ventricular wall motion with gadopentetate dimeglumine.

Authors:  D J Pennell; S R Underwood; D B Longmore
Journal:  J Magn Reson Imaging       Date:  1993 Jan-Feb       Impact factor: 4.813

View more
  1 in total

1.  Measurement of left ventricular dimensions with contrast-enhanced three-dimensional cine imaging facilitated by k-t SENSE.

Authors:  Neil Maredia; Sebastian Kozerke; Abdul Larghat; Nik Abidin; John P Greenwood; Peter Boesiger; Sven Plein
Journal:  J Cardiovasc Magn Reson       Date:  2008-05-28       Impact factor: 5.364

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.