Literature DB >> 10082058

Comparison of letter and Vernier acuities with dioptric and diffusive blur.

H E Bedell1, S Patel, S T Chung.   

Abstract

We assessed the influence of dioptric and diffusive blur on normal subjects' letter and Vernier acuity in two experiments. In the first experiment, letter acuity was measured for isolated black Sloan letters and Vernier acuity was determined for a pair of black vertical abutting or nonabutting lines. Targets were viewed through plus lenses that produced 0, 1, 2, 4, and 8 D of dioptric blur. In the second experiment, letter acuity was determined for bright 4-position Ts and Vernier acuity was measured for a pair of bright abutting vertical lines. Six levels of imposed diffusive blur were produced by varying the distance between a ground glass screen and the oscilloscope on which the targets were presented. The results of both experiments indicate that letter and Vernier acuity for abutting or closely separated lines worsen in parallel curvilinear fashion, as long as the lines comprising the Vernier targets remain equally detectable when various amounts of dioptric and diffusive blur are imposed. We conclude that both dioptric and diffusive blur introduce common processing limitations for letter and Vernier acuity.

Mesh:

Year:  1999        PMID: 10082058     DOI: 10.1097/00006324-199902000-00019

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  5 in total

1.  The effect of dioptric blur on reading performance.

Authors:  Susana T L Chung; Samuel H Jarvis; Sing-Hang Cheung
Journal:  Vision Res       Date:  2007-04-17       Impact factor: 1.886

2.  Change in visual acuity is highly correlated with change in six image quality metrics independent of wavefront error and/or pupil diameter.

Authors:  Ayeswarya Ravikumar; Edwin J Sarver; Raymond A Applegate
Journal:  J Vis       Date:  2012-09-14       Impact factor: 2.240

3.  Visual deficits in anisometropia.

Authors:  Dennis M Levi; Suzanne P McKee; J Anthony Movshon
Journal:  Vision Res       Date:  2010-10-07       Impact factor: 1.886

4.  Understanding the Impact of Individual Perceived Image Quality Features on Visual Performance.

Authors:  Julia S Benoit; Ayeswarya Ravikumar; Jason D Marsack; Heather A Anderson
Journal:  Transl Vis Sci Technol       Date:  2020-04-15       Impact factor: 3.283

5.  Habitual higher order aberrations affect Landolt but not Vernier acuity.

Authors:  Jenny L Reiniger; Anne C Lobecke; Ramkumar Sabesan; Michael Bach; Frenne Verbakel; John de Brabander; Frank G Holz; Tos T J M Berendschot; Wolf M Harmening
Journal:  J Vis       Date:  2019-05-01       Impact factor: 2.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.