Literature DB >> 20821093

Comparison of detectability of a simple object with low contrast displayed on a high-brightness color LCD and a monochrome LCD.

Keita Takahashi1, Junji Morishita, Takeshi Hiwasa, Shiro Hatanaka, Shuji Sakai, Noriyuki Hashimoto, Yasuhiko Nakamura, Fukai Toyofuku, Yoshiharu Higashida, Masafumi Ohki.   

Abstract

The goal of this study was to investigate the effect of the different luminance settings of a high-brightness color liquid-crystal display (LCD) on the detectability of a simple grayscale object with low contrast by use of receiver operating characteristic (ROC) analysis. The detectability of a high-brightness color LCD with two maximum-luminance settings (500 and 170 cd/m(2)) was compared with the detectability of a monochrome LCD (500 cd/m(2)). The two LCDs used in this study were calibrated to the grayscale standard display function. The average areas under the ROC curve (AUCs) and the standard deviations for all thirteen observers for the 500 cd/m(2) color LCD, 500 cd/m(2) monochrome LCD, and 170 cd/m(2) color LCD were 0.937 +/- 0.040, 0.924 +/- 0.056, and 0.915 +/- 0.068, respectively. There were no statistically significant differences in the average AUCs among the three LCD monitor conditions. On the other hand, the total observation time for the 170 cd/m(2) color LCD was significantly shorter than that for the 500 cd/m(2) color and monochrome LCDs (p < 0.05). Irrespective of the maximum luminance settings (500 and 170 cd/m(2)), the color LCD provided a performance comparable to the monochrome LCD for detection of a simple grayscale object with low contrast.

Entities:  

Mesh:

Year:  2010        PMID: 20821093     DOI: 10.1007/s12194-010-0095-9

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  18 in total

1.  Effects of luminance and resolution on observer performance with chest radiographs.

Authors:  J M Herron; T M Bender; W L Campbell; J H Sumkin; H E Rockette; D Gur
Journal:  Radiology       Date:  2000-04       Impact factor: 11.105

2.  "Proper" Binormal ROC Curves: Theory and Maximum-Likelihood Estimation.

Authors: 
Journal:  J Math Psychol       Date:  1999-03       Impact factor: 2.223

Review 3.  [Image display devices (1)].

Authors:  Noriyuki Hashimoto
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2002-10

4.  Effect of monitor luminance and ambient light on observer performance in soft-copy reading of digital chest radiographs.

Authors:  Jin Mo Goo; Ja-Young Choi; Jung-Gi Im; Hyun Ju Lee; Myung Jin Chung; Daehee Han; Seong Ho Park; Jong Hyo Kim; Sang-Hee Nam
Journal:  Radiology       Date:  2004-07-23       Impact factor: 11.105

5.  Effect of test patterns on measurement of the luminance of LCD devices by use of a telescopic-type luminance meter.

Authors:  Junji Morishita; Kiyoshi Dogomori; Shiro Hatanaka; Takeshi Hiwasa; Yasuhiko Nakamura; Noriyuki Hashimoto; Yoshiharu Higashida; Fukai Toyofuku; Masafumi Ohki
Journal:  Radiol Phys Technol       Date:  2007-11-28

6.  Detectability of a lung nodule displayed on a liquid-crystal display monitor with different maximum luminance settings.

Authors:  Keita Takahashi; Masaki Sueoka; Yongsu Yoon; Takeshi Hiwasa; Shiro Hatanaka; Yasuhiko Nakamura; Noriyuki Hashimoto; Masafumi Ohki; Junji Morishita
Journal:  Radiol Phys Technol       Date:  2009-09-01

7.  [Comparison of LCD and CRT monitors for detection of pulmonary nodules and interstitial lung diseases on digital chest radiographs by using receiver operating characteristic analysis].

Authors:  Ryuji Ikeda; Shigehiko Katsuragawa; Toshiaki Shimonobou; Yasuhiro Hiai; Masahiro Hashida; Kazuo Awai; Yasuyuki Yamashita; Kunio Doi
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2006-05-20

8.  Digital mammography: comparative performance of color LCD and monochrome CRT displays.

Authors:  Ehsan Samei; Ananth Poolla; Michael J Ulissey; John M Lewin
Journal:  Acad Radiol       Date:  2007-05       Impact factor: 3.173

9.  The effect of intensity windowing on the detection of simulated masses embedded in dense portions of digitized mammograms in a laboratory setting.

Authors:  E D Pisano; J Chandramouli; B M Hemminger; D Glueck; R E Johnston; K Muller; M P Braeuning; D Puff; W Garrett; S Pizer
Journal:  J Digit Imaging       Date:  1997-11       Impact factor: 4.056

10.  Reliable and computationally efficient maximum-likelihood estimation of "proper" binormal ROC curves.

Authors:  Lorenzo L Pesce; Charles E Metz
Journal:  Acad Radiol       Date:  2007-07       Impact factor: 3.173

View more
  1 in total

1.  Technical and radiological image quality comparison of different liquid crystal displays for radiology.

Authors:  Francina Em Dams; K Y Esther Leung; Pieter Hm van der Valk; Marc Cjm Kock; Jeroen Bosman; Sjoerd P Niehof
Journal:  Med Devices (Auckl)       Date:  2014-10-31
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.