Literature DB >> 10037065

Summary of results using the nucleus CI24M implant to record the electrically evoked compound action potential.

P J Abbas1, C J Brown, J K Shallop, J B Firszt, M L Hughes, S H Hong, S J Staller.   

Abstract

OBJECTIVE: This study outlines a series of experiments using the neural response telemetry (NRT) system of the Nucleus CI24M cochlear implant to measure the electrically evoked compound action potential (EAP). The goal of this investigation was to develop a protocol that allows successful recording of the EAP in a majority of CI24M cochlear implant users.
DESIGN: Twenty-six postlingually deafened adults participated in this study. A series of experiments were conducted that allowed us to examine how manipulation of stimulation and recording parameters may affect the morphology of the EAP recorded using the Nucleus NRT system.
RESULTS: Results of this study show consistent responses on at least some electrodes from all subjects. Cross-subject and cross electrode variations in both the growth of the response and the temporal refractory properties of the response were observed. The range of stimulus and recording parameters that can be used to record the EAP with the Nucleus NRT system is described.
CONCLUSIONS: Using the protocol outlined in this study, it is possible to reliably record EAP responses from most subjects and for most electrodes in Nucleus CI24M cochlear implant users. These responses are robust and recording these responses does not require that the subject sleep or remain still. Based on these results, a specific protocol is proposed for measurement of the EAP using the NRT system of the CI24M cochlear implant. Potential clinical implications of these results are discussed.

Mesh:

Year:  1999        PMID: 10037065     DOI: 10.1097/00003446-199902000-00005

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.570


  69 in total

1.  Intra-Operative Neural Response Telemetry and Acoustic Reflex Assessment using an Advance-In-Stylet Technique and Modiolus-Hugging: A prospective cohort study.

Authors:  Abdulrahman Hagr
Journal:  Sultan Qaboos Univ Med J       Date:  2011-08-15

2.  Effect of stimulus and recording parameters on spatial spread of excitation and masking patterns obtained with the electrically evoked compound action potential in cochlear implants.

Authors:  Michelle L Hughes; Lisa J Stille
Journal:  Ear Hear       Date:  2010-10       Impact factor: 3.570

3.  Excitation Patterns of Standard and Steered Partial Tripolar Stimuli in Cochlear Implants.

Authors:  Ching-Chih Wu; Xin Luo
Journal:  J Assoc Res Otolaryngol       Date:  2015-12-21

4.  Effect of stimulus level on the temporal response properties of the auditory nerve in cochlear implants.

Authors:  Michelle L Hughes; Sarah A Laurello
Journal:  Hear Res       Date:  2017-06-13       Impact factor: 3.208

5.  Electrically evoked compound action potential measures for virtual channels versus physical electrodes.

Authors:  Michelle L Hughes; Adam M Goulson
Journal:  Ear Hear       Date:  2011 May-Jun       Impact factor: 3.570

6.  Psychophysical and physiological measures of electrical-field interaction in cochlear implants.

Authors:  Michelle L Hughes; Lisa J Stille
Journal:  J Acoust Soc Am       Date:  2009-01       Impact factor: 1.840

7.  ECAP spread of excitation with virtual channels and physical electrodes.

Authors:  Michelle L Hughes; Lisa J Stille; Jacquelyn L Baudhuin; Jenny L Goehring
Journal:  Hear Res       Date:  2013-10-03       Impact factor: 3.208

8.  Across-site patterns of electrically evoked compound action potential amplitude-growth functions in multichannel cochlear implant recipients and the effects of the interphase gap.

Authors:  Kara C Schvartz-Leyzac; Bryan E Pfingst
Journal:  Hear Res       Date:  2016-08-10       Impact factor: 3.208

9.  Comparison of electrically evoked compound action potential thresholds and loudness estimates for the stimuli used to program the Advanced Bionics cochlear implant.

Authors:  Eun Kyung Jeon; Carolyn J Brown; Christine P Etler; Sara O'Brien; Li-Kuei Chiou; Paul J Abbas
Journal:  J Am Acad Audiol       Date:  2010-01       Impact factor: 1.664

10.  Effects of long-term use of a cochlear implant on the electrically evoked compound action potential.

Authors:  Carolyn J Brown; Paul J Abbas; Christine P Etlert; Sara O'Brient; Jacob J Oleson
Journal:  J Am Acad Audiol       Date:  2010-01       Impact factor: 1.664

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.