Why and how is soft copy reading possible in clinical practice?

T Mertelmeier1.   

Abstract

The properties of the human visual system (HVS) relevant to the diagnostic process are described after a brief introduction on the general problems and advantages of using soft copy for primary radiology interpretations. At various spatial and temporal frequencies the contrast sensitivity defines the spatial resolution of the eye-brain system and the sensitivity to flicker. The adaptation to the displayed radiological scene and the ambient illumination determine the dynamic range for the operation of the HVS. Although image display devices are determined mainly by state-of-the-art technology, analysis of the HVS may suggest technical characteristics for electronic displays that will help to optimize the display to the operation of the HVS. These include display size, spatial resolution, contrast resolution, luminance range, and noise, from which further consequences for the technical components of a monitor follow. It is emphasized that routine monitor quality control must be available in clinical practice. These image quality measures must be simple enough to be applied as part of the daily routine. These test instructions might also serve as elements of technical acceptance and constancy tests.

Entities:  

Mesh:

Year:  1999        PMID: 10036662      PMCID: PMC3452431          DOI: 10.1007/bf03168621

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  10 in total

1.  Light distribution in the image formed by the living human eye.

Authors:  G WESTHEIMER; F W CAMPBELL
Journal:  J Opt Soc Am       Date:  1962-09

2.  Filmless radiology: how the Baltimore VA does it.

Authors:  E Siegel
Journal:  Diagn Imaging (San Franc)       Date:  1997-06

Review 3.  Human visual perception and ROC methodology in medical imaging.

Authors:  M S Chesters
Journal:  Phys Med Biol       Date:  1992-07       Impact factor: 3.609

4.  Contrast thresholds of the human eye.

Authors:  H R BLACKWELL
Journal:  J Opt Soc Am       Date:  1946-11

5.  Receiver operating characteristic study of image preprocessing for teleradiology and digital workstations.

Authors:  S R Bolle; T Sund; J Størmer
Journal:  J Digit Imaging       Date:  1997-11       Impact factor: 4.056

6.  The effects of background illumination on the photoresponses of red and green cones.

Authors:  R A Normann; I Perlman
Journal:  J Physiol       Date:  1979-01       Impact factor: 5.182

7.  Test pattern for video displays and hard-copy cameras.

Authors:  J E Gray; K G Lisk; D H Haddick; J H Harshbarger; A Oosterhof; R Schwenker
Journal:  Radiology       Date:  1985-02       Impact factor: 11.105

8.  High-resolution computer display of portable, digital, chest radiographs of adults: suitability for primary interpretation.

Authors:  M S Frank; R G Jost; P L Molina; D J Anderson; S L Solomon; R A Whitman; S M Moore
Journal:  AJR Am J Roentgenol       Date:  1993-03       Impact factor: 3.959

9.  Changes in lesion detectability caused by light adaptation in retinal photoreceptors.

Authors:  B Baxter; H Ravindra; R A Normann
Journal:  Invest Radiol       Date:  1982 Jul-Aug       Impact factor: 6.016

10.  Brightness perception in complex fields.

Authors:  C J Bartleson; E J Breneman
Journal:  J Opt Soc Am       Date:  1967-07
  10 in total
  4 in total

1.  Effect of room illuminance on monitor black level luminance and monitor calibration.

Authors:  K Chakrabarti; R V Kaczmarek; J A Thomas; A Romanyukha
Journal:  J Digit Imaging       Date:  2004-01-30       Impact factor: 4.056

2.  Diagnostic performance of liquid crystal and cathode-ray-tube monitors in brain computed tomography.

Authors:  Gerald Pärtan; Rudolf Mayrhofer; Michael Urban; Manfred Wassipaul; Ludwig Pichler; Walter Hruby
Journal:  Eur Radiol       Date:  2003-02-19       Impact factor: 5.315

3.  [The quality of digital mammograms. Development and use of phantoms for optimal safety].

Authors:  H Schöfer; D Kotsianos; S Wirth; S Britsch; M Reiser
Journal:  Radiologe       Date:  2005-03       Impact factor: 0.635

4.  Is targeted reconstruction necessary for evaluating contrast-enhanced chest computed tomography using a liquid crystal display monitor?

Authors:  Yoshiyuki Ozawa; Masaki Hara; Hidekazu Oshima; Masanori Kitase; Kazuya Ohashi; Yuta Shibamoto
Journal:  Radiat Med       Date:  2008-10-31
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.