Abstract

The assessment of cardiac function, particularly cardiac output (Q) during heavy exercise is essential for the evaluation of cardiovascular factors that might limit oxygen transport. A series of invasive and noninvasive techniques has been developed for the assessment and monitoring of Q during resting and submaximal exercise conditions. However, very few techniques have been found to give accurate and reliable determinations of Q during vigorous to maximum exercise. For exercise physiologists and sport cardiologists, maximal exercise data are of primary importance. The 'gold standard' measures of cardiac function are considered to be the direct Fick and dye-dilution methods. These have been widely shown to give accurate and reliable determinations of Q during resting and submaximal exercise conditions; however, their use during maximal exercise conditions is debatable due to the inherent risks involved with each and their increasing inaccuracy during the later stages of vigorous exercise. Thermodilution has also been considered to be a relatively good method for the determination of Q during rest and exercise conditions, but recent authors have questioned its use due to the nature of the measure and its inaccuracy during strenuous exercise. Various noninvasive measures of cardiac function have been developed to overcome the problems associated with the 'gold standard' measures. The first part of this article discusses conventional techniques used in exercise physiology settings. The majority of these provide accurate and reliable determinations of Q during rest and submaximal exercise. However, very few techniques are suitable for maximal exercise conditions. Perhaps only the foreign gas rebreathe using acetylene (C2H2) meets all the criteria of being noninvasive, simple to use, reliable over repeated measurements, accurate and useful during maximal exercise.

Entities:  

Mesh:

Year:  1999        PMID: 10028131     DOI: 10.2165/00007256-199927010-00003

Source DB:  PubMed          Journal:  Sports Med        ISSN: 0112-1642            Impact factor:   11.136


  94 in total

1.  CIRCULATORY RESPONSE TO PROLONGED SEVERE EXERCISE.

Authors:  B SALTIN; J STENBERG
Journal:  J Appl Physiol       Date:  1964-09       Impact factor: 3.531

2.  Cardiac output in normal subjects under standard basal conditions; the repeatability of measurements by the Fick method.

Authors:  B THOMASSON
Journal:  Scand J Clin Lab Invest       Date:  1957       Impact factor: 1.713

3.  Simultaneous determinations of the resting arteriovenous oxygen difference by the acetylene and direct Fick methods.

Authors:  C B CHAPMAN; H L TAYLOR; C BORDEN; R V EBERT; A KEYS
Journal:  J Clin Invest       Date:  1950-06       Impact factor: 14.808

4.  Determinants of variation between Fick and indicator dilution estimates of cardiac output during diagnostic catheterization. Fick vs. dye cardiac outputs.

Authors:  P S Reddy; E I Curtiss; B Bell; J D O'Toole; R Salerni; D F Leon; J A Shaver
Journal:  J Lab Clin Med       Date:  1976-04

5.  Cardiac output in middle-aged patients determined with CO2 rebreathing method.

Authors:  J P Clausen; O A Larsen; J Trap-Jensen
Journal:  J Appl Physiol       Date:  1970-03       Impact factor: 3.531

6.  Evaluation using dogs of a method for estimating mixed venous and arterial PCO2 from a single breath.

Authors:  M M Mohammed; R Hainsworth
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1981-01

7.  Cardiac output measured by acetylene rebreathing technique at rest and during exercise. Comparison of results obtained by various calculation procedures.

Authors:  I L Kanstrup; I Hallbäck
Journal:  Pflugers Arch       Date:  1981-05       Impact factor: 3.657

8.  Differences in cardiovascular adaptations to endurance exercise training between older men and women.

Authors:  R J Spina; T Ogawa; W M Kohrt; W H Martin; J O Holloszy; A A Ehsani
Journal:  J Appl Physiol (1985)       Date:  1993-08

9.  Exercise stroke volume relative to plasma-volume expansion.

Authors:  M K Hopper; A R Coggan; E F Coyle
Journal:  J Appl Physiol (1985)       Date:  1988-01

10.  Comparison of cardiac output measurement techniques: thermodilution, Doppler, CO2-rebreathing and the direct Fick method.

Authors:  K Espersen; E W Jensen; D Rosenborg; J K Thomsen; K Eliasen; N V Olsen; I L Kanstrup
Journal:  Acta Anaesthesiol Scand       Date:  1995-02       Impact factor: 2.105

View more
  21 in total

Review 1.  Doppler echocardiography for the estimation of cardiac output with exercise.

Authors:  Thomas Rowland; Philippe Obert
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

2.  Calculating alveolar capillary conductance and pulmonary capillary blood volume: comparing the multiple- and single-inspired oxygen tension methods.

Authors:  Maile L Ceridon; Kenneth C Beck; Thomas P Olson; Jordan A Bilezikian; Bruce D Johnson
Journal:  J Appl Physiol (1985)       Date:  2010-06-10

3.  Cardiac output and oxygen release during very high-intensity exercise performed until exhaustion.

Authors:  Ruddy Richard; Evelyne Lonsdorfer-Wolf; Stéphane Dufour; Stéphane Doutreleau; Monique Oswald-Mammosser; Véronique L Billat; Jean Lonsdorfer
Journal:  Eur J Appl Physiol       Date:  2004-07-27       Impact factor: 3.078

4.  Application of bioreactance for cardiac output assessment during exercise in healthy individuals.

Authors:  Adrian Elliott; James H Hull; David Nunan; Djordje G Jakovljevic; David Brodie; Lesley Ansley
Journal:  Eur J Appl Physiol       Date:  2010-03-25       Impact factor: 3.078

5.  The role of muscle pump in the development of cardiovascular drift.

Authors:  Stylianos N Kounalakis; Michail E Keramidas; George P Nassis; Nickos D Geladas
Journal:  Eur J Appl Physiol       Date:  2008-01-05       Impact factor: 3.078

6.  Cardiovascular effects of anti-G suit inflation at 1 and 2 G.

Authors:  Stéphanie Montmerle; Dag Linnarsson
Journal:  Eur J Appl Physiol       Date:  2005-04-07       Impact factor: 3.078

7.  Autonomic and cardiovascular function in HIV spectrum disease: early indications of cardiac pathophysiology.

Authors:  K A Brownley; J R Milanovich; S J Motivala; N Schneiderman; L Fillion; J A Graves; N G Klimas; M A Fletcher; B E Hurwitz
Journal:  Clin Auton Res       Date:  2001-10       Impact factor: 4.435

8.  Mean Blood Pressure Assessment during Post-Exercise: Result from Two Different Methods of Calculation.

Authors:  Gianmarco Sainas; Raffaele Milia; Girolamo Palazzolo; Gianfranco Ibba; Elisabetta Marongiu; Silvana Roberto; Virginia Pinna; Giovanna Ghiani; Filippo Tocco; Antonio Crisafulli
Journal:  J Sports Sci Med       Date:  2016-08-05       Impact factor: 2.988

9.  Cardiac output with modified cardio-impedance against inert gas rebreathing during sub-maximal and maximal cycling exercise in healthy and fit subjects.

Authors:  Alessio Del Torto; Øyvind Skattebo; Jostein Hallén; Carlo Capelli
Journal:  Eur J Appl Physiol       Date:  2018-10-17       Impact factor: 3.078

Review 10.  Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part II: Novel techniques and new advances.

Authors:  D E Warburton; M J Haykowsky; H A Quinney; D P Humen; K K Teo
Journal:  Sports Med       Date:  1999-04       Impact factor: 11.136

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.