Comparison of cardiac output measurement techniques: thermodilution, Doppler, CO2-rebreathing and the direct Fick method.

K Espersen1, E W Jensen, D Rosenborg, J K Thomsen, K Eliasen, N V Olsen, I L Kanstrup.   

Abstract

Simultaneously measured cardiac output obtained by thermodilution (TD), transcutaneous suprasternal ultrasonic Doppler (DOP), CO2-rebreathing (CR) and the direct Fick method (FI) were compared in eleven healthy subjects in a supine position (SU), a sitting position (SI), and during sitting exercise at a workload of 50 W (EX). The agreements between the techniques, two by two, were expressed as the bias calculated as the averaged differences between the techniques. Precision was expressed as the standard deviation of the bias. The overall agreement (bias +/- precision) between TD, DOP and CR respectively and FI were 2.3 +/- 1.6, -0.1 +/- 1.4, and -0.2 +/- 1.1 l/min. TD overestimated cardiac output consistently in SU, SI and EX. DOP was in-accurate during EX and agreed well with FI in SU and SI. CR agreed closely with FI in SI and EX, but values were underestimated in SU. The overall agreement between DOP and CR, respectively, and TD were 2.5 +/- 2.2 and 2.6 +/- 1.6 l/min. The overall agreement between DOP and CR was 0.1 +/- 1.6 l/min. In conclusion, TD overestimated cardiac output compared to the other techniques and the poor agreement has to be taken into consideration especially in measures of low values. The precision of DOP and CR against FI seems to be within clinically acceptable limits, and these methods may provide interchangeable alternatives to the invasive Fick method.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7793193     DOI: 10.1111/j.1399-6576.1995.tb04051.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  24 in total

Review 1.  Doppler echocardiography for the estimation of cardiac output with exercise.

Authors:  Thomas Rowland; Philippe Obert
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

2.  A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques.

Authors:  L A Critchley; J A Critchley
Journal:  J Clin Monit Comput       Date:  1999-02       Impact factor: 2.502

3.  Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis.

Authors:  Sebastiaan A Bartels; Wim J Stok; Rick Bezemer; Remco J Boksem; Jeroen van Goudoever; Thomas G V Cherpanath; Johannes J van Lieshout; Berend E Westerhof; John M Karemaker; Can Ince
Journal:  J Clin Monit Comput       Date:  2011-10-15       Impact factor: 2.502

Review 4.  [Measurement of cardiac output].

Authors:  D A Reuter; A E Goetz
Journal:  Anaesthesist       Date:  2005-11       Impact factor: 1.041

5.  Magnetic resonance imaging guided catheterisation for assessment of pulmonary vascular resistance: in vivo validation and clinical application in patients with pulmonary hypertension.

Authors:  T Kuehne; S Yilmaz; I Schulze-Neick; E Wellnhofer; P Ewert; E Nagel; P Lange
Journal:  Heart       Date:  2005-08       Impact factor: 5.994

6.  Mitochondrial coupling in humans: assessment of the P/O2 ratio at the onset of calf exercise.

Authors:  V Cettolo; M Cautero; E Tam; M P Francescato
Journal:  Eur J Appl Physiol       Date:  2007-01-06       Impact factor: 3.078

Review 7.  Cardiac output in 1998.

Authors:  M Singer
Journal:  Heart       Date:  1998-05       Impact factor: 5.994

8.  Reproducibility of the exponential rise technique of CO(2) rebreathing for measuring P(v)CO(2) and C(v)CO(2 )to non-invasively estimate cardiac output during incremental, maximal treadmill exercise.

Authors:  W Todd Cade; Sharmila R Nabar; Randall E Keyser
Journal:  Eur J Appl Physiol       Date:  2003-12-03       Impact factor: 3.078

9.  Cardiac response to exercise in young, normal weight and overweight men and women.

Authors:  Chantal A Vella; Raul Y Zubia; Stephen F Burns; Diana Ontiveros
Journal:  Eur J Appl Physiol       Date:  2008-11-07       Impact factor: 3.078

10.  Beat-to-beat noninvasive stroke volume from arterial pressure and Doppler ultrasound.

Authors:  Johannes J van Lieshout; Karin Toska; Erik Jan van Lieshout; Morten Eriksen; Lars Walløe; Karel H Wesseling
Journal:  Eur J Appl Physiol       Date:  2003-07-08       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.