Determinants of variation between Fick and indicator dilution estimates of cardiac output during diagnostic catheterization. Fick vs. dye cardiac outputs.

P S Reddy, E I Curtiss, B Bell, J D O'Toole, R Salerni, D F Leon, J A Shaver.   

Abstract

Simultaneous Fick and duplicate dye cardiac outputs were done in 105 patients with various cardiovascular diseases during routine cardiac catheterization. Dye was injected into the pulmonary artery and sampled from the brachial artery. Nineteen patients had mitral and/or aortic valvular regurgitation. Eighty-four per cent of the duplicate dye cardiac outputs agreed within 10 per cent variation from the line of identity, and 98 per cent were within 25 per cent. There was no systematic difference between the Fick and dye methods. Seventy-five per cent agree within 20 per cent variation from the line of identity. However, individual variation ranged from -27 to +58 per cent. There was, also, no systematic difference between Fick and dye methods either with low cardiac index or valvular regurgitation. Variation between the two methods was less with low cardiac index and greater with higher cardiac index. The variation was not increased in the presence of valvular regurgitation. The variation in the two methods could partly be explained by errors in the measurement of arteriovenous oxygen difference and oxygen consumption. When the injection is made into the pulmonary artery and sampled from the brachial artery, dye outputs are valid irrespective of the level of resting cardiac index and valvular regurgitation as long as there are enough points to draw a straight line from semilogarithmic trace of the descending limb.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 775003

Source DB:  PubMed          Journal:  J Lab Clin Med        ISSN: 0022-2143


  5 in total

Review 1.  Doppler echocardiography for the estimation of cardiac output with exercise.

Authors:  Thomas Rowland; Philippe Obert
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

2.  Automated non-invasive measurement of cardiac output by the carbon dioxide rebreathing method: comparisons with dye dilution and thermodilution.

Authors:  A E Russell; S A Smith; M J West; P E Aylward; R J McRitchie; R M Hassam; R B Minson; L M Wing; J P Chalmers
Journal:  Br Heart J       Date:  1990-03

3.  Evaluation of haemodynamics by cardiac catheterisation: historical perspective and present practice.

Authors:  A Bergstra; A F M van den Heuvel; G A Mook; F Zijlstra
Journal:  Neth Heart J       Date:  2005-04       Impact factor: 2.380

4.  Method of assessing the reproducibility of blood flow measurement: factors influencing the performance of thermodilution cardiac output computers.

Authors:  J D Mackenzie; N E Haites; J M Rawles
Journal:  Br Heart J       Date:  1986-01

Review 5.  Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part I: Conventional techniques.

Authors:  D E Warburton; M J Haykowsky; H A Quinney; D P Humen; K K Teo
Journal:  Sports Med       Date:  1999-01       Impact factor: 11.136