Literature DB >> 10027124

Can implantable defibrillators reduce non-arrhythmic mortality?

S Nisam1.   

Abstract

Several authors have made the intriguing observation that Implantable Cardioverter Defibrillators (ICD) appear not only to reduce sudden deaths, but also mortality due to non-arrhythmic causes. Studies have shown that this observation can not be attributed to patient selection bias. In trying to explain this apparent anomaly, it should be noted that two treatment strategies are being compared. Thus, it might be that, under certain circumstances, antiarrhythmic drugs contribute to non-arrhythmic deaths, not that ICDs reduce them. There appear to be some plausible explanations for this phenomenon, e.g., the long-term effect on cardiac function of episodes of ventricular tachycardia lasting for several hours for patients treated solely by antiarrhythmic drugs, compared to their quick termination by an ICD. However, further research into this curious mode of death issue is needed, and may provide further insights into patient populations deriving greatest benefit from one therapy or the other.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 10027124     DOI: 10.1023/a:1009720906851

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  18 in total

Review 1.  Clinical strategies for use of the implantable cardioverter defibrillator: the impact of current trials.

Authors:  N A Estes
Journal:  Pacing Clin Electrophysiol       Date:  1996-07       Impact factor: 1.976

2.  Implantation of a cardioverter/defibrillator without thoracotomy using a triple electrode system.

Authors:  S Saksena; V Parsonnet
Journal:  JAMA       Date:  1988-01-01       Impact factor: 56.272

3.  Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators.

Authors:  A J Moss; W J Hall; D S Cannom; J P Daubert; S L Higgins; H Klein; J H Levine; S Saksena; A L Waldo; D Wilber; M W Brown; M Heo
Journal:  N Engl J Med       Date:  1996-12-26       Impact factor: 91.245

Review 4.  Mortality benefits and the implantable cardioverter-defibrillator.

Authors:  M O Sweeney; J N Ruskin
Journal:  Circulation       Date:  1994-04       Impact factor: 29.690

5.  Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings.

Authors:  M Mirowski; P R Reid; M M Mower; L Watkins; V L Gott; J F Schauble; A Langer; M S Heilman; S A Kolenik; R E Fischell; M L Weisfeldt
Journal:  N Engl J Med       Date:  1980-08-07       Impact factor: 91.245

6.  Survival after implantation of the cardioverter defibrillator.

Authors:  D Newman; M J Sauve; J Herre; J J Langberg; M A Lee; C Titus; J Franklin; M M Scheinman; J C Griffin
Journal:  Am J Cardiol       Date:  1992-04-01       Impact factor: 2.778

7.  Preliminary report: effect of encainide and flecainide on mortality in a randomized trial of arrhythmia suppression after myocardial infarction.

Authors: 
Journal:  N Engl J Med       Date:  1989-08-10       Impact factor: 91.245

8.  A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias.

Authors: 
Journal:  N Engl J Med       Date:  1997-11-27       Impact factor: 91.245

9.  Long-term outcome with the automatic implantable cardioverter-defibrillator.

Authors:  R A Winkle; R H Mead; M A Ruder; V A Gaudiani; N A Smith; W S Buch; P Schmidt; T Shipman
Journal:  J Am Coll Cardiol       Date:  1989-05       Impact factor: 24.094

10.  Randomized study of implantable defibrillator as first-choice therapy versus conventional strategy in postinfarct sudden death survivors.

Authors:  E F Wever; R N Hauer; F L van Capelle; J G Tijssen; H J Crijns; A Algra; A C Wiesfeld; P F Bakker; E O Robles de Medina
Journal:  Circulation       Date:  1995-04-15       Impact factor: 29.690

View more
  1 in total

Review 1.  Perspectives: does amiodarone increase non-sudden deaths? If so, why?

Authors:  A Auricchio; S Nisam; H U Klein
Journal:  J Interv Card Electrophysiol       Date:  2000-12       Impact factor: 1.900