Long-term outcome with the automatic implantable cardioverter-defibrillator.

R A Winkle1, R H Mead, M A Ruder, V A Gaudiani, N A Smith, W S Buch, P Schmidt, T Shipman.   

Abstract

The automatic implantable cardioverter-defibrillator was implanted in 270 patients because of life-threatening arrhythmias over a 7 year period. There was a history of sustained ventricular tachycardia or fibrillation, or both, in 96% of these patients, 80% had one or more prior cardiac arrests and 78% had coronary artery disease as their underlying diagnosis. The average ejection fraction was 34%, and 96% of these patients had had an average of 3.4 antiarrhythmic drug failures per patient before defibrillator implantation. There were four perioperative deaths and eight patients had generator infection or generator erosion, or both, during the perioperative period or during long-term follow-up. Concomitant antiarrhythmic drug therapy was given to 69% of patients. Shocks from the device were given to 58% of patients. and 20% received "problematic" shocks. The device was removed from 16 patients during long-term follow-up for a variety of reasons. There were 7 sudden cardiac deaths and 30 nonsudden cardiac deaths, 18 of which were secondary to congestive heart failure. The actuarial incidence of sudden death, total cardiac death and total mortality from all causes was 1%, 7% and 8%, respectively, at 1 year, and 4%, 24% and 26% at 5 years. The automatic implantable cardioverter-defibrillator nearly eliminates sudden death over a long-term follow-up period in a high risk group of patients. It has an acceptable rate of complications or problems, or both, and most late deaths in these patients are nonsudden and of cardiovascular origin.

Entities:  

Mesh:

Year:  1989        PMID: 2703616     DOI: 10.1016/0735-1097(89)90310-0

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  52 in total

Review 1.  Secondary prevention of sudden death.

Authors:  R Cappato; K H Kuck
Journal:  J Interv Card Electrophysiol       Date:  2000-01       Impact factor: 1.900

Review 2.  Changing concepts of electrophysiology testing for ventricular arrhythmias.

Authors:  M Akhtar
Journal:  J Interv Card Electrophysiol       Date:  2000-01       Impact factor: 1.900

3.  Sudden Electrical Death.

Authors: 
Journal:  Curr Treat Options Cardiovasc Med       Date:  1999-06

Review 4.  Diagnosis and management of ventricular tachycardia.

Authors:  M Dancy
Journal:  Postgrad Med J       Date:  1992-06       Impact factor: 2.401

5.  Life at a price: the implantable defibrillator.

Authors:  R W Campbell
Journal:  Br Heart J       Date:  1990-09

Review 6.  Antiarrhythmic therapies for the prevention of sudden cardiac death.

Authors:  F A McAlister; K K Teo
Journal:  Drugs       Date:  1997-08       Impact factor: 9.546

Review 7.  Combining antiarrhythmic drugs and implantable devices therapy: benefits and outcome.

Authors:  M Santini; C Pandozi; R Ricci
Journal:  J Interv Card Electrophysiol       Date:  2000-01       Impact factor: 1.900

8.  Sudden cardiac death unresponsive to implantable defibrillator therapy: an urgent target for clinicians, industry and government.

Authors:  Kelley P Anderson
Journal:  J Interv Card Electrophysiol       Date:  2005-11       Impact factor: 1.900

9.  Clinical experience with the transvenous Medtronic Pacer Cardioverter Defibrillator (PCD) System.

Authors:  A Golino; C Pappone; A Panza; M Santomauro; D Iorio; V De Amicis; M Chiariello; N Spampinato
Journal:  Tex Heart Inst J       Date:  1993

10.  Efficacy of a tiered therapy defibrillator system used to treat recurrent ventricular arrhythmias refractory to drugs.

Authors:  A C Rankin; S Zaim; A Powell; B Zaim; R Brooks; B A McGovern; H Garan; J N Ruskin
Journal:  Br Heart J       Date:  1993-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.