Literature DB >> 1550019

Survival after implantation of the cardioverter defibrillator.

D Newman1, M J Sauve, J Herre, J J Langberg, M A Lee, C Titus, J Franklin, M M Scheinman, J C Griffin.   

Abstract

The actuarial survival of 60 consecutive recipients of the implanted cardioverter defibrillator (ICD) were compared with 120 matched concurrent medically treated patients using a case-control design. All ICD patients and controls presented with either sustained ventricular tachycardia or ventricular fibrillation. Controls were matched to ICD recipients according to 5 variables: age, left ventricular ejection fraction, arrhythmia at presentation, underlying heart disease and drug therapy status. Mean ages were 58 and 59 years in ICD patients and controls, and the average ejection fractions were 36 and 35%. Coronary artery disease was present in 75 and 79% of ICD patients and controls, respectively. During follow-up, sudden deaths were fewer in ICD recipients than in controls (5 vs 10%, p less than 0.01). At 1 and 3 years, actuarial survival was 0.89 vs 0.72 and 0.65 vs 0.49 for ICD recipients and controls. The 5-year actuarial survival curves were significantly different by the Cox proportional hazards model (p less than 0.05). It is concluded that in this retrospective case-control study, the use of the ICD in the management of patients at risk for sudden death results in improved probability of survival.

Entities:  

Mesh:

Year:  1992        PMID: 1550019     DOI: 10.1016/0002-9149(92)90789-2

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  15 in total

Review 1.  Secondary prevention of sudden death.

Authors:  R Cappato; K H Kuck
Journal:  J Interv Card Electrophysiol       Date:  2000-01       Impact factor: 1.900

Review 2.  Changing concepts of electrophysiology testing for ventricular arrhythmias.

Authors:  M Akhtar
Journal:  J Interv Card Electrophysiol       Date:  2000-01       Impact factor: 1.900

Review 3.  Evaluating AVID, CASH, CIDS, CABG-patch and MADIT: are they concordant?

Authors:  D Böcker; G Breithardt
Journal:  J Interv Card Electrophysiol       Date:  2000-01       Impact factor: 1.900

4.  Sudden Electrical Death.

Authors: 
Journal:  Curr Treat Options Cardiovasc Med       Date:  1999-06

5.  Sudden cardiac death unresponsive to implantable defibrillator therapy: an urgent target for clinicians, industry and government.

Authors:  Kelley P Anderson
Journal:  J Interv Card Electrophysiol       Date:  2005-11       Impact factor: 1.900

Review 6.  Evaluation and treatment strategies in patients at high risk of sudden death post myocardial infarction.

Authors:  R D Underwood; J Sra; M Akhtar
Journal:  Clin Cardiol       Date:  1997-09       Impact factor: 2.882

Review 7.  Cardiology--II: Treatment of heart failure and atrial fibrillation and arrhythmias.

Authors:  J McMurray; A Rankin
Journal:  BMJ       Date:  1994-12-17

Review 8.  Perspectives: does amiodarone increase non-sudden deaths? If so, why?

Authors:  A Auricchio; S Nisam; H U Klein
Journal:  J Interv Card Electrophysiol       Date:  2000-12       Impact factor: 1.900

Review 9.  The management of ventricular arrhythmias in older patients after CAST.

Authors:  W S Aronow
Journal:  Drugs Aging       Date:  1995-02       Impact factor: 3.923

10.  Potential impact of antiarrhythmic drugs versus implantable defibrillators on the management of ventricular arrhythmias: the Midlands trial of empirical amiodarone versus electrophysiologically guided intervention and cardioverter implant registry data.

Authors:  R K Pathmanathan; E W Lau; J Cooper; L Newton; J D Skehan; C J Garratt; M J Griffith
Journal:  Heart       Date:  1998-07       Impact factor: 5.994

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.