Literature DB >> 9973009

Influence of right ventricular stimulation site on left ventricular function in atrial synchronous ventricular pacing.

B Schwaab1, G Fröhlig, C Alexander, M Kindermann, N Hellwig, H Schwerdt, C M Kirsch, H Schieffer.   

Abstract

OBJECTIVES: The study investigates the correlation between left ventricular function and QRS duration obtained by alternate right ventricular pacing sites.
BACKGROUND: 1. Right ventricular apical pacing is associated with alterations of left ventricular contraction sequence. 2. A stimulation producing narrow QRS complexes is supposed to provide for better left ventricular contraction patterns.
METHODS: Fourteen patients with third degree AV block received one ventricular pacing lead in apical position. The alternate lead was attached to that site on the septum that produced the smallest QRS complex as measured from the earliest to the last deflection in any of the orthogonal Frank leads (xyz). During atrial synchronous ventricular pacing, the AV delay was optimized individually and for each stimulation site using mitral valve doppler or impedance cardiography. By radionuclide ventriculography, the phase distribution histogram of left ventricular contraction was evaluated as area under the curve (AuC); systolic function was determined as ejection fraction (EF) and as absolute ejected counts (EC) in random order. The difference (delta) in QRS duration between apical and septal stimulation (deltaxyz) was correlated with the difference in phase distribution (deltaAuC) and ejection parameters (deltaEF, deltaEC).
RESULTS: QRS duration was shorter with septal than with apical pacing in 9 out of 14 patients (64%); it was longer in 4 (29%), and no difference was seen in 1 patient. There was a significant positive correlation between the change in QRS duration (deltaxvz) and phase distribution (deltaAuC: r = 0.66393, p = 0.010) and a significant negative correlation to systolic function (deltaEF: r = 0.70931, p = 0.004; deltaEC: r = 0.74368, p = 0.002).
CONCLUSIONS: In atrial synchronous right ventricular pacing, if the AV delay is adapted individually, decreased QRS duration obtained by alternate pacing sites is significantly correlated with homogenization of left ventricular contraction and with increased systolic function in acute tests.

Entities:  

Mesh:

Year:  1999        PMID: 9973009     DOI: 10.1016/s0735-1097(98)00562-2

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  18 in total

1.  The DAVID trial and its implications: where do we go from here?

Authors:  Brian Olshansky
Journal:  Curr Cardiol Rep       Date:  2003-09       Impact factor: 2.931

Review 2.  Right ventricular pacing, mechanical dyssynchrony, and heart failure.

Authors:  Alan J Bank; Ryan M Gage; Kevin V Burns
Journal:  J Cardiovasc Transl Res       Date:  2011-12-22       Impact factor: 4.132

3.  Interventricular septal or standard apical pacing in pacing dependent patients: still a dilemma?

Authors:  Roxana Cristina Rimbas Sisu; Mircea Cinteza; Dragos Vinereanu
Journal:  Maedica (Buchar)       Date:  2010-07

4.  Comparison of the acute hemodynamic effect of right ventricular apex, outflow tract, and dual-site right ventricular pacing.

Authors:  Andrzej Rubaj; Piotr Rucinski; Tomasz Sodolski; Andrzej Bilan; Marcin Gulaj; Alicja Dabrowska-Kugacka; Andrzej Kutarski
Journal:  Ann Noninvasive Electrocardiol       Date:  2010-10       Impact factor: 1.468

Review 5.  "Dialing-in" cardiac resynchronization therapy: overcoming constraints of the coronary venous anatomy.

Authors:  Jagmeet P Singh; E Kevin Heist; Jeremy N Ruskin; J Warren Harthorne
Journal:  J Interv Card Electrophysiol       Date:  2007-01-25       Impact factor: 1.900

6.  [16th part: ventricular lead position].

Authors:  C W Israel; D Pajitnev
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2007-09

Review 7.  [Is resynchronization therapy necessary when optimizing right ventricular stimulation?].

Authors:  G Fröhlig
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-12

8.  Incidence and predictors of pacemaker-induced cardiomyopathy with comparison between apical and non-apical right ventricular pacing sites.

Authors:  Raghav Bansal; Neeraj Parakh; Anunay Gupta; Rajnish Juneja; Nitish Naik; Rakesh Yadav; Gautam Sharma; Ambuj Roy; Sunil Kumar Verma; Vinay Kumar Bahl
Journal:  J Interv Card Electrophysiol       Date:  2019-07-30       Impact factor: 1.900

9.  Evaluation of Long Term Effect of RV Apical Pacing on Global LV Function by Echocardiography.

Authors:  Narayan Chandra Sarkar; Mahendra Tilkar; Siddhant Jain; Subrata Mondal; Piyabi Sarkar; Nitin Modi
Journal:  J Clin Diagn Res       Date:  2016-03-01

10.  Intercostal muscle twitching: an unusual manifestation of extracardiac stimulation related to right ventricular outflow tract pacing.

Authors:  Okan Erdogan
Journal:  Can J Cardiol       Date:  2007-08       Impact factor: 5.223

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.