Literature DB >> 9934613

Impact of presence of abnormal wall motion on echocardiographic determination of left ventricular function with automated boundary detection technique: re-evaluation.

G C Zhang1, K Nakamura, T Tsukada, S Nakatani, M Uematsu, N Tanaka, Y Masuda, Y Yasumura, K Miyatake, M Yamagishi.   

Abstract

It is still unclear whether echocardiography with an automated boundary detection technique (ABD) can accurately determine the left ventricular (LV) volume and function particularly in the presence of LV wall asynergy. We intended to re-evaluate the reliability and application of the ABD, which was based on the acoustic quantification technique (Sonos 2500, Hewlett Packard) for the LV volume measurement in patients without or with LV wall asynergy. A total of 80 patients (mean age 56 years) who underwent left ventriculography (LVG) were divided into two groups. The group A consisted of 29 patients with normal LV wall motion and the group B consisted of 51 patients with generalized or regional LV wall motion abnormality. In group A patients, the LV end-diastolic volume (LVEDV) was 96 +/- 25 ml by ABD and 112 +/- 33 ml by LVG and those of LV end-systolic volume (LVESV) were 44 +/- 14 ml by ABD and 48 +/- 17 ml by LVG, thus resulting in the underestimation of LV volume by 12% in average. Under these conditions, the LV ejection fraction (LVEF) by ABD, 54 +/- 8%, correlated well with that by LVG, 58 +/- 7%. Although underestimation of LV volume by 17% in average also occurred in groups B (N.S.), LVEF was found to correlate well with that by LVG; 27 +/- 8% vs 30 +/- 11% (r = 0.87, SEE = 3.1%) for 21 patients with the generalized LV asynergy; 39 +/- 10% vs 39 +/- 12% (r = 0.86. SEE = 3.3%) for 30 patients with the regional LV asynergy. These results demonstrate the feasibility of the ABD in determining the LVEF, although underestimation can occur in measuring the absolute LV volume in patients with or without LV asynergy.

Entities:  

Mesh:

Year:  1998        PMID: 9934613     DOI: 10.1023/a:1006060105703

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  20 in total

1.  Estimation of left ventricular cavity area with an on-line, semiautomated echocardiographic edge detection system.

Authors:  B F Vandenberg; L S Rath; P Stuhlmuller; H E Melton; D J Skorton
Journal:  Circulation       Date:  1992-07       Impact factor: 29.690

2.  On-line assessment of ventricular function by automatic boundary detection and ultrasonic backscatter imaging.

Authors:  J E Pérez; A D Waggoner; B Barzilai; H E Melton; J G Miller; B E Sobel
Journal:  J Am Coll Cardiol       Date:  1992-02       Impact factor: 24.094

3.  Improved quantification of left ventricular function by applying signal averaging to echocardiographic acoustic quantification.

Authors:  V Mor-Avi; I E Gillesberg; C Korcarz; J Sandelski; R M Lang
Journal:  J Am Soc Echocardiogr       Date:  1995 Sep-Oct       Impact factor: 5.251

4.  Two-dimensional Fourier filtration of acoustic quantification echocardiographic images: improved reproducibility and accuracy of automated measurements of left ventricular performance.

Authors:  S Chandra; M J Garcia; A Morehead; J D Thomas
Journal:  J Am Soc Echocardiogr       Date:  1997-05       Impact factor: 5.251

5.  Quantitative three-dimensional reconstruction of left ventricular volume with complete borders detected by acoustic quantification underestimates volume.

Authors:  L Jiang; R Morrissey; M D Handschumacher; J A Vazquez de Prada; J He; M H Picard; A E Weyman; R A Levine
Journal:  Am Heart J       Date:  1996-03       Impact factor: 4.749

6.  [Feasibility of the left ventricular volume measurement by acoustic quantification method: comparison with ultrafast computed tomography].

Authors:  S Tomimoto; S Nakatani; N Tanaka; M Uematsu; S Beppu; S Nagata; S Hamada; M Takamiya; K Miyatake
Journal:  J Cardiol       Date:  1995-01       Impact factor: 3.159

7.  Quantification of left ventricular function with an automated border detection system and comparison with radionuclide ventriculography.

Authors:  P D Lindower; L Rath; J Preslar; T L Burns; K Rezai; B F Vandenberg
Journal:  Am J Cardiol       Date:  1994-01-15       Impact factor: 2.778

8.  Automated assessment of ventricular volume and function by echocardiography: validation of automated border detection.

Authors:  R L Morrissey; S C Siu; J L Guerrero; J B Newell; A E Weyman; M H Picard
Journal:  J Am Soc Echocardiogr       Date:  1994 Mar-Apr       Impact factor: 5.251

9.  Left atrial size and function: assessment using echocardiographic automatic boundary detection.

Authors:  P B Clarkson; N M Wheeldon; P O Lim; S D Pringle; T M MacDonald
Journal:  Br Heart J       Date:  1995-12

10.  On-line estimation of changes in left ventricular stroke volume by transesophageal echocardiographic automated border detection in patients undergoing coronary artery bypass grafting.

Authors:  J Gorcsan; T A Gasior; W A Mandarino; L G Deneault; B G Hattler; M R Pinsky
Journal:  Am J Cardiol       Date:  1993-09-15       Impact factor: 2.778

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.