Literature DB >> 8296743

Quantification of left ventricular function with an automated border detection system and comparison with radionuclide ventriculography.

P D Lindower1, L Rath, J Preslar, T L Burns, K Rezai, B F Vandenberg.   

Abstract

Quantification of 2-dimensional echocardiograms with a recently developed automated border detection (ABD) system provides on-line estimation of left ventricular (LV) function. Previous studies showed that short-axis cavity area measurements with the ABD system approximate manually traced cavity areas obtained with conventional 2-dimensional echocardiography. Further clinical validation needs a comparison of LV function between the ABD system and established methods. Fractional area change and ejection fraction measured by the ABD system were compared with ejection fraction measured by radionuclide ventriculography. Echocardiographic measurements were obtained from LV short-axis views at the level of the papillary muscles. Calculation of ejection fraction by the ABD system was based on an algorithm using a modified ellipsoid model. Forty-six patients underwent echocardiography on the same day as radionuclide ventriculography. Patients were included in the study if > or = 75% of the endocardium was visualized with conventional 2-dimensional echocardiography. Twenty-seven of 46 patients (59%) had a technically adequate, conventional echocardiogram. Fractional area change with the ABD system was highly correlated with ejection fraction from radionuclide ventriculography (r = 0.92; SEE 8.4%). Ejection fraction determined by the ABD system and radionuclide ventriculography also showed a strong linear relation in the 23 patients without severe wall motion abnormality (r = 0.90; SEE 9.5%). It is concluded that LV function measurements by the ABD system and radionuclide ventriculography have a strong linear relation.

Entities:  

Mesh:

Year:  1994        PMID: 8296743     DOI: 10.1016/0002-9149(94)90214-3

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  7 in total

Review 1.  Quantitative assessment of mitral insufficiency: its advantages and disadvantages.

Authors:  Anna Paszczuk; Susan E Wiegers
Journal:  Heart Fail Rev       Date:  2006-09       Impact factor: 4.214

2.  Impact of presence of abnormal wall motion on echocardiographic determination of left ventricular function with automated boundary detection technique: re-evaluation.

Authors:  G C Zhang; K Nakamura; T Tsukada; S Nakatani; M Uematsu; N Tanaka; Y Masuda; Y Yasumura; K Miyatake; M Yamagishi
Journal:  Int J Card Imaging       Date:  1998-08

Review 3.  Myocardial perfusion imaging versus two-dimensional echocardiography: comparative value in the diagnosis of coronary artery disease.

Authors:  M S Verani
Journal:  J Nucl Cardiol       Date:  1994 Jul-Aug       Impact factor: 5.952

4.  Assessment of left ventricular function: comparison between radionuclide angiography and semiquantitative two-dimensional echocardiographic analysis.

Authors:  M Gottsauner-Wolf; J Schedlmayer-Duit; G Porenta; M Gwechenberger; K Huber; D Glogar; P Probst; H Sochor
Journal:  Eur J Nucl Med       Date:  1996-12

5.  Detection of diastolic dysfunction: acoustic quantification (AQ) in comparison to Doppler echocardiography.

Authors:  B Hausmann; S Muurling; C Stauch; A Haverich; S Hirt; R Simon
Journal:  Int J Card Imaging       Date:  1997-08

6.  Dynamic on-line quantification of biventricular function with acoustic quantification (AQ). Validation, reproducibility and normal values of a new echocardiographic approach.

Authors:  B Hausmann; S Muurling; R Simon
Journal:  Int J Card Imaging       Date:  1997-12

7.  Left ventricular ejection fraction measurements: accuracy and prognostic implications in a large population of patients with known or suspected ischemic heart disease.

Authors:  Alessia Gimelli; Patrizia Landi; Paolo Marraccini; Rosa Sicari; Paolo Frumento; Antonio L'Abbate; Daniele Rovai
Journal:  Int J Cardiovasc Imaging       Date:  2008-07-09       Impact factor: 2.357

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.