Automated assessment of ventricular volume and function by echocardiography: validation of automated border detection.

R L Morrissey1, S C Siu, J L Guerrero, J B Newell, A E Weyman, M H Picard.   

Abstract

To determine the utility of a new on-line echocardiographic automated border detection (ABD) algorithm in assessing ventricular volume and ejection fraction, an optimal model was studied. This open-chest canine model allowed continuous measurement of actual left ventricular volume. In four dogs, true end-systolic and end-diastolic volume and ejection fraction were compared with those obtained by two-dimensional echocardiography with an automated method calculated from a border detection algorithm to define left ventricular endocardium and the single-plane Simpson method to calculate volume. Left ventricular volumes that used manual, off-line tracings of the left ventricle by two-dimensional echocardiograms and the single-plane Simpson method were compared. The automated echocardiographic volumes correlated with true volumes (y = 0.7x + 8.9; standard error of the estimate = 13.5 cc; r = 0.81). A significant mean underestimation of 11 +/- 15 cc was noted (p < 0.0001). Volumes obtained from the manual tracings of left ventricular endocardial contours also correlated well with true volumes (y = 0.89x + 4; standard error of the estimate = 6.7 cc; r = 0.96). However, the 3 +/- 7 underestimation was significantly lower than the error of the ABD method (p = 0.00005). Both on-line ABD and off-line ejection fractions correlated well with true ejection fractions (r = 0.94 and 0.96, respectively). There was no statistically significant difference between the mean errors of the ABD or manually derived ejection fractions. In the setting of optimal left ventricular imaging, the on-line and rapid features of this automated method make it potentially useful for quickly obtaining left ventricular volumes and ejection fraction.

Entities:  

Mesh:

Year:  1994        PMID: 8185955     DOI: 10.1016/s0894-7317(14)80116-8

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  3 in total

1.  Impact of presence of abnormal wall motion on echocardiographic determination of left ventricular function with automated boundary detection technique: re-evaluation.

Authors:  G C Zhang; K Nakamura; T Tsukada; S Nakatani; M Uematsu; N Tanaka; Y Masuda; Y Yasumura; K Miyatake; M Yamagishi
Journal:  Int J Card Imaging       Date:  1998-08

2.  Semi-automated echocardiographic quantification of right ventricular size and function.

Authors:  Diego Medvedofsky; Karima Addetia; Jamie Hamilton; Javier Leon Jimenez; Roberto M Lang; Victor Mor-Avi
Journal:  Int J Cardiovasc Imaging       Date:  2015-05-07       Impact factor: 2.357

3.  Clinical outcomes of acute myocarditis in childhood.

Authors:  K J Lee; B W McCrindle; D J Bohn; G J Wilson; G P Taylor; R M Freedom; J F Smallhorn; L N Benson
Journal:  Heart       Date:  1999-08       Impact factor: 5.994

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.