Literature DB >> 9926947

Hydroxyapatite coating versus cemented fixation of the tibial component in total knee arthroplasty: prospective randomized comparison of hydroxyapatite-coated and cemented tibial components with 5-year follow-up using radiostereometry.

K G Nilsson1, J Kärrholm, L Carlsson, T Dalén.   

Abstract

Fifty-three consecutive patients (57 knees; mean age, 69 years) entered a prospective randomized study to compare the fixation of hydroxyapatite (HA)-coated (29 knees) with cemented (28 knees) tibial components in the Tricon II total knee arthroplasty. The quality of the fixation during 5 years postoperatively was evaluated with radiostereometric analysis (RSA). Three HA-coated implants were revised: 2 owing to infection, and 1 owing to early delamination of the coating and clinical loosening. Eight patients (9 knees) died, 1 patient sustained a stroke, and 1 patient refused investigations after 1 year. In the 40 patients (19 HA-coated, 21 cemented) remaining at 5 years, the magnitude of the micromotion between the HA-coated and cemented groups did not differ. The HA-coated implants displayed most of the migration within the initial 3 months then stabilized, whereas the cemented implants showed an initially lower, but over time continuously increasing migration. Between 1 and 2 years, 4 of 24 HA-coated and 10 of 23 cemented implants migrated >0.2 mm and were categorized unstable, which has been shown to have a prognostic value as regards future aseptic loosening. Progressive radiolucent lines developed in 2 cemented knees, which both were categorized unstable. If HA-coated implants can sustain the forces that threaten the fixation in the early period after implantation, a strong and enduring fixation may be obtained.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9926947     DOI: 10.1016/s0883-5403(99)90196-1

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  28 in total

1.  Long lasting outcome of hydroxyapatite-coated implants in primary knee arthroplasty: a continuous series of two hundred and seventy total knee arthroplasties at fifteen to twenty two years of clinical follow-up.

Authors:  Jean-Alain Epinette
Journal:  Int Orthop       Date:  2014-01-03       Impact factor: 3.075

2.  Prospective study of the cementless "New Wave" total knee mobile-bearing arthroplasty: 8-year follow-up.

Authors:  Xavier Normand; Jean-Louis Pinçon; Jean-Marie Ragot; Régis Verdier; Thierry Aslanian
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-05-25

3.  Roentgen stereophotogrammetric analysis: an effective tool to predict implant survival after an all-poly unicompartmental knee arthroplasty-a 10 year follow-up study.

Authors:  Danilo Bruni; Laura Bragonzoni; Michele Gagliardi; Marco Bontempi; Ibrahim Akkawi; Giovanni Francesco Raspugli; Francesco Iacono; Silvio Patella; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-11       Impact factor: 4.342

4.  Cemented versus cementless fixation in total knee arthroplasty.

Authors:  Fabrizio Matassi; Christian Carulli; Roberto Civinini; Massimo Innocenti
Journal:  Joints       Date:  2014-01-08

5.  Prospective randomised clinical trial assessing subsidence and rotation, using radiostereometric analysis, of two modular cementless femoral stems (Global K2 and Apex).

Authors:  Mark Edmondson; Jay Ebert; Oscar Nivbrant; David Wood
Journal:  J Orthop       Date:  2014-04-22

6.  Preoperative gait patterns and BMI are associated with tibial component migration.

Authors:  Janie L Astephen Wilson; David A J Wilson; Michael J Dunbar; Kevin J Deluzio
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

7.  Uncemented or cemented femoral components work equally well in total knee arthroplasty.

Authors:  Anders Henricson; Radek Wojtowicz; Kjell G Nilsson; Sead Crnalic
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-25       Impact factor: 4.342

8.  Effect of bioactive coating of the tibial component on migration pattern in uncemented total knee arthroplasty: a randomized RSA study of 14 knees presented according to new RSA-guidelines.

Authors:  M Therbo; B Lund; K-E Jensen; H M Schrøder
Journal:  J Orthop Traumatol       Date:  2008-05-10

9.  Clinical Evaluation of Efficacy and Performance of All-Poly Tibial Freedom® Total Knee System for Treating Osteoarthritis Patients: Three-Year Follow Up Study.

Authors:  Avatar Singh; Kanwar Kulwinder Singh
Journal:  J Clin Diagn Res       Date:  2017-09-01

10.  Does a new knee design perform as well as the design it replaces?

Authors:  M Molt; P Ljung; S Toksvig-Larsen
Journal:  Bone Joint Res       Date:  2012-12-01       Impact factor: 5.853

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.