Literature DB >> 9926783

The evolving practice pattern of the breast surgeon with disappearance of open biopsy for nonpalpable lesions.

V J Zannis1, K M Aliano.   

Abstract

BACKGROUND: Recent advances in technology have prompted growth in the surgeon's armamentarium for breast biopsy. For nonpalpable, mammographically detected lesions, the options include stereotactic needle/wire localization and open biopsy (SNL/OBx), stereotactic needle core biopsy (SNCB), and directional, vacuum-assisted biopsy (VAB; Mammotome).
METHODS: A review of 372 patients with 424 breast lesions biopsied by the same surgeon between January 1993 and August 1997 was performed.
RESULTS: SNCB and VAB procedures were less invasive and less morbid than SNL/OBx. Vacuum-assisted biopsy was superior to SNCB for sampling efficiency, with 74% of microcalcifications removed compared with 20% (P <0.0001). Additionally, underestimation of disease was seen with the SNCB technique, but not with VAB. Follow-up mammography found no false negative biopsies in any group. Over the 56 consecutive months, VAB progressively replaced SNL/OBx and SNCB as the procedure of choice.
CONCLUSION: A breast surgeon can use VAB to replace open biopsy and core needle procedures for the initial biopsy of nonpalpable breast lesions.

Entities:  

Mesh:

Year:  1998        PMID: 9926783     DOI: 10.1016/s0002-9610(98)00265-7

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  4 in total

1.  Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips.

Authors:  R Schulz-Wendtland; P Dankerl; G Dilbat; M Bani; P A Fasching; K Heusinger; M P Lux; C R Loehberg; S M Jud; C Rauh; C M Bayer; M W Beckmann; D L Wachter; M Uder; M Meier-Meitinger; B Brehm
Journal:  Geburtshilfe Frauenheilkd       Date:  2015-01       Impact factor: 2.915

Review 2.  The Evolving Role of Vacuum Assisted Biopsy of the Breast: A Progression from Fine-Needle Aspiration Biopsy.

Authors:  Ian C Bennett; Apoorva Saboo
Journal:  World J Surg       Date:  2019-04       Impact factor: 3.352

3.  Evaluation of Newly Adapted Clip Marker System in Ultrasound-Guided Core Needle Biopsy for Suspicion of Breast Cancer.

Authors:  R Schulz-Wendtland; P Dankerl; G Dilbat; M Bani; P A Fasching; K Heusinger; M P Lux; C R Loehberg; S M Jud; C Rauh; C M Bayer; M W Beckmann; M Uder; M Meier-Meitinger; B Brehm
Journal:  Geburtshilfe Frauenheilkd       Date:  2013-11       Impact factor: 2.915

4.  Horizontal Rotary Cutting Technique for Skin Injury Avoidance in Superficial Benign Breast Masses.

Authors:  Ren-Feng Song; Yu-Xia Jiang; Jian-Chun Cui; Xue-Wei Yu; Yang Gao; Li Li; Xiao-Hua Pei
Journal:  Int J Gen Med       Date:  2021-04-19
  4 in total