Literature DB >> 9917592

Importance of a thin cement mantle. Autopsy studies of eight hips.

K Kawate1, W J Maloney, C R Bragdon, S A Biggs, M Jasty, W H Harris.   

Abstract

The question whether thin cement mantles around cemented femoral components led to an increased frequency of cracks in the cement was asked. Microscopically, multiple cross sections of eight femurs retrieved at autopsy from clinically successful total hip replacements after prolonged in vivo service containing well fixed Harris Design 2 cemented femoral components were studied. None of the components were loose by radiographic criteria. All were fixed solidly when loaded in vitro in simulated stair climbing and gait, as assessed by high resolution micromotion sensors. The specimens were sectioned transversely at 5-mm increments. The cross sections were examined under a dissecting microscope at x 100. A thin mantle arbitrarily was defined as a mantle of less than 1 mm in thickness. The analysis of the contact radiographs showed that the routine anteroposterior and lateral radiographs underestimated the prevalence of thin cement mantles and mantle defects. Although overall on all the cross sections 9% of the aggregated cement mantles was classified as having thin cement, 92 of the 101 cement cracks occurred in areas of the mantles that were less than 1 mm thick.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9917592     DOI: 10.1097/00003086-199810000-00008

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  10 in total

1.  Multi-technique characterization of retrieved bone cement from revised total hip arthroplasties.

Authors:  T Eliades; J S Papadopulos; G Eliades; N Silikas; D C Watts
Journal:  J Mater Sci Mater Med       Date:  2003-11       Impact factor: 3.896

2.  Stem-cement porosity may explain early loosening of cemented femoral hip components: experimental-computational in vitro study.

Authors:  Kenneth A Mann; Leatha A Damron; Mark A Miller; Amos Race; Michael T Clarke; Richard J Cleary
Journal:  J Orthop Res       Date:  2007-03       Impact factor: 3.494

3.  Using 'subcement' to simulate the long-term fatigue response of cemented femoral stems in a cadaver model: could a novel preclinical screening test have caught the Exeter matt problem?

Authors:  A Race; M A Miller; K A Mann
Journal:  Proc Inst Mech Eng H       Date:  2010       Impact factor: 1.617

4.  Direct evidence of "damage accumulation" in cement mantles surrounding femoral hip stems retrieved at autopsy: cement damage correlates with duration of use and BMI.

Authors:  A Race; M A Miller; T H Izant; K A Mann
Journal:  J Biomech       Date:  2011-07-28       Impact factor: 2.712

5.  Quality of the femoral cement mantle in total hip arthroplasty using the direct anterior hip approach.

Authors:  Eustathios Kenanidis; Rajiv Kaila; Lazaros Poultsides; Eleftherios Tsiridis; Panayiotis Christofilopoulos
Journal:  Arthroplast Today       Date:  2020-06-22

6.  The posterior approach reduces the risk of thin cement mantles with a straight femoral stem design.

Authors:  Gavin J Macpherson; Christian Hank; Michael Schneider; Morag Trayner; Robert Elton; Colin R Howie; Steffen J Breusch
Journal:  Acta Orthop       Date:  2010-06       Impact factor: 3.717

7.  Biomechanical behaviour of a French femoral component with thin cement mantle: The 'French paradox' may not be a paradox after all.

Authors:  Y Numata; A Kaneuji; L Kerboull; E Takahashi; T Ichiseki; K Fukui; J Tsujioka; N Kawahara
Journal:  Bone Joint Res       Date:  2018-08-04       Impact factor: 5.853

8.  Fixation of the cemented stem: clinical relevance of the porosity and thickness of the cement mantle.

Authors:  Philippe Hernigou; Gildasio Daltro; Charles Henri Flouzat Lachaniette; Xavier Roussignol; Martin Mukisi Mukasa; Alexandre Poignard
Journal:  Open Orthop J       Date:  2009-02-12

9.  Minimum ten-year outcome of a triple-tapered femoral stem implanted with line-to-line cementing technique.

Authors:  Hirotsugu Ohashi; Satoshi Iida; Izumi Minato
Journal:  BMC Musculoskelet Disord       Date:  2021-06-30       Impact factor: 2.362

10.  The influence of cement thickness on stem subsidence and cement creep in a collarless polished tapered stem: When are thick cement mantles detrimental?

Authors:  E Takahashi; A Kaneuji; R Tsuda; Y Numata; T Ichiseki; K Fukui; N Kawahara
Journal:  Bone Joint Res       Date:  2017-05       Impact factor: 5.853

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.