Literature DB >> 1449935

Effect of cup geometry and the presence of cement on acetabular component fixation.

J Timperley1, G Bannister, G Gie, P Ring, R Ling.   

Abstract

Two series of implanted conical, polyethylene Ring cups were studied clinically and radiographically. In one series the cups were uncemented while in the second cement was used. The results using cemented conical cups were then compared with results using a cemented cup of hemispherical design to study the effect of cup geometry. At 7-8 years a total of 3.8% of the cemented conical series and 2.9% of the uncemented were revised for aseptic loosening. At 9 years survivorship was identical. Migration of the sockets occurred in approximately 25% of both series and was directly related to cup cover of less than 80% (P < 0.001). The series of cemented hemispherical cups were reviewed after an identical period. Although the numbers revised for loosening were comparable in this and the cemented conical group, radiological migration was statistically greater in the latter (P < 0.001). Alternative methods of socket preparation and cement technique were thought to be the most likely explanation for the observed differences.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1449935     DOI: 10.1007/bf00420054

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  12 in total

1.  Cementless acetabular components.

Authors:  C A Engh; W L Griffin; C L Marx
Journal:  J Bone Joint Surg Br       Date:  1990-01

2.  The correlation between the roentgenographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties.

Authors:  J P Hodgkinson; P Shelley; B M Wroblewski
Journal:  Clin Orthop Relat Res       Date:  1988-03       Impact factor: 4.176

3.  Mittelmeier ceramic total hip arthroplasty. A retrospective study.

Authors:  J F O'Leary; T H Mallory; T J Kraus; A V Lombardi; C L Lye
Journal:  J Arthroplasty       Date:  1988       Impact factor: 4.757

4.  Survivorship analysis of 1,041 Charnley total hip arthroplasties.

Authors:  W J Hozack; R H Rothman; R E Booth; R A Balderston; J C Cohn; G T Pickens
Journal:  J Arthroplasty       Date:  1990-03       Impact factor: 4.757

5.  Evaluation of cementless acetabular component migration. An experimental study.

Authors:  P Massin; L Schmidt; C A Engh
Journal:  J Arthroplasty       Date:  1989-09       Impact factor: 4.757

6.  Nine-year follow-up of the cementless Ring hip.

Authors:  P Albrecht-Olsen; T Owen-Falkenberg; P Burgaard; P B Andersen
Journal:  Acta Orthop Scand       Date:  1989-02

7.  Cementless acetabular replacement using a pegged polyethylene prosthesis.

Authors:  K C Bertin; M A Freeman; E Morscher; A Oeri; P A Ring
Journal:  Arch Orthop Trauma Surg       Date:  1985

8.  Survivorship of total hip replacements.

Authors:  H S Dobbs
Journal:  J Bone Joint Surg Br       Date:  1980-05

9.  Threaded cup acetabuloplasty. Early clinical experience.

Authors:  D M Apel; D G Smith; C M Schwartz; W G Paprosky
Journal:  Clin Orthop Relat Res       Date:  1989-04       Impact factor: 4.176

10.  The bone-cement interface in hip arthroplasty. A histologic and enzyme study of stable components.

Authors:  L Linder; A S Carlsson
Journal:  Acta Orthop Scand       Date:  1986-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.