Clinical performance of orthodontic brackets and adhesive systems: a randomized clinical trial.

S Sunna1, W P Rock.   

Abstract

The aim of the study was to evaluate and compare the clinical performance of adhesive precoated brackets (APC) with that of two types of uncoated bracket bases, Straight-Wire and Dyna-Lock, bonded using two types of orthodontic adhesives, Transbond XT, and Right-On. Forty consecutive orthodontic patients entered the trial and 607 brackets were bonded. The incidence and site of first time bond failures were recorded over a period of 1 year. The time required for bonding was also recorded. The overall bond failure rate was 6.6 per cent. There were no significant differences between the failure rates of the five groups, or between the upper and lower arch. However, significantly more brackets failed on the left side than on the right. Premolar brackets were lost most often, whilst incisor brackets failed least. No association was found between bond failure and time elapsed since bonding. Bonding time was least with Right-On adhesive. There were no significant differences between bonding times using APC or Transbond. Results of the present study conflict with those of a previous ex vivo study by the authors, using the same materials and bonding technique. Suggested reasons for this are discussed.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9884779     DOI: 10.1093/ortho/25.4.283

Source DB:  PubMed          Journal:  Br J Orthod        ISSN: 0301-228X


  26 in total

1.  Shear bond strength of rebonded brackets after removal of adhesives with Er,Cr:YSGG laser.

Authors:  Katsuyuki Ishida; Toshiya Endo; Koichi Shinkai; Yoshiroh Katoh
Journal:  Odontology       Date:  2011-05-07       Impact factor: 2.634

2.  Clinical performance of precoated brackets and self-etch bonding technique: a prospective comparative study.

Authors:  Ezgi Atik; Hande Gorucu-Coskuner; Tulin Taner
Journal:  Clin Oral Investig       Date:  2018-11-30       Impact factor: 3.573

3.  Adhesive precoated bracket systems and operator coated bracket systems: Is there any difference? A systematic review and meta-analysis.

Authors:  Ahmed Mohamed Alakttash; Mohamed Fawzi; David Bearn
Journal:  Angle Orthod       Date:  2018-12-17       Impact factor: 2.079

4.  Comparative Evaluation of Two Bis-GMA Based Orthodontic Bonding Adhesives - A Randomized Clinical Trial.

Authors:  Christine Samantha; Shantha Sundari; Shyamala Chandrasekhar; Gautham Sivamurty; Saravana Dinesh
Journal:  J Clin Diagn Res       Date:  2017-04-01

5.  Failure patterns of different bracket systems and their influence on treatment duration: A retrospective cohort study.

Authors:  Dimitrios Stasinopoulos; Spyridon N Papageorgiou; Frank Kirsch; Nikolaos Daratsianos; Andreas Jäger; Christoph Bourauel
Journal:  Angle Orthod       Date:  2018-02-02       Impact factor: 2.079

6.  Clinical effect of reducing curing times with high-intensity LED lights.

Authors:  Justin D Ward; Bethany J Wolf; Luis P Leite; Jing Zhou
Journal:  Angle Orthod       Date:  2015-03-11       Impact factor: 2.079

Review 7.  Enamel etching for bonding fixed orthodontic braces.

Authors:  Haikun Hu; Chunjie Li; Fan Li; Jianwei Chen; Jianfeng Sun; Shujuan Zou; Andrew Sandham; Qiang Xu; Philip Riley; Qingsong Ye
Journal:  Cochrane Database Syst Rev       Date:  2013-11-25

8.  Survival analysis of brackets and tubes: A twelve-month assessment.

Authors:  Min-Ho Jung
Journal:  Angle Orthod       Date:  2014-03-25       Impact factor: 2.079

9.  Clinical bond failure rates of adhesive precoated self-ligating brackets using a self-etching primer.

Authors:  Mete Ozer; Mehmet Bayram; Cagri Dincyurek; Fuat Tokalak
Journal:  Angle Orthod       Date:  2013-07-02       Impact factor: 2.079

10.  The effect of different soft drinks on the shear bond strength of orthodontic brackets.

Authors:  M Omid Khoda; F Heravi; H Shafaee; H Mollahassani
Journal:  J Dent (Tehran)       Date:  2012-06-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.