Literature DB >> 24272130

Enamel etching for bonding fixed orthodontic braces.

Haikun Hu1, Chunjie Li, Fan Li, Jianwei Chen, Jianfeng Sun, Shujuan Zou, Andrew Sandham, Qiang Xu, Philip Riley, Qingsong Ye.   

Abstract

BACKGROUND: Acid etching of tooth surfaces to promote the bonding of orthodontic attachments to the enamel has been a routine procedure in orthodontic treatment since the 1960s. Various types of orthodontic etchants and etching techniques have been introduced in the past five decades. Although a large amount of information on this topic has been published, there is a significant lack of consensus regarding the clinical effects of different dental etchants and etching techniques.
OBJECTIVES: To compare the effects of different dental etchants and different etching techniques for the bonding of fixed orthodontic appliances. SEARCH
METHODS: We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 8 March 2013), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 2), MEDLINE via OVID (to 8 March 2013), EMBASE via OVID (to 8 March 2013), Chinese Biomedical Literature Database (to 12 March 2011), the WHO International Clinical Trials Registry Platform (to 8 March 2013) and the National Institutes of Health Clinical Trials Registry (to 8 March 2013). A handsearching group updated the handsearching of journals, carried out as part of the Cochrane Worldwide Handsearching Programme, to the most current issue. There were no restrictions regarding language or date of publication. SELECTION CRITERIA: Randomized controlled trials (RCTs) comparing different etching materials, or different etching techniques using the same etchants, for the bonding of fixed orthodontic brackets to incisors, canines and premolars in children and adults. DATA COLLECTION AND ANALYSIS: Two review authors extracted data and assessed the risk of bias of included studies independently and in duplicate. We resolved disagreements by discussion among the review team. We contacted the corresponding authors of the included studies to obtain additional information, if necessary. MAIN
RESULTS: We included 13 studies randomizing 417 participants with 7184 teeth/brackets. We assessed two studies (15%) as being at low risk of bias, 10 studies (77%) as being at high risk of bias and one study (8%) as being at unclear risk of bias. Self etching primers (SEPs) versus conventional etchantsEleven studies compared the effects of SEPs with conventional etchants. Only five of these studies (three of split-mouth design and two of parallel design) reported data at the participant level, with the remaining studies reporting at the tooth level, thus ignoring clustering/the paired nature of the data. A meta-analysis of these five studies, with follow-up ranging from 5 to 37 months, provided low-quality evidence that was insufficient to determine whether or not there is a difference in bond failure rate between SEPs and convention etchants (risk ratio 1.14; 95% confidence interval (CI) 0.75 to 1.73; 221 participants). The uncertainty in the CI includes both no effect and appreciable benefit and harm. Subgroup analysis did not show a difference between split-mouth and parallel studies.There were no data available to allow assessment of the outcomes: decalcification, participant satisfaction and cost-effectiveness. One study reported decalcification, but only at the tooth level. SEPs versus SEPsTwo studies compared two different SEPs. Both studies reported bond failure rate, with one of the studies also reporting decalcification. However, as both studies reported outcomes only at the tooth level, there were no data available to evaluate the superiority of any of the SEPs over the others investigated with regards to any of the outcomes of this review.We did not find any eligible studies evaluating different etching materials (e.g. phosphoric acid, polyacrylic acid, maleic acid), concentrations or etching times. AUTHORS'
CONCLUSIONS: We found low-quality evidence that was insufficient to conclude whether or not there is a difference in bond failure rate between SEPs and conventional etching systems when bonding fixed orthodontic appliances over a 5- to 37-month follow-up. Insufficient data were also available to allow any conclusions to be formed regarding the superiority of SEPs or conventional etching for the outcomes: decalcification, participant satisfaction and cost-effectiveness, or regarding the superiority of different etching materials, concentrations or etching times, or of any one SEP over another. Further well-designed RCTs on this topic are needed to provide more evidence in order to answer these clinical questions.

Entities:  

Mesh:

Year:  2013        PMID: 24272130      PMCID: PMC6494434          DOI: 10.1002/14651858.CD005516.pub2

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  59 in total

1.  Clinical evaluation of bond failure rates with a new self-etching primer.

Authors:  Shadow Asgari; Anna Salas; Jeryl English; John Powers
Journal:  J Clin Orthod       Date:  2002-12

2.  Laser etching of teeth for orthodontic bracket placement: a preliminary clinical study.

Authors:  D P Roberts-Harry
Journal:  Lasers Surg Med       Date:  1992       Impact factor: 4.025

3.  Bonding of stainless steel brackets to enamel with a new self-etching primer.

Authors:  Ryan W Arnold; Edward C Combe; John H Warford
Journal:  Am J Orthod Dentofacial Orthop       Date:  2002-09       Impact factor: 2.650

4.  A simple method of increasing the adhesion of acrylic filling materials to enamel surfaces.

Authors:  M G BUONOCORE
Journal:  J Dent Res       Date:  1955-12       Impact factor: 6.116

5.  Grading quality of evidence and strength of recommendations.

Authors:  David Atkins; Dana Best; Peter A Briss; Martin Eccles; Yngve Falck-Ytter; Signe Flottorp; Gordon H Guyatt; Robin T Harbour; Margaret C Haugh; David Henry; Suzanne Hill; Roman Jaeschke; Gillian Leng; Alessandro Liberati; Nicola Magrini; James Mason; Philippa Middleton; Jacek Mrukowicz; Dianne O'Connell; Andrew D Oxman; Bob Phillips; Holger J Schünemann; Tessa Tan-Torres Edejer; Helena Varonen; Gunn E Vist; John W Williams; Stephanie Zaza
Journal:  BMJ       Date:  2004-06-19

6.  Six and 12 months' evaluation of a self-etching primer versus two-stage etch and prime for orthodontic bonding: a randomized clinical trial.

Authors:  Y D Aljubouri; D T Millett; W H Gilmour
Journal:  Eur J Orthod       Date:  2004-12       Impact factor: 3.075

7.  Effect of a self-etch primer/adhesive on the shear bond strength of orthodontic brackets.

Authors:  S E Bishara; L VonWald; J F Laffoon; J J Warren
Journal:  Am J Orthod Dentofacial Orthop       Date:  2001-06       Impact factor: 2.650

8.  In vivo bracket retention comparison of a resin-modified glass ionomer cement and a resin-based bracket adhesive system after a year.

Authors:  David J Hegarty; Tatiana V Macfarlane
Journal:  Am J Orthod Dentofacial Orthop       Date:  2002-05       Impact factor: 2.650

9.  An in vivo investigation into bond failure rates with a new self-etching primer system.

Authors:  Anthony J Ireland; Helen Knight; Martyn Sherriff
Journal:  Am J Orthod Dentofacial Orthop       Date:  2003-09       Impact factor: 2.650

Review 10.  Adhesives for fixed orthodontic brackets.

Authors:  N A Mandall; D T Millett; C R Mattick; J Hickman; T V Macfarlane; H V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2003
View more
  3 in total

1.  Resistance of bonded premolars to four artificial ageing models post enamel conditioning with a novel calcium-phosphate paste.

Authors:  Ali I Ibrahim; Noor R Al-Hasani; Van P Thompson; Sanjukta Deb
Journal:  J Clin Exp Dent       Date:  2020-04-01

2.  Cluster Randomised Trials in Cochrane Reviews: Evaluation of Methodological and Reporting Practice.

Authors:  Marty Richardson; Paul Garner; Sarah Donegan
Journal:  PLoS One       Date:  2016-03-16       Impact factor: 3.240

3.  A Clinical Comparison of Failure Rates of Metallic and Ceramic Brackets: A Twelve-Month Study.

Authors:  Tomasz Ogiński; Beata Kawala; Marcin Mikulewicz; Joanna Antoszewska-Smith
Journal:  Biomed Res Int       Date:  2020-01-10       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.